Digital instruction turbidity/SS meter Aer-101-TU-Aer-101-Tu, C5
Digital instruction turbidity/SS meter Aer-101-TU-Shinko Technos Co., Ltd.

Digital instruction turbidity/SS meter Aer-101-TU
Shinko Technos Co., Ltd.

♻️ Environment & Recycling Use 💊 Pharmaceutical & Medical Use 🧪 Chemical Industry Use

About This Product

Digital instruction turbidity/SS meter that is installed on the control board panel surface that supports various purposes such as top water, drainage, training equipment, and building equipment. ・ 48 × 96mm square, panel mount type ・ Drip -proof / dustproof structure IP66 compatible (front panel) ・ Compatible with power supply voltage 24 v AC/DC (specified by form name) ・ Various settings and calibration operations are possible via communication (RS-485) (optional)

  • Product

    Digital instruction turbidity/SS meter Aer-101-TU
  • Usage Scenarios

    Environment & Recycling Use / Pharmaceutical & Medical Use / Chemical Industry Use

Share this product


240+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

2 Models of Digital instruction turbidity/SS meter Aer-101-TU

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Ambient temperature Conformity standard Contact output External dimensions Input sampling cycle Linearness Moving average number Peripheral humidity Protective structure Repetition Self -diagnostic function Serial Communication (Options: C5) Data Bit/Parity Serial communication (Options: C5) Serial communication (Options: C5) Certification format Serial communication (Options: C5) Communication method Serial communication (Options: C5) Communication protocol Serial communication (Options: C5) Communication speed Serial communication (Options: C5) Stop bit Serial communication (Options: C5) Sync Serial communication (Options: C5) error correction Serial communication (option: C5) cable length Serial communication (option: C5) communication line Serial communication (option: C5) error detection Time accuracy Transmission output 1 Transmission output 2 mass power supply structure
Digital instruction turbidity/SS meter Aer-101-TU-Part Number-Aer-101-Tu, C5

Aer-101-Tu, C5

Available upon quote 0 to 50 ℃ ROHS command support ・ Relay contact 1A
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
・ Control operation: P operation, ON/OFF operation
W48XH96XD110mm case depth: 98.5mm (at panel mount) 500ms ± 0.2%± 1 digit of the measurement range span (however, no sensor accuracy is included) 1 to 120 times 35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) ± 0.2%± 1 digit of the measurement range span (however, no sensor accuracy is included) Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation Perform the following operations from the external computer.
・ Read and set various set values
・ Calculation/SS input value, state reading
・ Change and adjust function
・ Reading and setting of user storage area
ASCII, binary Half double communication Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation Select 9,600, 19,200, 38,400 BPS by key operation Select 1 bit and 2 bits by key operation Toning synchronization Command resend 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant ・ Parity check, checksum (Shinko standard)
・ LRC (Modbus ASCII), CRC-16 (Modbus RTU)
Within ± 1%for the set time ・ Convert the turbidity/SS input value and MV to the analog amount for each input sampling, and output it by current.
・ If the transmission output maximum value and the transmission output lower limit are set to the same value, the transmission output is fixed to 4 ma DC.
・ The transmission output volume can be displayed.
・ Resolution: 12,000
・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω)
・ Output accuracy: within ± 0.3%of transmission output 1 span
Approximately 280g 100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC ・ Control board embedded method (compatible panel thickness 1 ~ 8mm)
・ Case: flame -retardant resin color: black
・ Panel: Membrane sheet
・ Drip -proof / dustproof structure: front IP66
Digital instruction turbidity/SS meter Aer-101-TU-Part Number-AER-101-TU1, C5

AER-101-TU1, C5

Available upon quote 0 to 50 ℃ ROHS command support ・ Relay contact 1A
・ Control capacity: 3A 250V AC (resistance load), 1A 250V AC (induced load COSφ = 0.4)
・ Electrical life: 100,000 times
・ Control operation: P operation, ON/OFF operation
W48XH96XD110mm case depth: 98.5mm (at panel mount) 500ms ± 0.2%± 1 digit of the measurement range span (however, no sensor accuracy is included) 1 to 120 times 35 ~ 85%RH (but not condensation) Over-pressure category Ⅱ, pollution 2 (IEC61010-1) ± 0.2%± 1 digit of the measurement range span (however, no sensor accuracy is included) Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. 8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation Perform the following operations from the external computer.
・ Read and set various set values
・ Calculation/SS input value, state reading
・ Change and adjust function
・ Reading and setting of user storage area
ASCII, binary Half double communication Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation Select 9,600, 19,200, 38,400 BPS by key operation Select 1 bit and 2 bits by key operation Toning synchronization Command resend 1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) EIA RS-485 compliant ・ Parity check, checksum (Shinko standard)
・ LRC (Modbus ASCII), CRC-16 (Modbus RTU)
Within ± 1%for the set time ・ Convert the turbidity/SS input value and MV to the analog amount for each input sampling, and output it by current.
・ If the transmission output maximum value and the transmission output lower limit are set to the same value, the transmission output is fixed to 4 ma DC.
・ The transmission output volume can be displayed.
・ Resolution: 12,000
・ Current: 4 ~ 20mA DC (maximum load resistance 550Ω)
・ Output accuracy: within ± 0.3%of transmission output 1 span
Approximately 280g 24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC ・ Control board embedded method (compatible panel thickness 1 ~ 8mm)
・ Case: flame -retardant resin color: black
・ Panel: Membrane sheet
・ Drip -proof / dustproof structure: front IP66

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Shinko Technos Co., Ltd.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree