Product
Program controller PCB1Handling Company
Shinko Technos Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Cold junction compensation accuracy | Control output DC current | Control output OUT2 (optional) DC current | Control output OUT2 (optional) Non-contact voltage | Control output OUT2 (optional) Relay contact 1a | Control output non-contact voltage (for SSR drive) | Control output relay contact 1a | Event input (optional) Closed circuit current | Event input (optional) Determination of operation | Event input (optional) Number of input points | Event output EV1 to EV3 relay contact 1a | Input DC current | Input DC voltage | Input resistance thermometer | Input sampling period | Input thermocouple | Isolated power output (optional) Maximum load current | Isolated power output (optional) Output voltage | Isolated power output (optional) ripple voltage | Setting accuracy | Setting resolution temperature | Standard accuracy DC current DC voltage | Standard accuracy resistance thermometer | Standard accuracy thermocouple | Time indication accuracy | Time setting accuracy | Transmission output (optional) Output accuracy | Transmission output (optional) output | Transmission output (optional) resolution | Transmission output (optional) response time |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PCB1 |
Available upon quote | Within ±1℃ from 0 to 50℃ | 4-20mADC resolution 12,000 load resistance up to 550Ω | 4-20mADC resolution 12,000 load resistance up to 550Ω | 12VDC±15% max. 40mA (with short circuit protection) |
Control capacity 3 A 250 V AC (resistive load) 1A 250V AC (inductive load cos=0.4) Electrical life 100,000 times Minimum applicable load 10 mA 5 V DC |
12VDC±15% max. 40mA (with short circuit protection) |
Control capacity 3A25 VAC (resistive load) 1A250VAC (inductive load cosΦ=0.4) Electrical life 100,000 times Minimum applicable load 10mA5VDC |
Approximately 16mA | Edge operation Determined by level operation when power is turned on | 2 points | Control capacity 3A250VAC (resistive load) 1A250VAC (inductive load cosΦ=0.4) Electrical life 100,000 times Minimum applicable load 10mA5VDC | 0~20mADC, 4~20mADC input impedance 50Ω Allowable input current 50mA or less | 0~1VDC input impedance: 1ΩM or more Allowable input voltage: 5VDC or less Allowable signal source resistance: 2kΩ or less | Pt100, JPt1003 conductor type Allowable input conductor resistance: Resistance per wire 10Ω or less | 125ms | K, J, R, S, B, E, T, N, PL-Ⅱ, C (W/Re5-26) External resistance 100Ω or less, however, B is 40Ω or less | 30mADC | 24V±3VDC (at load current 30mADC) | Within 200mVDC (at load current 30mADC) | Based on standard accuracy and cold junction compensation accuracy | Thermocouple, RTD input without decimal point: 1°C (F) Thermocouple, RTD input with decimal point: 0.1°C (F) DC voltage, DC current input: 1 | Within ±0.2% ±1 digit of each input span | Within ±0.1% ±1 digit of each input span |
Within ±0.2%±1 digit of each input span However, R, S input 0 to 200℃ (32 to 392F) is within 6℃ (12F) B input 0 to 300℃ (0 to 572F) is outside the guaranteed accuracy range |
±10.1% of setting time | ±0.1% of setting time | Within ±0.3% of transmission output span | 4~20mADC (load resistance: max. 550Ω) | 12,000 | 400ms+input sampling period (0%→90%) |