Wet painting booth that does not use water pump VBP-F series-VBP-15F-M5
Wet painting booth that does not use water pump VBP-F series-ANEST IWATA Corporation

Wet painting booth that does not use water pump VBP-F series
ANEST IWATA Corporation


About This Product

■ Features ・ Venture booth (wet local exhaust device). ・ A wet painting booth that does not use a water pump is sucked up with the power of the exhaust fan and produces a water film in the swirl room on the back. ・ Painting mist is drawn into it to efficiently repair the paint mist. ・ * The repaired paint mist (sludge) and water return to the front side of the underwater duct, so it is collected during maintenance. ・ Outdoor scattering of paint mist is suppressed and the conditions for the installation environment are strict, and excellent collection efficiency is exhibited. ・ The aquarium of the standard venture booth has been removed, a pit type, and the water is possible from the floor. * Please use the pit construction by the customer. ■ Other accessories ・ Sludge killer (SK-510 /520 1 box) ・ Swingrack (sludge killer dedicated pouring table) ・ 2 measuring cups ・ PH test paper 1 volume * There are other model numbers.

  • Product

    Wet painting booth that does not use water pump VBP-F series

Share this product


680+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Wet painting booth that does not use water pump VBP-F series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) All height Ceiling height H Collected efficiency Futalic acid -based acrylic paint Collected efficiency acrylic urethane paint Collected efficiency lacquer Priem paint Collected efficiency melamine paint Depth D Exhaust fan air volume Exhaust fan average wind speed Exhaust fan count Exhaust fan motor format/specifications Exhaust fan output Exhaust fan type Fan center height dimensions Frontage w Mass (kg) Noise (device side) Noise (whole device) Phase flange dimensions Primary power supply (three -phase 200V) breaker capacity (a) Standard pit specification pit depth Standard pit type specification pit depth Standard weight (L) Total mass * Including water (kg)
Wet painting booth that does not use water pump VBP-F series-Part Number-VBP-15F-M5

VBP-15F-M5

Available upon quote 2,912 2,000 95 93 96 97 2,000 110 0.6 #3 1/2 Full closed fan -shaped 200V 4P IE3 3.7 Turbo fan (directly connected motor) 2,358 1,500 567 77 80 570 x 385 60 1,400 450 630 1,197
Wet painting booth that does not use water pump VBP-F series-Part Number-VBP-20F-M5

VBP-20F-M5

Available upon quote 2,965 2,000 95 93 96 97 2,000 145 0.6 #Four Full closed fan -shaped 200V 4P IE3 3.7 Turbo fan (directly connected motor) 2,385 2,000 765 74 80 650 x 440 60 1,400 450 840 1,605
Wet painting booth that does not use water pump VBP-F series-Part Number-VBP-25F-M5

VBP-25F-M5

Available upon quote 3,008 2,000 95 93 96 97 2,000 180 0.6 #Four Full closed fan -shaped 200V 4P IE3 5.5 Turbo fan (directly connected motor) 2,385 2,500 860 76 81 650 x 440 100 1,400 450 1,050 1,910
Wet painting booth that does not use water pump VBP-F series-Part Number-VBP-30F-M5

VBP-30F-M5

Available upon quote 3,008 2,000 95 93 96 97 2,000 215 0.6 #Four Full closed fan -shaped 200V 4P IE3 5.5 Turbo fan (directly connected motor) 2,385 3,000 860 78 82 650 x 440 100 1,400 450 1,260 2,120
Wet painting booth that does not use water pump VBP-F series-Part Number-VBP-35F-M5

VBP-35F-M5

Available upon quote 3,100 2,000 95 93 96 97 2,000 250 0.6 #4 1/2 Full closed fan -shaped 200V 4P IE3 7.5 Turbo fan (directly connected motor) 2,413 3,500 1,030 79 83 730 x 495 125 1,400 450 1,470 2,500
Wet painting booth that does not use water pump VBP-F series-Part Number-VBP-40F-M5

VBP-40F-M5

Available upon quote 3,136 2,000 95 93 96 97 2,000 290 0.6 #4 1/2 Full closed fan -shaped 200V 4P IE3 11 Turbo fan (directly connected motor) 2,413 4,000 1,148 82 84 730 x 495 125 1,400 450 1,680 2,828
Wet painting booth that does not use water pump VBP-F series-Part Number-VBP-50F-M5

VBP-50F-M5

Available upon quote 3,200 2,000 95 93 96 97 2,000 360 0.6 #Five Full closed fan -shaped 200V 4P IE3 11 Turbo fan (directly connected motor) 2,450 5,000 1,273 83 85 815 x 550 125 1,400 450 2,100 3,373
Wet painting booth that does not use water pump VBP-F series-Part Number-VBP-15F-M6

VBP-15F-M6

Available upon quote 2,912 2,000 95 93 96 97 2,000 110 0.6 #3 1/2 Full closed fan -shaped 200V 4P IE3 3.7 Turbo fan (directly connected motor) 2,358 1,500 560 77 80 570 x 385 60 1,400 450 630 1,190
Wet painting booth that does not use water pump VBP-F series-Part Number-VBP-20F-M6

VBP-20F-M6

Available upon quote 2,912 2,000 95 93 96 97 2,000 145 0.6 #3 1/2 Full closed fan -shaped 200V 4P IE3 5.5 Turbo fan (directly connected motor) 2,358 2,000 715 74 80 570 x 385 60 1,400 450 840 1,555
Wet painting booth that does not use water pump VBP-F series-Part Number-VBP-25F-M6

VBP-25F-M6

Available upon quote 2,952 2,000 95 93 96 97 2,000 180 0.6 #3 1/2 Full closed fan -shaped 200V 4P IE3 5.5 Turbo fan (directly connected motor) 2,358 2,500 810 76 81 570 x 385 100 1,400 450 1,050 1,860

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of ANEST IWATA Corporation


View more products of ANEST IWATA Corporation

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree