Positive displacement gear flow meter VC series-VC0.025
Positive displacement gear flow meter VC series-Nippon Mekuman Co., Ltd.

Positive displacement gear flow meter VC series
Nippon Mekuman Co., Ltd.


About This Product

■Operating principle ・The measuring gear rotates according to the flow of fluid using the operating principle of a gear motor. ・The gear rotates without contact with the measurement chamber. There are two types of bearings: low-friction ball bearings and plain bearings. ・Two sensors installed inside the cover detect gear rotation without contact. The sensor section and measurement section are separated by an oil-resistant non-magnetic plate. - When the gear moves one pitch, the sensor outputs a pulse signal, which corresponds to the volume value of one tooth. ・The output signal is converted into a square wave by the preamplifier. - A/B 2-phase pulse output provides high resolution and allows the direction of fluid flow to be determined. ■Product features ・Optimal measurements can be performed by selecting the housing material and bearing type according to the fluid specifications. - Sizes are categorized to suit each flow rate, supporting a wide measurement range. - Compatible with a wide viscosity range. ・Low pressure loss. ・Fast response ・High pressure specification ・Low noise ・High precision measurement with excellent reproducibility is possible. - Stable measurements can be performed even in a wide temperature range. ・It maintains extremely high measurement accuracy even in the measurable low flow rate range. ・Highly reliable electronic equipment. - Preamplifier wiring is also easy. ・Operation is indicated by LED. - Sensors and amplifiers can be easily replaced. - Explosion-proof specifications are available for all models. ■Explosion-proof specification (ATEX) overview - Explosion-proof specifications can be selected for all flowmeter models. - Consists of a flowmeter and intrinsically safe electronic equipment (switching amplifier K-130), and is certified as intrinsically safe. ・The flowmeter body should be installed in a hazardous area, and the switching amplifier (K-130) should be installed in a safe area. ・The flow meter and switching amplifier are electrically connected and convert the signal from the sensor into a square wave. ・The flowmeter cannot be used in hazardous areas without a switching amplifier. ・The flowmeter and switching amplifier can be connected up to a maximum of 400m. ・Power supply, disconnection, short circuit, etc. can be confirmed using the LED on the switching amplifier.

  • Product

    Positive displacement gear flow meter VC series

Share this product


770+ people viewing

Last viewed: 13 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Positive displacement gear flow meter VC series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) 2-phase phase difference Ambient temperature (Seal material EPDM) Ambient temperature (Seal material FFKM) Ambient temperature (Seal material FKM) Ambient temperature (seal material FEP) Flow direction Flow range (l/min) Fluid temperature Explosion-proof type Fluid temperature High temperature type Fluid temperature standard type Fluid viscosity Maximum working pressure High pressure/79 (bar) Maximum working pressure Standard (bar) Mounting position Noise level (dB (A) ) Output Output pulse Output pulse form Peak pressure High pressure/79 (bar) Peak pressure standard (bar) Piping connections Power consumption Pressure loss Protection class Pulse vibration Resolution (lmp/l) Rotation start flow rate (l/min) Type/design Volume value per tooth (㎤) Working voltage
Positive displacement gear flow meter VC series-Part Number-VC0.025

VC0.025

Available upon quote 90°±30° -30℃~+80℃ -15℃~+80℃ -15℃~+80℃ -30℃~+80℃ Bidirectional 0.008~2 (depending on application series) -15℃~+80℃ (depending on seal material and application series) -15℃~+150℃ (depending on seal material and application series) -15℃~+120℃ (depending on seal material and application series) 1~100,000mm2/s (depending on application series) - Pmax=400 Any LA<60 PNP (NPN compatible) 2-phase signal (90° phase) Square wave, pulse duty, 1:1±15% - ^P=480 Plate connection/direct piping Pbmax=0.9W △Pmax=16bar IP65 DIN 40050 Uout≥0.8Uop 40,000.00 0.001 Gear motor Vgz=0.025 12~30VDC
Positive displacement gear flow meter VC series-Part Number-VC0.04

VC0.04

Available upon quote 90°±30° -30℃~+80℃ -15℃~+80℃ -15℃~+80℃ -30℃~+80℃ Bidirectional 0.02~4 (depending on application series) -15℃~+80℃ (depending on seal material and application series) -15℃~+150℃ (depending on seal material and application series) -15℃~+120℃ (depending on seal material and application series) 1~100,000mm2/s (depending on application series) - Pmax=400 Any LA<60 PNP (NPN compatible) 2-phase signal (90° phase) Square wave, pulse duty, 1:1±15% - ^P=480 Plate connection/direct piping Pbmax=0.9W △Pmax=16bar IP65 DIN 40050 Uout≥0.8Uop 25,000.00 0.004 Gear motor Vgz=0.04 12~30VDC
Positive displacement gear flow meter VC series-Part Number-VC0.1

VC0.1

Available upon quote 90°±30° -30℃~+80℃ -15℃~+80℃ -15℃~+80℃ -30℃~+80℃ Bidirectional 0.04~8 (depending on application series) -15℃~+80℃ (depending on seal material and application series) -15℃~+150℃ (depending on seal material and application series) -15℃~+120℃ (depending on seal material and application series) 1~100,000mm2/s (depending on application series) - Pmax=400 Any LA<60 PNP (NPN compatible) 2-phase signal (90° phase) Square wave, pulse duty, 1:1±15% - ^P=480 Plate connection/direct piping Pbmax=0.9W △Pmax=16bar IP65 DIN 40050 Uout≥0.8Uop 10,000.00 0.008 Gear motor Vgz=0.1 12~30VDC
Positive displacement gear flow meter VC series-Part Number-VC0.2

VC0.2

Available upon quote 90°±30° -30℃~+80℃ -15℃~+80℃ -15℃~+80℃ -30℃~+80℃ Bidirectional 0.16~16 (depending on application series) -15℃~+80℃ (depending on seal material and application series) -15℃~+150℃ (depending on seal material and application series) -15℃~+120℃ (depending on seal material and application series) 1~100,000mm2/s (depending on application series) - Pmax=400 Any LA<60 PNP (NPN compatible) 2-phase signal (90° phase) Square wave, pulse duty, 1:1±15% - ^P=480 Plate connection/direct piping Pbmax=0.9W △Pmax=16bar IP65 DIN 40050 Uout≥0.8Uop 4,081.63 0.01 Gear motor Vgz=0.245 12~30VDC
Positive displacement gear flow meter VC series-Part Number-VC0.4

VC0.4

Available upon quote 90°±30° -30℃~+80℃ -15℃~+80℃ -15℃~+80℃ -30℃~+80℃ Bidirectional 0.2~40 (depending on application series) -15℃~+80℃ (depending on seal material and application series) -15℃~+150℃ (depending on seal material and application series) -15℃~+120℃ (depending on seal material and application series) 1~100,000mm2/s (depending on application series) - Pmax=400 Any LA<70 PNP (NPN compatible) 2-phase signal (90° phase) Square wave, pulse duty, 1:1±15% - ^P=480 Plate connection/direct piping Pbmax=0.9W △Pmax=16bar IP65 DIN 40050 Uout≥0.8Uop 2,500.00 0.01 Gear motor Vgz=0.4 12~30VDC
Positive displacement gear flow meter VC series-Part Number-VC1

VC1

Available upon quote 90°±30° -30℃~+80℃ -15℃~+80℃ -15℃~+80℃ -30℃~+80℃ Bidirectional 0.3~80 (depending on application series) -15℃~+80℃ (depending on seal material and application series) -15℃~+150℃ (depending on seal material and application series) -15℃~+120℃ (depending on seal material and application series) 1~100,000mm2/s (depending on application series) - Pmax=400 Any LA<70 PNP (NPN compatible) 2-phase signal (90° phase) Square wave, pulse duty, 1:1±15% - ^P=480 Plate connection/direct piping Pbmax=0.9W △Pmax=16bar IP65 DIN 40050 Uout≥0.8Uop 965.25 0.02 Gear motor Vgz=1.036 12~30VDC
Positive displacement gear flow meter VC series-Part Number-VC3

VC3

Available upon quote 90°±30° -30℃~+80℃ -15℃~+80℃ -15℃~+80℃ -30℃~+80℃ Bidirectional 0.6~160 (depending on application series) -15℃~+80℃ (depending on seal material and application series) -15℃~+150℃ (depending on seal material and application series) -15℃~+120℃ (depending on seal material and application series) 1~100,000mm2/s (depending on application series) Pmax=400 Pmax=315 Any LA<70 PNP (NPN compatible) 2-phase signal (90° phase) Square wave, pulse duty, 1:1±15% ^P=480 ^P=350 Plate connection/direct piping Pbmax=0.9W △Pmax=16bar IP65 DIN 40050 Uout≥0.8Uop 333.33 0.03 Gear motor Vgz=3.000 12~30VDC
Positive displacement gear flow meter VC series-Part Number-VC5

VC5

Available upon quote 90°±30° -30℃~+80℃ -15℃~+80℃ -15℃~+80℃ -30℃~+80℃ Bidirectional 1~250 (depending on application series) -15℃~+80℃ (depending on seal material and application series) -15℃~+150℃ (depending on seal material and application series) -15℃~+120℃ (depending on seal material and application series) 1~100,000mm2/s (depending on application series) Pmax=400 Pmax=315 Any LA<72 PNP (NPN compatible) 2-phase signal (90° phase) Square wave, pulse duty, 1:1±15% ^P=480 ^P=350 Plate connection/direct piping Pbmax=0.9W △Pmax=16bar IP65 DIN 40050 Uout≥0.8Uop 191.5 0.04 Gear motor Vgz=5.222 12~30VDC
Positive displacement gear flow meter VC series-Part Number-VC12

VC12

Available upon quote 90°±30° -30℃~+80℃ -15℃~+80℃ -15℃~+80℃ -30℃~+80℃ Bidirectional 2~600 (depending on application series) -15℃~+80℃ (depending on seal material and application series) -15℃~+150℃ (depending on seal material and application series) -15℃~+120℃ (depending on seal material and application series) 1~100,000mm2/s (depending on application series) - Pmax=400 Any LA<80 PNP (NPN compatible) 2-phase signal (90° phase) Square wave, pulse duty, 1:1±15% - ^P=480 Plate connection/direct piping Pbmax=0.9W △Pmax=16bar IP65 DIN 40050 Uout≥0.8Uop 83.33 0.1 Gear motor Vgz=12.000 12~30VDC
Positive displacement gear flow meter VC series-Part Number-VC16

VC16

Available upon quote 90°±30° -30℃~+80℃ -15℃~+80℃ -15℃~+80℃ -30℃~+80℃ Bidirectional 3~700 (depending on application series) -15℃~+80℃ (depending on seal material and application series) -15℃~+150℃ (depending on seal material and application series) -15℃~+120℃ (depending on seal material and application series) 1~100,000mm2/s (depending on application series) - Pmax=400 Any LA<80 PNP (NPN compatible) 2-phase signal (90° phase) Square wave, pulse duty, 1:1±15% - ^P=480 Plate connection/direct piping Pbmax=0.9W △Pmax=16bar IP65 DIN 40050 Uout≥0.8Uop 62.5 0.2 Gear motor Vgz=16.000 12~30VDC

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Nippon Mekuman Co., Ltd.


View more products of Nippon Mekuman Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree