This is an electromagnetic flow sensor for medicinal fluids that can measure even pulsating flows. Compact electromagnetic flow sensor for medicinal fluids VNSHandling Company
Aichi Watch Electric Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Measuring fluid | Pulsation measurement mode specifications Guaranteed accuracy flow rate range | Pulsation measurement mode specifications Target pump | Pulsation measurement mode specifications Aperture | Pulsation measurement accuracy (fluid temperature: 25℃) Frequency pulse | Fluid temperature range | Fluid conductivity range | Maximum working pressure | Responsiveness | Steady flow measurement mode specifications Guaranteed accuracy flow rate range | Steady flow measurement mode specifications Low flow cutoff (standard) | Steady flow accuracy (fluid temperature: 25℃) Frequency pulse | Steady flow accuracy (fluid temperature: 25℃) Unit pulse | Pressure loss (at maximum flow rate with guaranteed accuracy) | Output 2 alarm | Output 2 unit pulse | Output 2 Output specifications | Output 2 switch | Output 1 alarm | Output 1 frequency pulse | Output 1 unit pulse | Output 1 Output specifications | Output 1 switch | Storage ambient temperature range | Operating ambient temperature/humidity range | Cable wiring ASI-200 | Cable Wiring ASI-100 or general purpose receiver | Cable basic specifications | LED display | ASSP serial communication |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VNS05RF |
Available upon quote |
Sodium hypochlorite aqueous solution “concentration 1-12%” |
0.01~1L/min |
Electromagnetic (solenoid) diaphragm metering pump only |
5mm |
・±5.0%RD: 20~100% of the maximum flow rate with guaranteed accuracy |
0~+40℃ (Do not freeze) |
14mS/cm or more |
1MPa |
・63% response Damping time: 2 seconds (standard) |
0.05~1L/min |
0.025L/min |
・±2.5%RD: 20~100% of the maximum flow rate with guaranteed accuracy |
・±2.0%RD: 20~100% of the maximum flow rate with guaranteed accuracy |
20kPa or less |
Normally open (standard) - Select from normally closed Alarm items of "Excitation abnormality/Memory abnormality/Low power supply voltage/Dry water/Excessive fluid noise/Reverse flow/Excessive flow rate" can be set at the time of shipment. |
0.001L/P (standard) |
・NPN open collector pulse |
Select from Normally Open (Standard) / Normally Closed Level or Window Judgment Value: Can be set at factory from 0 to 100% of the guaranteed maximum flow rate in 1% steps |
Normally open (standard) - Select from normally closed Alarm items of "Excitation abnormality/Memory abnormality/Low power supply voltage/Dry water/Excessive fluid noise/Reverse flow/Excessive flow rate" can be set at the time of shipment. |
Standard 200.0Hz (can be set in 0.1Hz steps between 20 and 400Hz at the time of shipment) Note: When connecting ASI-100 and ASI-200, we recommend output 1 to be 200.0Hz. |
0.001L/P (standard) |
・NPN open collector pulse |
Select from Normally Open (Standard) / Normally Closed Level or Window Judgment Value: Can be set at factory from 0 to 100% of the guaranteed maximum flow rate in 1% steps |
-20~+70℃ |
-20~+60℃ 35~85%RH (no condensation) |
Red: Power + Blue: GND White: Transmission line Yellow: Reception line |
Red: Power + Blue: GND White: Output 1 Yellow: Output 2 |
Cable length: Approx. 500mm 4 cores AWG26 outer diameter Φ4.2 with shield |
・One LED display on the sensor body 2-color LED (green/red) |
・ON resistance: 200Ω or less, OFF resistance: 100kΩ or more |