All Categories
History
Response Rate
100.0%
Response Time
53.0hours
Product
Digital instruction pH meter Aer-102-pHHandling Company
Shinko Technos Co., Ltd.Categories
Usage Scenarios
Chemical Industry Use / Environment & Recycling Use / Pharmaceutical & Medical UseClick on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Measurement range (rated scale) | Repetition | Linearness | Instruction accuracy | Calibration function 1 | Calibric function 2 | Contact output | Transmission output 1-1 | Transmission output 1-2 | Transmission output 1-3 | Self -diagnostic function | Temperature compensation range | Ambient temperature | Peripheral humidity | power supply | structure | Protective structure | Conformity standard | External dimensions | mass | Serial communication (Options: C5) | Serial communication (option: C5) cable length | Serial communication (option: C5) communication line | Serial communication (Options: C5) Communication method | Serial communication (Options: C5) Communication speed | Serial communication (Options: C5) Sync | Serial communication (Options: C5) Certification format | Serial communication (Options: C5) Communication protocol | Serial Communication (Options: C5) Data Bit/Parity | Serial communication (Options: C5) Stop bit |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AER-102-PH, C5 |
Available upon quote |
・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH |
PH value: ± 0.05 pH |
PH value: ± 0.05 pH |
Temperature: ± 1 ℃ |
2 Automatic proofreading or manual proofreading |
Temperature school regular (1 point) |
・ Relay contact 1A |
・ PH, temperature, and MV are converted to analog amount for each input sampling, and output by current (when shipment of factory: pH) |
・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is fixed to 4 ma DC. |
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
0.0 to 100.0 ° C |
0 to 50 ℃ |
35 ~ 85%RH (but not condensation) |
100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
・ Control board embedded method (compatible panel thickness 1 ~ 8mm) |
Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
ROHS command support |
W48XH96XD110mm case depth: 98.5mm (at panel mount) |
Approximately 280g |
Perform the following operations from the external computer. |
1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) |
EIA RS-485 compliant |
Half double communication |
Select 9600, 19200, 38400 BPS by key operation |
Toning synchronization |
ASCII, binary |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation |
8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation |
Select 1 bit and 2 bits by key operation |
|
AER-102-PH, EVT3 |
Available upon quote |
・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH |
PH value: ± 0.05 pH |
PH value: ± 0.05 pH |
Temperature: ± 1 ℃ |
2 Automatic proofreading or manual proofreading |
Temperature school regular (1 point) |
・ Relay contact 1A |
・ PH, temperature, and MV are converted to analog amount for each input sampling, and output by current (when shipment of factory: pH) |
・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is fixed to 4 ma DC. |
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
0.0 to 100.0 ° C |
0 to 50 ℃ |
35 ~ 85%RH (but not condensation) |
100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
・ Control board embedded method (compatible panel thickness 1 ~ 8mm) |
Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
ROHS command support |
W48XH96XD110mm case depth: 98.5mm (at panel mount) |
Approximately 280g |
Perform the following operations from the external computer. |
- | - | - | - | - | - | - | - | - | |
Aer-102-PH, TA2 |
Available upon quote |
・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH |
PH value: ± 0.05 pH |
PH value: ± 0.05 pH |
Temperature: ± 1 ℃ |
2 Automatic proofreading or manual proofreading |
Temperature school regular (1 point) |
・ Relay contact 1A |
・ PH, temperature, and MV are converted to analog amount for each input sampling, and output by current (when shipment of factory: pH) |
・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is fixed to 4 ma DC. |
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
0.0 to 100.0 ° C |
0 to 50 ℃ |
35 ~ 85%RH (but not condensation) |
100 ~ 240 V AC 50/60 Hz tolerance fluctuation range: 85 ~ 264 v AC |
・ Control board embedded method (compatible panel thickness 1 ~ 8mm) |
Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
ROHS command support |
W48XH96XD110mm case depth: 98.5mm (at panel mount) |
Approximately 280g |
Perform the following operations from the external computer. |
- | - | - | - | - | - | - | - | - | |
AER-102-PH1, C5 |
Available upon quote |
・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH |
PH value: ± 0.05 pH |
PH value: ± 0.05 pH |
Temperature: ± 1 ℃ |
2 Automatic proofreading or manual proofreading |
Temperature school regular (1 point) |
・ Relay contact 1A |
・ PH, temperature, and MV are converted to analog amount for each input sampling, and output by current (when shipment of factory: pH) |
・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is fixed to 4 ma DC. |
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
0.0 to 100.0 ° C |
0 to 50 ℃ |
35 ~ 85%RH (but not condensation) |
24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC |
・ Control board embedded method (compatible panel thickness 1 ~ 8mm) |
Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
ROHS command support |
W48XH96XD110mm case depth: 98.5mm (at panel mount) |
Approximately 280g |
Perform the following operations from the external computer. |
1.2 km (maximum) Cable resistance within 50Ω (end resistance: None or 120Ω or more on both sides) |
EIA RS-485 compliant |
Half double communication |
Select 9600, 19200, 38400 BPS by key operation |
Toning synchronization |
ASCII, binary |
Select Shinko Standard, Modbus ASCII, Modbus RTU by key operation |
8 bits/none, 7 -bit/none, 8 -bit/even number, 7 -bit/even number, 8 -bit/odd, 7 -bit/odd number by key operation |
Select 1 bit and 2 bits by key operation |
|
AER-102-PH1, EVT3 |
Available upon quote |
・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH |
PH value: ± 0.05 pH |
PH value: ± 0.05 pH |
Temperature: ± 1 ℃ |
2 Automatic proofreading or manual proofreading |
Temperature school regular (1 point) |
・ Relay contact 1A |
・ PH, temperature, and MV are converted to analog amount for each input sampling, and output by current (when shipment of factory: pH) |
・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is fixed to 4 ma DC. |
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
0.0 to 100.0 ° C |
0 to 50 ℃ |
35 ~ 85%RH (but not condensation) |
24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC |
・ Control board embedded method (compatible panel thickness 1 ~ 8mm) |
Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
ROHS command support |
W48XH96XD110mm case depth: 98.5mm (at panel mount) |
Approximately 280g |
Perform the following operations from the external computer. |
- | - | - | - | - | - | - | - | - | |
AER-102-PH1, TA2 |
Available upon quote |
・ PH value: 0.00 ~ 14.00 pH, decomposition ability: 0.01 pH |
PH value: ± 0.05 pH |
PH value: ± 0.05 pH |
Temperature: ± 1 ℃ |
2 Automatic proofreading or manual proofreading |
Temperature school regular (1 point) |
・ Relay contact 1A |
・ PH, temperature, and MV are converted to analog amount for each input sampling, and output by current (when shipment of factory: pH) |
・ If the transmission output 1 maximum value and transmission output 1 are set to the same value, the transmission output 1 is fixed to 4 ma DC. |
・ Dusive ability: 12000 ・ Current: 4 to 20mA DC (maximum load resistance 550Ω) ・ Output accuracy: within ± 0.3%of transmission output 1 span |
Motor the CPU with a watchdog timer and make the instrument into an initial state in the event of an abnormality. |
0.0 to 100.0 ° C |
0 to 50 ℃ |
35 ~ 85%RH (but not condensation) |
24 V AC/DC 50/60 Hz Available range range: 20-28 v AC/DC |
・ Control board embedded method (compatible panel thickness 1 ~ 8mm) |
Over-pressure category Ⅱ, pollution 2 (IEC61010-1) |
ROHS command support |
W48XH96XD110mm case depth: 98.5mm (at panel mount) |
Approximately 280g |
Perform the following operations from the external computer. |
- | - | - | - | - | - | - | - | - |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
53.0hrs