Product
15W Medical AC Adapter HPU15Handling Company
TokitradingItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Appearance dimensions | Input voltage | MTBF | Maximum output | Operating temperature | Operation humidity | Output current | Output voltage | Storage and humidity | Storage temperature | Tr |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HPU15-101 |
Available upon quote | L60 X W43.5 x H40.2 mm | 80-275vac | 100,000 hours (calculated value) | 7.2W | -10 ° C to 70 ° C (due to danger) | 0% to 95% (no water drops) | 1.44-2.40A | 3-4.99VDC | 0% to 95% (no water drops) | -40 ° C to 85 ℃ | Five% | |
HPU15-102 |
Available upon quote | L60 X W43.5 x H40.2 mm | 80-275vac | 100,000 hours (calculated value) | 12W | -10 ° C to 70 ° C (due to danger) | 0% to 95% (no water drops) | 2.00-2.40A | 5-5.99VDC | 0% to 95% (no water drops) | -40 ° C to 85 ℃ | Five% | |
HPU15-103 |
Available upon quote | L60 X W43.5 x H40.2 mm | 80-275vac | 100,000 hours (calculated value) | 12W | -10 ° C to 70 ° C (due to danger) | 0% to 95% (no water drops) | 1.50-1.84A | 6.5-8VDC | 0% to 95% (no water drops) | -40 ° C to 85 ℃ | Five% | |
HPU15-104 |
Available upon quote | L60 X W43.5 x H40.2 mm | 80-275vac | 100,000 hours (calculated value) | 13.5W | -10 ° C to 70 ° C (due to danger) | 0% to 95% (no water drops) | 1.22-1.68a | 8-11VDC | 0% to 95% (no water drops) | -40 ° C to 85 ℃ | Five% | |
HPU15-105 |
Available upon quote | L60 X W43.5 x H40.2 mm | 80-275vac | 100,000 hours (calculated value) | 15W | -10 ° C to 70 ° C (due to danger) | 0% to 95% (no water drops) | 1.15-1.36A | 11-13VDC | 0% to 95% (no water drops) | -40 ° C to 85 ℃ | Five% | |
HPU15-106 |
Available upon quote | L60 X W43.5 x H40.2 mm | 80-275vac | 100,000 hours (calculated value) | 15W | -10 ° C to 70 ° C (due to danger) | 0% to 95% (no water drops) | 0.94-1.15A | 13-16VDC | 0% to 95% (no water drops) | -40 ° C to 85 ℃ | Five% | |
HPU15-107 |
Available upon quote | L60 X W43.5 x H40.2 mm | 80-275vac | 100,000 hours (calculated value) | 15W | -10 ° C to 70 ° C (due to danger) | 0% to 95% (no water drops) | 0.72-0.94A | 16-21VDC | 0% to 95% (no water drops) | -40 ° C to 85 ℃ | Five% | |
HPU15-108 |
Available upon quote | L60 X W43.5 x H40.2 mm | 80-275vac | 100,000 hours (calculated value) | 15W | -10 ° C to 70 ° C (due to danger) | 0% to 95% (no water drops) | 0.55-0.72A | 21-27VDC | 0% to 95% (no water drops) | -40 ° C to 85 ℃ | Five% | |
HPU15-109 |
Available upon quote | L60 X W43.5 x H40.2 mm | 80-275vac | 100,000 hours (calculated value) | 15W | -10 ° C to 70 ° C (due to danger) | 0% to 95% (no water drops) | 0.45-0.55A | 27-33VDC | 0% to 95% (no water drops) | -40 ° C to 85 ℃ | 3% | |
HPU15-110 |
Available upon quote | L60 X W43.5 x H40.2 mm | 80-275vac | 100,000 hours (calculated value) | 15W | -10 ° C to 70 ° C (due to danger) | 0% to 95% (no water drops) | 0.37-0.45a | 33-40VDC | 0% to 95% (no water drops) | -40 ° C to 85 ℃ | 3% | |
HPU15-111 |
Available upon quote | L60 X W43.5 x H40.2 mm | 80-275vac | 100,000 hours (calculated value) | 15W | -10 ° C to 70 ° C (due to danger) | 0% to 95% (no water drops) | 0.32-0.37A | 40-48VDC | 0% to 95% (no water drops) | -40 ° C to 85 ℃ | 3% | |
HPU15-112 |
Available upon quote | L60 X W43.5 x H40.2 mm | 80-275vac | 100,000 hours (calculated value) | 15W | -10 ° C to 70 ° C (due to danger) | 0% to 95% (no water drops) | 0.28-0.32A | 48-55VDC | 0% to 95% (no water drops) | -40 ° C to 85 ℃ | 3% |
Click on the part number for more information about each product