Accurately recording pressure and temperature at the specified logging interval recording temperature / pressure data logger PR1000 seriesHandling Company
Krone Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Temperature sensor | Temperature range | Temperature decomposition ability | Proofreading accuracy | pressure sensor | Pressure range | Pressure decomposition ability | Pressure response time | Repetition | Start logging | Real -time measurement | Memory number | Overwritten mode | Logging interval | Proofreading | Calibration day | Battery type | Battery life | data form | Time accuracy | PC interface | Operating system conformity | Compatible software | usage environment | size | weight | IP standard | Material | Conformity standard |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PR1000-1000A |
Available upon quote |
Semiconductor |
-40 ℃ ~+80 ℃ |
1.0 ℃ |
± 2.0 ° C: 0 ℃ ~+50 ℃ |
Semiconductor Strungage |
0-1,000 PSIA |
0.02 PSIA |
0.1 m seconds (10 to 90%FSR) |
± 0.5% fsr; ± 0.2% (normal) |
Start immediately from the software or program up to 6 months |
Connect to a PC and monitor and record data in real time |
1,396,736 |
Possible |
Free once every second to 24 hours |
Digital school from software |
Automatic record for data logger |
3.6 V lithium batteries, batteries can be replaced by everyone |
Usually one year (when logging is every 1 minute in 25 ° C environment) |
Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m |
± 1 minute/month (for 25 ° C) |
IFC400 or IFC406 Docking Station is required |
Windows 7, 8, 10 |
Standard Madgetech 4 Software 4.2.21.1 or later |
-40 ℃ ~ +80 ℃ |
Length 91.3 mm x diameter 24.6 mm |
156 |
IP68 |
316 Stainless steel/Redel resin |
CE |
|
PR1000-100A |
Available upon quote |
Semiconductor |
-40 ℃ ~+80 ℃ |
1.0 ℃ |
± 2.0 ° C: 0 ℃ ~+50 ℃ |
Semiconductor Strungage |
0-100 PSIA |
0.002 PSIA |
0.1 m seconds (10 to 90%FSR) |
± 0.5% fsr; ± 0.2% (normal) |
Start immediately from the software or program up to 6 months |
Connect to a PC and monitor and record data in real time |
1,396,736 |
Possible |
Free once every second to 24 hours |
Digital school from software |
Automatic record for data logger |
3.6 V lithium batteries, batteries can be replaced by everyone |
Usually one year (when logging is every 1 minute in 25 ° C environment) |
Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m |
± 1 minute/month (for 25 ° C) |
IFC400 or IFC406 Docking Station is required |
Windows 7, 8, 10 |
Standard Madgetech 4 Software 4.2.21.1 or later |
-40 ℃ ~ +80 ℃ |
Length 91.3 mm x diameter 24.6 mm |
156 |
IP68 |
316 Stainless steel/Redel resin |
CE |
|
PR1000-100G |
Available upon quote |
Semiconductor |
-40 ℃ ~+80 ℃ |
1.0 ℃ |
± 2.0 ° C: 0 ℃ ~+50 ℃ |
Semiconductor Strungage |
0-100 PSIG |
0.002 PSIG |
0.1 m seconds (10 to 90%FSR) |
± 0.5% fsr; ± 0.2% (normal) |
Start immediately from the software or program up to 6 months |
Connect to a PC and monitor and record data in real time |
1,396,736 |
Possible |
Free once every second to 24 hours |
Digital school from software |
Automatic record for data logger |
3.6 V lithium batteries, batteries can be replaced by everyone |
Usually one year (when logging is every 1 minute in 25 ° C environment) |
Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m |
± 1 minute/month (for 25 ° C) |
IFC400 or IFC406 Docking Station is required |
Windows 7, 8, 10 |
Standard Madgetech 4 Software 4.2.21.1 or later |
-40 ℃ ~ +80 ℃ |
Length 91.3 mm x diameter 24.6 mm |
156 |
IP68 |
316 Stainless steel/Redel resin |
CE |
|
PR1000-300A |
Available upon quote |
Semiconductor |
-40 ℃ ~+80 ℃ |
1.0 ℃ |
± 2.0 ° C: 0 ℃ ~+50 ℃ |
Semiconductor Strungage |
0-300 PSIA |
0.005 PSIA |
0.1 m seconds (10 to 90%FSR) |
± 0.5% fsr; ± 0.2% (normal) |
Start immediately from the software or program up to 6 months |
Connect to a PC and monitor and record data in real time |
1,396,736 |
Possible |
Free once every second to 24 hours |
Digital school from software |
Automatic record for data logger |
3.6 V lithium batteries, batteries can be replaced by everyone |
Usually one year (when logging is every 1 minute in 25 ° C environment) |
Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m |
± 1 minute/month (for 25 ° C) |
IFC400 or IFC406 Docking Station is required |
Windows 7, 8, 10 |
Standard Madgetech 4 Software 4.2.21.1 or later |
-40 ℃ ~ +80 ℃ |
Length 91.3 mm x diameter 24.6 mm |
156 |
IP68 |
316 Stainless steel/Redel resin |
CE |
|
PR1000-300G |
Available upon quote |
Semiconductor |
-40 ℃ ~+80 ℃ |
1.0 ℃ |
± 2.0 ° C: 0 ℃ ~+50 ℃ |
Semiconductor Strungage |
0-300 PSIG |
0.005 PSIG |
0.1 m seconds (10 to 90%FSR) |
± 0.5% fsr; ± 0.2% (normal) |
Start immediately from the software or program up to 6 months |
Connect to a PC and monitor and record data in real time |
1,396,736 |
Possible |
Free once every second to 24 hours |
Digital school from software |
Automatic record for data logger |
3.6 V lithium batteries, batteries can be replaced by everyone |
Usually one year (when logging is every 1 minute in 25 ° C environment) |
Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m |
± 1 minute/month (for 25 ° C) |
IFC400 or IFC406 Docking Station is required |
Windows 7, 8, 10 |
Standard Madgetech 4 Software 4.2.21.1 or later |
-40 ℃ ~ +80 ℃ |
Length 91.3 mm x diameter 24.6 mm |
156 |
IP68 |
316 Stainless steel/Redel resin |
CE |
|
PR1000-30A |
Available upon quote |
Semiconductor |
-40 ℃ ~+80 ℃ |
1.0 ℃ |
± 2.0 ° C: 0 ℃ ~+50 ℃ |
Semiconductor Strungage |
0-30 PSIA |
0.0005 PSIA |
0.1 m seconds (10 to 90%FSR) |
± 0.5% fsr; ± 0.2% (normal) |
Start immediately from the software or program up to 6 months |
Connect to a PC and monitor and record data in real time |
1,396,736 |
Possible |
Free once every second to 24 hours |
Digital school from software |
Automatic record for data logger |
3.6 V lithium batteries, batteries can be replaced by everyone |
Usually one year (when logging is every 1 minute in 25 ° C environment) |
Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m |
± 1 minute/month (for 25 ° C) |
IFC400 or IFC406 Docking Station is required |
Windows 7, 8, 10 |
Standard Madgetech 4 Software 4.2.21.1 or later |
-40 ℃ ~ +80 ℃ |
Length 91.3 mm x diameter 24.6 mm |
156 |
IP68 |
316 Stainless steel/Redel resin |
CE |
|
PR1000-30G |
Available upon quote |
Semiconductor |
-40 ℃ ~+80 ℃ |
1.0 ℃ |
± 2.0 ° C: 0 ℃ ~+50 ℃ |
Semiconductor Strungage |
0-30 PSIG |
0.0005 PSIG |
0.1 m seconds (10 to 90%FSR) |
± 0.5% fsr; ± 0.2% (normal) |
Start immediately from the software or program up to 6 months |
Connect to a PC and monitor and record data in real time |
1,396,736 |
Possible |
Free once every second to 24 hours |
Digital school from software |
Automatic record for data logger |
3.6 V lithium batteries, batteries can be replaced by everyone |
Usually one year (when logging is every 1 minute in 25 ° C environment) |
Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m |
± 1 minute/month (for 25 ° C) |
IFC400 or IFC406 Docking Station is required |
Windows 7, 8, 10 |
Standard Madgetech 4 Software 4.2.21.1 or later |
-40 ℃ ~ +80 ℃ |
Length 91.3 mm x diameter 24.6 mm |
156 |
IP68 |
316 Stainless steel/Redel resin |
CE |
|
PR1000-5000A |
Available upon quote |
Semiconductor |
-40 ℃ ~+80 ℃ |
1.0 ℃ |
± 2.0 ° C: 0 ℃ ~+50 ℃ |
Semiconductor Strungage |
0-5,000 PSIA |
0.1 PSIA |
0.1 m seconds (10 to 90%FSR) |
± 0.5% fsr; ± 0.2% (normal) |
Start immediately from the software or program up to 6 months |
Connect to a PC and monitor and record data in real time |
1,396,736 |
Possible |
Free once every second to 24 hours |
Digital school from software |
Automatic record for data logger |
3.6 V lithium batteries, batteries can be replaced by everyone |
Usually one year (when logging is every 1 minute in 25 ° C environment) |
Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m |
± 1 minute/month (for 25 ° C) |
IFC400 or IFC406 Docking Station is required |
Windows 7, 8, 10 |
Standard Madgetech 4 Software 4.2.21.1 or later |
-40 ℃ ~ +80 ℃ |
Length 91.3 mm x diameter 24.6 mm |
156 |
IP68 |
316 Stainless steel/Redel resin |
CE |
|
PR1000-500A |
Available upon quote |
Semiconductor |
-40 ℃ ~+80 ℃ |
1.0 ℃ |
± 2.0 ° C: 0 ℃ ~+50 ℃ |
Semiconductor Strungage |
0-500 PSIA |
0.01 PSIA |
0.1 m seconds (10 to 90%FSR) |
± 0.5% fsr; ± 0.2% (normal) |
Start immediately from the software or program up to 6 months |
Connect to a PC and monitor and record data in real time |
1,396,736 |
Possible |
Free once every second to 24 hours |
Digital school from software |
Automatic record for data logger |
3.6 V lithium batteries, batteries can be replaced by everyone |
Usually one year (when logging is every 1 minute in 25 ° C environment) |
Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m |
± 1 minute/month (for 25 ° C) |
IFC400 or IFC406 Docking Station is required |
Windows 7, 8, 10 |
Standard Madgetech 4 Software 4.2.21.1 or later |
-40 ℃ ~ +80 ℃ |
Length 91.3 mm x diameter 24.6 mm |
156 |
IP68 |
316 Stainless steel/Redel resin |
CE |
|
PR1000-500G |
Available upon quote |
Semiconductor |
-40 ℃ ~+80 ℃ |
1.0 ℃ |
± 2.0 ° C: 0 ℃ ~+50 ℃ |
Semiconductor Strungage |
0-500 PSIG |
0.01 PSIG |
0.1 m seconds (10 to 90%FSR) |
± 0.5% fsr; ± 0.2% (normal) |
Start immediately from the software or program up to 6 months |
Connect to a PC and monitor and record data in real time |
1,396,736 |
Possible |
Free once every second to 24 hours |
Digital school from software |
Automatic record for data logger |
3.6 V lithium batteries, batteries can be replaced by everyone |
Usually one year (when logging is every 1 minute in 25 ° C environment) |
Date and time and time and time, ° f, k, ° r; mbar, psi, inhg, mmhg, atm, torr, pa, kpa, mpa, m |
± 1 minute/month (for 25 ° C) |
IFC400 or IFC406 Docking Station is required |
Windows 7, 8, 10 |
Standard Madgetech 4 Software 4.2.21.1 or later |
-40 ℃ ~ +80 ℃ |
Length 91.3 mm x diameter 24.6 mm |
156 |
IP68 |
316 Stainless steel/Redel resin |
CE |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
9.0hrs
Company Review