Medical AC DC Adapter Waterproof Desktop Adapter FWM120Handling Company
FranMar International Inc.Categories
Image | Part Number | Price (excluding tax) | Power derating | Overvoltage protection | Overheating protection | Transient response | Withstand voltage | Inrush current | Short circuit protection | Relative humidity | Leakage current | Temperature coefficient | Temperature derating | Maximum output power | Atmospheric pressure | Operating temperature | Efficiency | Power factor | Output voltage | Input current (rms) | Input voltage | Input frequency | Storage temperature | Intrusion protection | Ripple and noise | Line regulation | Hold up time | Touch current | Switching frequency | MTBF | EN61000-3-2 | EN55011 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FWM120-S120-x |
Available upon quote |
Derates linearly from 100% at 90VAC to 90% at 85VAC to 80% at 80VAC. |
112%~140% |
Latch with recycle input to reset |
Excursion up to 4% or more for all models, recovery to 1% of final value within 500us after 25% step load change |
4,000VAC (2MOPP) from input to output |
90A@115VAC or 180A@230VAC, 25℃ cold star |
Automatic recovery |
5% to 95% non-condensing |
Up to 180μA @ 264VAC, 63Hz |
Maximum ±0.04%/℃ |
Linear derating from 100% at +40°C to 50% at +60°C |
96~120W |
540hPa~1,060hPa |
-20℃~+60℃ |
88% or more at full load |
0.98 standard 115VAC |
12~48VDC |
1.60A (rms) for 115VAC, 0.80A (rms) for 230VAC |
80~264VAC |
47~63Hz |
-40℃~+85℃ |
IP54 |
1% peak-to-peak maximum |
Maximum ±0.5% at full load |
20ms minimum at 100VAC |
Up to 100μA @ 264VAC, 63Hz |
50~130KHz |
100,000 hours at full load at 25°C ambient temperature, calculated according to MIL-HDBK-217F |
Harmonic distortion, class A and D |
Class B was conducted and Class B was radiated |