All Categories

History

Air leak tester standard type general purpose type (compatible with high pressure tests) FL-611 series-FL-610VB-02-01-02-02-NN-NN-D14-0901-01
Air leak tester standard type general purpose type (compatible with high pressure tests) FL-611 series-FUKUDA CO., LTD.

Air leak tester standard type general purpose type (compatible with high pressure tests) FL-611 series
FUKUDA CO., LTD.

FUKUDA CO., LTD.'s Response Status

Response Rate

100.0%

Response Time

52.5hours


About This Product

■What is an air leak tester?

This tester uses air to pressurize the inside (or outside) of a sealed workpiece and determines leakage based on the pressure change. When pressurizing a leak-free master and a leaking work, the pressure on the leaking work will decrease, creating a pressure difference between the master and the work. Leakage is determined by looking at this pressure difference. This differential pressure type air leak test is generally used to check for leaks, but at Fukuda, in addition to the differential pressure type leak tester, we also have products that use direct pressure type leak tests and flow meters in line with the leak rate (leakage amount). It is up. Additionally, since the medium used for testing is air, there are no running costs and the tester does not pollute the environment. A general-purpose air leak tester that can be used in a wide variety of measurement environments. It has a correction function that is strong against fluctuations in the measurement environment, allowing stable measurements. By using the circuit switching unit (model: ESV), you can easily measure multiple workpieces with one tester. By connecting an electro-pneumatic regulator (model: APU control repeatability ±0.1%), rapid pressurization can shorten measurement time and improve measurement accuracy by stabilizing supply pressure.

■Specifications

- Resistant to fluctuations in measurement environment -Various screen displays (waveform display, process display, results list, etc.) ・Data comparison measurement that does not require master (good product) is possible ・Equipped with USB terminal

■General-purpose type

A high-performance model that can flexibly respond to various measurement conditions and measurement workpieces.

■Measurement without master work is also possible

By using the correction function, it is also possible to make judgments based on data standards without the need for master work.

■High accuracy/shortened measurement time

By building standard data and comparing it with measured data, detection accuracy is improved and the presence or absence of leaks can be determined in a short time. High pressure compatible (~5MPa)

■Equipped with USB terminal

Easy data input/output Test results can be stored and managed using USB memory

■Supports a wide variety of products

32 types of measurement conditions can be set

■Large color display adopted

Process display, waveform display, and data analysis during measurement can be performed on the display screen.

■Work/master comparison measurement

This is a normal differential pressure leak tester. Good products are judged based on the pressure difference between the reference master work and the work to be measured.

■Linear fitting measurement

By connecting a master tank (stable tank) instead of the master and using the correction function, master stage change process and master management are no longer necessary. Large workpieces and easily deformable workpieces can be measured in a short time.

  • Product

    Air leak tester standard type general purpose type (compatible with high pressure tests) FL-611 series

Share this product


50+ people viewing

Last viewed: 15 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Air leak tester standard type general purpose type (compatible with high pressure tests) FL-611 series

Image Part Number Price (excluding tax) Power supply voltage Mass Special specifications Power consumption Contact specifications Differential pressure sensor External dimensions (mm) *Excluding protrusions External options power cord Pressure setting range Setting pressure range Pressure setting range Display pressure range Pressure setting range Working pressure range Pressure range Additional specifications Gauge pressure sensor
Air leak tester standard type general purpose type (compatible with high pressure tests) FL-611 series-Part Number-FL-610VB-02-01-02-02-NN-NN-D14-0901-01

FL-610VB-02-01-02-02-NN-NN-D14-0901-01

Available upon quote

AC100~240V

Approximately 12kg

None

100VA

NPN input/output

2kPa

W162×D344×H256

3m125V-7A 3-pole plug conversion plug for Japan

-90.0~0.0kPa

-99.9~0.0kPa

-90.0-5.0kPa

-90kPa~5.0MPa

None

±2%F.S.

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Air Leak Testers Products

Other products of FUKUDA CO., LTD.

Reviews shown here are reviews of companies.


View more products of FUKUDA CO., LTD.

About Company Handling This Product