Air leak tester standard type for battery and valve manufacturing FLS-0100 series differential pressure type (with linear fitting function)Handling Company
FUKUDA CO., LTD.Categories
Image | Part Number | Price (excluding tax) | Power supply voltage | Quantity quality | Measurement method | Power consumption | Contact specifications | Differential pressure sensor specifications | External dimensions (mm) *Excluding protrusions | Pressure setting range Setting pressure range | Pressure setting range Display pressure range | Pressure setting range Working pressure range | Pressure range | Additional specifications | Gauge pressure sensor specification accuracy |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FLS-0100-VB02010202XXXXNNNN |
Available upon quote |
AC100V~240V50/60Hz |
Approximately 13kg |
Workpiece/workpiece comparison, workpiece/master comparison, workpiece/fixed master comparison, differential pressure leak tester |
Approximately 100VA |
NPN input/output |
±2kPa |
W162×D344×H256 |
-90.0~0.0kPa |
-99.9~0.0kPa |
-90.0~5.0kPa |
-90kPa~99.9kPa |
No settings |
±2%F.S. (Pressure range VB,LC,LJ,LD,LE), ±1%F.S. (Pressure range LF,MC,HC) |