All Categories

History

Quick Change System Optional Electric Feed Through Module SWO-E-SWO-X7b-A
Quick Change System Optional Electric Feed Through Module SWO-E-SWO-X7C-A
Quick Change System Optional Electric Feed Through Module SWO-E-SWO-X7D-A
Quick Change System Optional Electric Feed Through Module SWO-E-SWO-E3A-K
Quick Change System Optional Electric Feed Through Module SWO-E-SWO-R32-A
Quick Change System Optional Electric Feed Through Module SWO-E-Sunk Japan Co., Ltd.

Quick Change System Optional Electric Feed Through Module SWO-E
Sunk Japan Co., Ltd.


About This Product

Electric feed -through module Various electrical signals for SCHUNK quick change systems and options for feed through current Advantages and benefits

■ Perfect fit

Simple combination with Schunk change system

■ Wide range of various variations

For various electrical and fluid media feeds through

■ Various modules

A module suitable for all sizes of the Schunk tool change system

■ Radiation portion, axis, and side cable Outlet connector / variations model

Perfect for restricted space with a low interference contour

■ Combination of multiple optional modules

Realizes the maximum flexibility of the change system

■ Minimize wear

Long useful life that can withstand many change cycles

■ Custom designs unique to customers are also available according to your request

Solutions suitable for any application

■ Cable connector, extension cable and protection cover can be used according to requests

Providing a one -stop comprehensive complete solution * There are other part numbers.

  • Product

    Quick Change System Optional Electric Feed Through Module SWO-E

Share this product


340+ people viewing

Last viewed: 1 hour ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Quick Change System Optional Electric Feed Through Module SWO-E

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Suitable use Figure of screw connection Type of transmission Weight (kg) Minimum peripheral temperature (℃) Maximum surrounding temperature (℃) Pin contact number Electrical connection Electrical connection outlet Special characteristics Rated current (A) Exchange current IP protection grade
Quick Change System Optional Electric Feed Through Module SWO-E-Part Number-SWO-X7b-A

SWO-X7b-A

Available upon quote

Tool change adapter

J

signal

0.12

5

60

1

AMPHENOL RF BNC Buchse

Diameter direction

High frequency signal up to 4 GHz, BNC protection insulated from module housing.

- - -
Quick Change System Optional Electric Feed Through Module SWO-E-Part Number-SWO-X7b-K

SWO-X7b-K

Available upon quote

Quick-Change Master

J

signal

0.16

5

60

1

AMPHENOL RF BNC Buchse

Diameter direction

High frequency signal up to 4 GHz, BNC protection insulated from module housing.

- - -
Quick Change System Optional Electric Feed Through Module SWO-E-Part Number-SWO-X7C-A

SWO-X7C-A

Available upon quote

Tool change adapter

J

signal

0.17

5

60

1

BulkHead SHV

Diameter direction

Module housing shielding protection for the ultrasound of welding and cutting applications.

3

2,000

-
Quick Change System Optional Electric Feed Through Module SWO-E-Part Number-SWO-X7C-K

SWO-X7C-K

Available upon quote

Quick-Change Master

J

signal

0.21

5

60

1

BulkHead SHV

Diameter direction

Module housing shielding protection for the ultrasound of welding and cutting applications.

3

2,000

-
Quick Change System Optional Electric Feed Through Module SWO-E-Part Number-SWO-X7D-A

SWO-X7D-A

Available upon quote

Tool change adapter

J

signal

0.13

5

60

1

AMPHENOL RF BNC Buchse

Diameter direction

Power is supplied to the feed through the high frequency signal up to 4 GHz.

5

500

-
Quick Change System Optional Electric Feed Through Module SWO-E-Part Number-SWO-E3A-K

SWO-E3A-K

Available upon quote

Quick-Change Master

S5

signal

0.022

5

60

30

Handing contact

Axial direction

-

3

50

-
Quick Change System Optional Electric Feed Through Module SWO-E-Part Number-SWO-R32-A

SWO-R32-A

Available upon quote

Tool change adapter

J

signal

0.25

5

60

32

AMPHENOL PT Bayonet Rock Socket T, 36 Pins

Diameter direction

-

3

250

IP65 (only when connecting)

Quick Change System Optional Electric Feed Through Module SWO-E-Part Number-SWO-R32-K

SWO-R32-K

Available upon quote

Quick-Change Master

J

signal

0.33

5

60

32

AMPHENOL PT Bayonet Lock Convertor, 36 Pins

Diameter direction

-

3

250

IP65 (only when connecting)

Quick Change System Optional Electric Feed Through Module SWO-E-Part Number-SWO-R32R-K

SWO-R32R-K

Available upon quote

Quick-Change Master

J

signal

0.29

5

60

32

AMPHENOL PT Bayonet Rock Socket T, 36 Pins

Diameter direction

The two integrated cables have a right angle M8 socket (A code, 3-pin), for locks and unlock sensors.

3

250

IP65 (only when connecting)

Quick Change System Optional Electric Feed Through Module SWO-E-Part Number-SWO-R32W-K

SWO-R32W-K

Available upon quote

Quick-Change Master

J

signal

0.29

5

60

32

AMPHENOL PT Bayonet Lock Convertor, 36 Pins

Diameter direction

The two integrated cables have a straight M8 socket (A code, 3-pin), for lock and unlock sensor.

3

250

IP65 (only when connecting)

Click on the part number for more information about each product

Other products of Sunk Japan Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Sunk Japan Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree