Harmonic suppression unit HS910-015LF-HS910-015LF
Harmonic suppression unit HS910-015LF-Fuji Electrode Industry Co., Ltd.

Harmonic suppression unit HS910-015LF
Fuji Electrode Industry Co., Ltd.


About This Product

It makes the input current waveform sinusoidal and reduces and suppresses harmonics generated from the inverter. It also helps improve the power factor. Energy can be saved by returning the regenerated energy from the motor to the power supply. The HS910 series is equipped with communication functions and life detection functions to improve ease of use. In addition, the stability of the generator combination operation has been improved compared to the previous model, and it has achieved tenacious operation. ■Make the input current waveform sinusoidal to reduce and suppress the generation of harmonics. When using a harmonic suppression unit, the power supply circuit of the harmonic suppression countermeasure guidelines is treated as conversion factor K5=0. The problem that peak current occurs in the input current when using only an inverter is improved by making the input current into a sine wave shape and suppressing the generation of harmonics. Additionally, controlling at a power factor of 1 helps improve the power factor, making it possible to downsize power supply equipment. ■Input current waveform is sinusoidal A common converter can be used, and inverters can be connected in parallel. Multiple inverters can be connected in parallel to create a common converter. Separate regenerative braking units are not required and harmonics can be suppressed all at once, saving space and reducing costs. ■ Energy savings can be achieved by returning regenerated energy to the power source. When using a braking resistor, the regenerated energy from the motor is dissipated as thermal energy. Systems using HS910 save energy by returning regenerated energy to the power source and reusing it. Continuous regeneration is possible at 100% of the rated value, and it can also be used in systems with sudden deceleration and frequent acceleration/deceleration.

  • Product

    Harmonic suppression unit HS910-015LF

Share this product


20+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Harmonic suppression unit HS910-015LF

Product Image Part Number Price (excluding tax) Control method Harmonic suppression Input power factor Mass Maximum connected motor capacity (kW) Overload capacity Protective structure Rated current (A) Rated input AC voltage
Harmonic suppression unit HS910-015LF-Part Number-HS910-015LF

HS910-015LF

Available upon quote Sine wave PWM (current control type voltage command method) Compatible with harmonic guideline K5=0 0.99 or more (at 100% load factor) 3kg 1.5 150% for 1 minute IP00 6.1 50Hz (±5%) 200~220V±10%/60Hz (±5%) 200~230V±10%