All Categories
History
Relatively Fast Response
Product
Single point load cell PW25Handling Company
Hottinger Brüel & KjærCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Nonlinearity dlin | Static critical lateral stress Elq | Limit load (20mm away from center) EL | Permissible overload (up to 120mm away from center) | Allowable temperature range Btu | Allowable dynamic load | Accuracy class | Breaking load | Temperature compensation range BT | Minimum load output return MDLOR | Ratio of minimum verification scale Y | Minimum verification scale vmin | Maximum loading surface | Deflection amount at maximum capacity load (approximate) snom | Maximum capacity Emax | Maximum applied voltage | Maximum load cell division number nLC | Temperature effect on sensitivity TKc | Sensitivity Cn | Natural frequency (approximate) | Reference bridge applied voltage Uref | Output resistance R0 | Input resistance RLC | Eccentricity (off-center) error | Storage temperature range Btl | Bridge applied voltage range BU | Hysteresis error dhy | Temperature effect on zero point TK0 | Zero point | Insulation resistance Ris at 100VDC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PW25 |
Available upon quote |
±0.0166 (% of Cn) (Typical value for nonlinearity. These combined values meet the cumulative error requirements specified in OIML R60) |
200 (% of Emax) |
1,000 |
EU 150 (% of Emax) |
-10~+50 (+14~+122) ℃ (℉) |
Maximum 20mm away from center Fsrel: 70 |
C3 Multi-Range (MR) |
Maximum 20mm away from center Ed: >1,000 (% of Emax) |
-10~+40 (+14~+104) ℃ (℉) |
±0.0166 (% of Cn) |
10,000 |
1/2g |
400×400mm |
0.19mm |
10/20kg |
15V |
3,000 |
|
2.0±0.2mV/V |
210Hz |
5V |
300~500Ω |
300~500Ω |
±0.0233 (% of Cn) (according to OIML R76) |
-25~+70 (-13~+158) ℃ (℉) |
1~12V |
±0.0166 (% of Cn) (Typical value for hysteresis error. These combined values meet the cumulative error requirements specified in OIML R60) |
±0.0140 (% of Cn/10K) |
0±0.1mV/V |
>1GΩ |
|
PW25P |
Available upon quote |
±0.0166 (% of Cn) (Typical value for nonlinearity. These combined values meet the cumulative error requirements specified in OIML R60) |
200 (% of Emax) |
1,000 |
150 (% of Emax) |
-10~+50℃ |
Maximum 50mm away from center Frb: 70 |
C3MR |
Ed: >1,500 (% of Emax) |
-10~+40℃ |
±0.0166 (% of Cn) |
10,000 |
1/2g |
400×400mm |
0.19/0.18mm (When the load is applied at Emax at the center of gravity of the load cell) |
10/20kg |
15V |
3,000 |
|
2.0±0.2mV/V |
210/315Hz |
5V |
300~500Ω |
300~500Ω |
≦233ppm |
-25~+85℃ |
1~12V |
±0.0166 (% of Cn) (Typical value for hysteresis error. These combined values meet the cumulative error requirements specified in OIML R60) |
±0.0140 (% of Cn/10K) |
0±0.1mV/V |
>1GΩ |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.