All Categories

History

DIN rail mounting type digital instruction adjustment meter DCL-33A-DCL-33A-R/M
DIN rail mounting type digital instruction adjustment meter DCL-33A-DCL-33A-R/M 1
DIN rail mounting type digital instruction adjustment meter DCL-33A-DCL-33A-S/M
DIN rail mounting type digital instruction adjustment meter DCL-33A-DCL-33A-S/M 1
DIN rail mounting type digital instruction adjustment meter DCL-33A-DCL-33A-A/M
DIN rail mounting type digital instruction adjustment meter DCL-33A-DCL-33A-A/M 1
DIN rail mounting type digital instruction adjustment meter DCL-33A-DCL-33A-R/M, W (5A)
DIN rail mounting type digital instruction adjustment meter DCL-33A-Shinko Technos Co., Ltd.

DIN rail mounting type digital instruction adjustment meter DCL-33A
Shinko Technos Co., Ltd.

🍎 Food Industry Use ⚙️ Plastic & Rubber Manufacturing 🔩 Metal Processing Industry Use

Shinko Technos Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

53.0hours


About This Product

It is an instruction tube with easy mounting on the DIN rail in the board with excellent cost performance. It is possible to expand according to the measurement control point. Although it is compact, the communication function, the heater disconnection function, and the heating and cooling can be selected as optional. ・ 4 digits LED display ・ Reduction of man -hours by stick terminal connection ・ Equipped with a simple conversion device function

■ Just fit in the control board

Compact with a width of 22.5mm, 75mm high, 100mm in depth. Din rails are also installed inside the device.

■ Multi input, high -speed sampling

It supports a total of 18 types: thermoelectric vs (10 types), measuring temperature resistor (2 types), DC current (2 types), and DC voltage (4 types). 125ms high -speed sampling can support a wide range of processes.

■ Enriched communication function

The communication protocol uses the world standard Modbus protocol (Modbus ASCII, Modbus RTU) as our standard and field network. We also offer monitor software. * There are other model numbers

  • Product

    DIN rail mounting type digital instruction adjustment meter DCL-33A
  • Usage Scenarios

    Food Industry Use / Plastic & Rubber Manufacturing / Metal Processing Industry Use

Share this product


450+ people viewing

Last viewed: 5 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

8 Models of DIN rail mounting type digital instruction adjustment meter DCL-33A

Click on the part number for more information about each product

Image Part Number Price (excluding tax) input Accurate thermoelectric vs. 1 Accuracy measurement temperature resistor Accurate DC current, voltage Sampling cycle Control action Control output Power-supply voltage option Event output Accurate thermoelectric vs. 2 Accurate thermoelectric vs. 3
DIN rail mounting type digital instruction adjustment meter DCL-33A-Part Number-DCL-33A-R/M

DCL-33A-R/M

Available upon quote

・ Thermal electricity vs.: K, J, S, S, B, T, N, PL-II, C (W/Re5-26) ・ Temperature resistance body: PT100, JPT100 ・ DC current: 0 ~ 20mA DC, 4 ~ 20mA DC / DC voltage: 0 ~ 1V DC, 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC

Within ± 0.2 %± 1 digit or within ± 2 ° C (4 ° F) of each input span

Within ± 0.1 %± 1 digit or within ± 1 ° C (2 ° F) of each input span

Within ± 0.2 %± 1 digit of each input span

125ms

Auto tuning PID, PI, PD, P, ON/OFF

Relay contact

100 ~ 240V AC 50/60Hz

-

Warning output, loop anomalous alarm output

・ However, 0 to 200 ° C (32-392 ° F) of R and S input within ± 6 ° C (12 ° F) ・ B 0 to 300 ° C (32 to 572 ° F) outside the precision guarantee range.

・ K, J, E, T, N's input is less than 0 ° C (32 ° F), within ± 0.4 % ± 1 digit or ± 4 ° C (8 ° F) of the input span or ± 4 ° C (8 ° F).

DIN rail mounting type digital instruction adjustment meter DCL-33A-Part Number-DCL-33A-R/M 1

DCL-33A-R/M 1

Available upon quote

・ Thermal electricity vs.: K, J, S, S, B, T, N, PL-II, C (W/Re5-26) ・ Temperature resistance body: PT100, JPT100 ・ DC current: 0 ~ 20mA DC, 4 ~ 20mA DC / DC voltage: 0 ~ 1V DC, 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC

Within ± 0.2 %± 1 digit or within ± 2 ° C (4 ° F) of each input span

Within ± 0.1 %± 1 digit or within ± 1 ° C (2 ° F) of each input span

Within ± 0.2 %± 1 digit of each input span

125ms

Auto tuning PID, PI, PD, P, ON/OFF

Relay contact

24V AC/DC 50/60Hz

-

Warning output, loop anomalous alarm output

・ However, 0 to 200 ° C (32-392 ° F) of R and S input within ± 6 ° C (12 ° F) ・ B 0 to 300 ° C (32 to 572 ° F) outside the precision guarantee range.

・ K, J, E, T, N's input is less than 0 ° C (32 ° F), within ± 0.4 % ± 1 digit or ± 4 ° C (8 ° F) of the input span or ± 4 ° C (8 ° F).

DIN rail mounting type digital instruction adjustment meter DCL-33A-Part Number-DCL-33A-S/M

DCL-33A-S/M

Available upon quote

・ Thermal electricity vs.: K, J, S, S, B, T, N, PL-II, C (W/Re5-26) ・ Temperature resistance body: PT100, JPT100 ・ DC current: 0 ~ 20mA DC, 4 ~ 20mA DC / DC voltage: 0 ~ 1V DC, 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC

Within ± 0.2 %± 1 digit or within ± 2 ° C (4 ° F) of each input span

Within ± 0.1 %± 1 digit or within ± 1 ° C (2 ° F) of each input span

Within ± 0.2 %± 1 digit of each input span

125ms

Auto tuning PID, PI, PD, P, ON/OFF

Non -contact voltage

100 ~ 240V AC 50/60Hz

-

Warning output, loop anomalous alarm output

・ However, 0 to 200 ° C (32-392 ° F) of R and S input within ± 6 ° C (12 ° F) ・ B 0 to 300 ° C (32 to 572 ° F) outside the precision guarantee range.

・ K, J, E, T, N's input is less than 0 ° C (32 ° F), within ± 0.4 % ± 1 digit or ± 4 ° C (8 ° F) of the input span or ± 4 ° C (8 ° F).

DIN rail mounting type digital instruction adjustment meter DCL-33A-Part Number-DCL-33A-S/M 1

DCL-33A-S/M 1

Available upon quote

・ Thermal electricity vs.: K, J, S, S, B, T, N, PL-II, C (W/Re5-26) ・ Temperature resistance body: PT100, JPT100 ・ DC current: 0 ~ 20mA DC, 4 ~ 20mA DC / DC voltage: 0 ~ 1V DC, 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC

Within ± 0.2 %± 1 digit or within ± 2 ° C (4 ° F) of each input span

Within ± 0.1 %± 1 digit or within ± 1 ° C (2 ° F) of each input span

Within ± 0.2 %± 1 digit of each input span

125ms

Auto tuning PID, PI, PD, P, ON/OFF

Non -contact voltage

24V AC/DC 50/60Hz

-

Warning output, loop anomalous alarm output

・ However, 0 to 200 ° C (32-392 ° F) of R and S input within ± 6 ° C (12 ° F) ・ B 0 to 300 ° C (32 to 572 ° F) outside the precision guarantee range.

・ K, J, E, T, N's input is less than 0 ° C (32 ° F), within ± 0.4 % ± 1 digit or ± 4 ° C (8 ° F) of the input span or ± 4 ° C (8 ° F).

DIN rail mounting type digital instruction adjustment meter DCL-33A-Part Number-DCL-33A-A/M

DCL-33A-A/M

Available upon quote

・ Thermal electricity vs.: K, J, S, S, B, T, N, PL-II, C (W/Re5-26) ・ Temperature resistance body: PT100, JPT100 ・ DC current: 0 ~ 20mA DC, 4 ~ 20mA DC / DC voltage: 0 ~ 1V DC, 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC

Within ± 0.2 %± 1 digit or within ± 2 ° C (4 ° F) of each input span

Within ± 0.1 %± 1 digit or within ± 1 ° C (2 ° F) of each input span

Within ± 0.2 %± 1 digit of each input span

125ms

Auto tuning PID, PI, PD, P, ON/OFF

DC current

100 ~ 240V AC 50/60Hz

-

Warning output, loop anomalous alarm output

・ However, 0 to 200 ° C (32-392 ° F) of R and S input within ± 6 ° C (12 ° F) ・ B 0 to 300 ° C (32 to 572 ° F) outside the precision guarantee range.

・ K, J, E, T, N's input is less than 0 ° C (32 ° F), within ± 0.4 % ± 1 digit or ± 4 ° C (8 ° F) of the input span or ± 4 ° C (8 ° F).

DIN rail mounting type digital instruction adjustment meter DCL-33A-Part Number-DCL-33A-A/M 1

DCL-33A-A/M 1

Available upon quote

・ Thermal electricity vs.: K, J, S, S, B, T, N, PL-II, C (W/Re5-26) ・ Temperature resistance body: PT100, JPT100 ・ DC current: 0 ~ 20mA DC, 4 ~ 20mA DC / DC voltage: 0 ~ 1V DC, 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC

Within ± 0.2 %± 1 digit or within ± 2 ° C (4 ° F) of each input span

Within ± 0.1 %± 1 digit or within ± 1 ° C (2 ° F) of each input span

Within ± 0.2 %± 1 digit of each input span

125ms

Auto tuning PID, PI, PD, P, ON/OFF

DC current

24V AC/DC 50/60Hz

-

Warning output, loop anomalous alarm output

・ However, 0 to 200 ° C (32-392 ° F) of R and S input within ± 6 ° C (12 ° F) ・ B 0 to 300 ° C (32 to 572 ° F) outside the precision guarantee range.

・ K, J, E, T, N's input is less than 0 ° C (32 ° F), within ± 0.4 % ± 1 digit or ± 4 ° C (8 ° F) of the input span or ± 4 ° C (8 ° F).

DIN rail mounting type digital instruction adjustment meter DCL-33A-Part Number-DCL-33A-R/M, W (5A)

DCL-33A-R/M, W (5A)

Available upon quote

・ Thermal electricity vs.: K, J, S, S, B, T, N, PL-II, C (W/Re5-26) ・ Temperature resistance body: PT100, JPT100 ・ DC current: 0 ~ 20mA DC, 4 ~ 20mA DC / DC voltage: 0 ~ 1V DC, 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC

Within ± 0.2 %± 1 digit or within ± 2 ° C (4 ° F) of each input span

Within ± 0.1 %± 1 digit or within ± 1 ° C (2 ° F) of each input span

Within ± 0.2 %± 1 digit of each input span

125ms

Auto tuning PID, PI, PD, P, ON/OFF

Relay contact

100 ~ 240V AC 50/60Hz, 24V AC/DC 50/60Hz

Hita disconnection alert

Warning output, loop anomalous alarm output

・ However, 0 to 200 ° C (32-392 ° F) of R and S input within ± 6 ° C (12 ° F) ・ B 0 to 300 ° C (32 to 572 ° F) outside the precision guarantee range.

・ K, J, E, T, N's input is less than 0 ° C (32 ° F), within ± 0.4 % ± 1 digit or ± 4 ° C (8 ° F) of the input span or ± 4 ° C (8 ° F).

DIN rail mounting type digital instruction adjustment meter DCL-33A-Part Number-DCL-33A-R/M 1, W (5A)

DCL-33A-R/M 1, W (5A)

Available upon quote

・ Thermal electricity vs.: K, J, S, S, B, T, N, PL-II, C (W/Re5-26) ・ Temperature resistance body: PT100, JPT100 ・ DC current: 0 ~ 20mA DC, 4 ~ 20mA DC / DC voltage: 0 ~ 1V DC, 0 ~ 5V DC, 1 ~ 5V DC, 0 ~ 10V DC

Within ± 0.2 %± 1 digit or within ± 2 ° C (4 ° F) of each input span

Within ± 0.1 %± 1 digit or within ± 1 ° C (2 ° F) of each input span

Within ± 0.2 %± 1 digit of each input span

125ms

Auto tuning PID, PI, PD, P, ON/OFF

Relay contact

24V AC/DC 50/60Hz

Hita disconnection alert

Warning output, loop anomalous alarm output

・ However, 0 to 200 ° C (32-392 ° F) of R and S input within ± 6 ° C (12 ° F) ・ B 0 to 300 ° C (32 to 572 ° F) outside the precision guarantee range.

・ K, J, E, T, N's input is less than 0 ° C (32 ° F), within ± 0.4 % ± 1 digit or ± 4 ° C (8 ° F) of the input span or ± 4 ° C (8 ° F).

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Controllers Products

Other products of Shinko Technos Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Shinko Technos Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

53.0hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree