Plug-in-type digital instruction dissolved oxygen WIL-102-DOHandling Company
Shinko Technos Co., Ltd.Categories
Usage Scenarios
Environment & Recycling Use / Pharmaceutical & Medical Use / Chemical Industry UseClick on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Measurement range (rated scale) Dolut oxygen concentration | Measurement range (rated scale) Dolut oxygen saturation rate | Measurement range (rated scale) oxygen partial pressure | Measurement range (rated scale) temperature | Instruction accuracy | Time accuracy | Data update cycle | Serial communication | Serial communication cable length | Serial communication communication line | Serial communication communication method | Serial communication communication speed | Serial communication synchronous method | Serial communication format | Serial communication and communication protocol | Serial communication data bit/Parity | Serial communication stop bit | Serial communication error correction | Serial communication error detection | Transmission output 1, 2-1 | Transmission output 1, 2-2 | Transmission output 1, 2-3 | Self -diagnostic function | input | Ambient temperature | Peripheral humidity | power supply | structure | Protective structure | Conformity standard |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
WIL-102-DO, EVT |
Available upon quote |
Scenery: 0.00 ~ 20.00 mg/L, resolution ability: 0.01 mg/l |
Scenery range: 0.0-200.0 %, decomposition ability: 0.1 % |
Scenery: 0.0 ~ 150.0 kpa, resolution ability: 0.1 kpa |
Scale range: 0.0 to 50.0 ° C, decomposition ability: 0.1 ℃ |
Rely on the accuracy of the fluorescent dissolved oxygen detector |
Within ± 1%for the set time |
5 seconds |
Perform the following operations from the external computer.・ Read and configure values and set -dissolved oxygen concentration, dissolved oxygen saturation rate, oxygen arbitration, temperature reading / function change, adjustment / user storage area reading and setting. |
1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) |
EIA RS-485 compliant |
Half double communication |
Select 9600, 19200, 38400 BPS by key operation |
Toning synchronization |
ASCII, binary |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation |
8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation |
Select 1 bit and 2 bits by key operation |
Command resend |
・ Parity check, checksum (Shinko standard) |
Converts the dissolved oxygen concentration, water temperature, dissolved oxygen saturation rate, oxygen pressure or MV for each data update cycle, and output it in current. |
If the transmission output maximum value and the lower limit of the transmission output are set to the same value, the transmission output is fixed to 4 ma DC. |
・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: Transmit output 1 span or transmission output within ± 0.3%of span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Fluorescent molten oxygen detector |
0 to 50 ℃ |
35 ~ 85%RH (but not condensation) |
100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
・ DIN rail mounting method ・ Case: flame -retardant resin color: Light gray panel: Membrane sheet |
Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
ROHS command support |
|
WIL-102-DO1, EVT |
Available upon quote |
Scenery: 0.00 ~ 20.00 mg/L, resolution ability: 0.01 mg/l |
Scenery range: 0.0-200.0 %, decomposition ability: 0.1 % |
Scenery: 0.0 ~ 150.0 kpa, resolution ability: 0.1 kpa |
Scale range: 0.0 to 50.0 ° C, decomposition ability: 0.1 ℃ |
Rely on the accuracy of the fluorescent dissolved oxygen detector |
Within ± 1%for the set time |
5 seconds |
Perform the following operations from the external computer. |
1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) |
EIA RS-485 compliant |
Half double communication |
Select 9600, 19200, 38400 BPS by key operation |
Toning synchronization |
ASCII, binary |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation |
8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation |
Select 1 bit and 2 bits by key operation |
Command resend |
・ Parity check, checksum (Shinko standard) |
Converts the dissolved oxygen concentration, water temperature, dissolved oxygen saturation rate, oxygen pressure or MV for each data update cycle, and output it in current. |
If the transmission output maximum value and the lower limit of the transmission output are set to the same value, the transmission output is fixed to 4 ma DC. |
・ Dusive ability: 12000 ・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: Transmit output 1 span or transmission output within ± 0.3%of span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
Fluorescent molten oxygen detector |
0 to 50 ℃ |
35 ~ 85%RH (but not condensation) |
24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC |
・ DIN rail mounting method |
Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
ROHS command support |
Click on the part number for more information about each product