Program controller PCA1-PCA1
Program controller PCA1-Shinko Technos Co., Ltd.

Program controller PCA1
Shinko Technos Co., Ltd.


About This Product

■Summary A program controller that can set 16 patterns and 16 steps, a maximum of 256 steps. ■Program capacity 16 patterns 16 steps - Program capacity is 16 patterns and 16 steps. - By connecting patterns, program control of up to 256 steps is possible. Improved visibility with 11 segment LCD display ■Adopts 11 segment LCD display Setting characters are now easier to understand. ■The largest size in the industry. PV display: 24.0 x 11.0mm (height x width). SV/MV/TIME display: 14.0 x 7.0mm (height x width) ■PV-linked display color switching Equipped with a function that changes the PV display color from orange to green to red, from green to red when alarm is ON, from orange to red when alarm is ON, or by changing the PV display color depending on the deviation between PV and SV. In conjunction with the operation indicator light, you can easily check for abnormalities. ■Program capacity is 16 patterns and 16 steps. By linking patterns, program control of up to 256 steps is possible. ■Console software contributes to labor savings The console software (SWC-PCA101M) improves the operability of initial settings and contributes to labor savings. If you use the USB communication cable (CMB-001), there is no need to power the PCA1. ■“Visualize” data with monitor software By using the monitor software (SWM-PCA101M), you can change item settings, data logging, monitoring, etc. on your computer. ■Serial communication function improved In addition to our standard protocols, communication protocols support ModbusASCII and ModbusRTU. ModbusASCII and ModbusRTU support block read/write and can read/write multiple data at up to 100 points. ■Dustproof/splashproof structure The front part has an IP66 structure that can be used even in harsh environments where it is exposed to dust and water.

  • Product

    Program controller PCA1

Share this product


20+ people viewing

Last viewed: 9 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Program controller PCA1

Product Image Part Number Price (excluding tax) Cold junction compensation accuracy Control output DC current Control output non-contact voltage (for SSR drive) Control output relay contact 1a1b Event output EV1 to EV4 relay contact 1a H (mm) Input DC current Input DC voltage Input resistance thermometer Input sampling period Input thermocouple Number of patterns Number of steps Program time range Repeat count Setting resolution Setting temperature Setting resolution time Standard accuracy measurement DC current DC voltage Standard accuracy resistance thermometer Standard accuracy thermocouple Time indication accuracy W (mm) Weight value
Program controller PCA1-Part Number-PCA1

PCA1

Available upon quote Within ±1℃ from 0 to 50℃ 4-20mADC resolution 12,000 load resistance up to 600Ω 12VDC±15% max. 40mA (with short circuit protection) Control capacity 3A250VAC (resistive load) 1A250VAC (inductive load cosΦ=0.4) Electrical life 100,000 times Control capacity 3A250VAC (resistive load) 1A250VAC (inductive load cosΦ=0.4) Electrical life 100,000 times Event output One side of EV3 and EV4 is a common terminal 96 0~20mADC, 4~20mADC input impedance 50Ω Allowable input current 100mA or less 0 to 10mVDC, -10 to 10mVDC, 0 to 50mVDC, 0 to 100mVDC, 0 to 1VDC Input impedance 1ΩM or more Allowable input voltage 5VDC or less Allowable signal source resistance 2kΩ or less (0 to 1VDC) Pt100, JPt1003 conductor type allowable input conductor resistance resistance per wire 10Ω or less However, PT100-100.0 to 100.0 is 5Ω or less 125ms K, J, R, S, B, E, T, N, PL-Ⅱ, C (W/Re5-26) External resistance 100Ω or less However, for B input, external resistance 40Ω or less 16 patterns (can be connected) 256 (16 steps/pattern) 0 to 99 hours 59 minutes/step or 0 to 99 minutes 59 seconds/step (If you set -----, fixed value control is performed with step SV) 0 to 9,999 times (If set to 0, repeat operation will not occur) Thermocouple, RTD input without decimal point: 1°C (F) Thermocouple, RTD input with decimal point:
0.1℃ (F) For DC voltage and DC current input: 1
1 minute or 1 second Within ±0.2% ±1 digit of each input span Within ±0.1% ±1 digit of each input span Within ±0.2% ±1 digit of each input span However, R and S inputs 0 to 200°C (32 to 392F) are within 6°C (12F) B inputs 0 to 300°C (0 to 572F) are outside the guaranteed accuracy range ±0.1% of setting time 96 Thermocouple, RTD input without decimal point: ± (0 to 100) °C (F) Thermocouple, RTD input with decimal point: ± (0.0 to 100.0) °C (F)