All Categories
History
Product
This is an electromagnetic flow sensor with no moving parts that is suitable for integration into equipment. Compact electromagnetic flow sensor VNHandling Company
Aichi Watch Electric Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Power supply | Piping connections | Measuring fluid | Accuracy guaranteed flow range | Accuracy (at fluid temperature 25℃) Frequency pulse | Accuracy (at fluid temperature 25℃) Unit pulse | Current consumption | Fluid temperature range | Fluid conductivity range | Maximum working pressure | Maximum operating flow rate | Responsiveness | Pressure loss (at maximum flow rate with guaranteed accuracy) | Caliber | Mounting position | Output 2 alarm | Output 2 unit pulse | Output 2 Output specifications | Output 2 switch | Output 1 alarm | Output 1 frequency pulse | Output 1 unit pulse | Output 1 Output specifications | Output 1 switch | Protective structure | Storage ambient temperature range | Operating ambient temperature/humidity range | Low flow cutoff | Cable | LED display |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VN05R |
Available upon quote |
12~24V DC±10% |
R1/4 |
Conductive fluid that does not corrode wetted parts (cold and hot water, etc.) |
0.05~1L/min |
・±2.5%RD: 20~100% of the maximum flow rate with guaranteed accuracy |
・±2.0%RD: 20~100% of the maximum flow rate with guaranteed accuracy |
100mA DC or less |
0~+60℃ (Do not freeze) |
50μS/cm or more |
1MPa |
3L/min |
63% response Damping time: 2 seconds (standard) Can be set in 1 second steps from 1 to 99 seconds at the time of shipment |
20kPa or less |
5mm |
Free (no gas contamination) |
Normally open (standard) - Select from normally closed Alarm items of "Excitation abnormality/Memory abnormality/Low power supply voltage/Dry water/Excessive fluid noise/Reverse flow/Excessive flow rate" can be set at the time of shipment. |
0.001L/P (standard) |
・NPN open collector pulse |
Select from Normally Open (Standard) / Normally Closed Level or Window Judgment Value: Can be set at factory from 0 to 100% of the guaranteed maximum flow rate in 1% steps |
Normally open (standard) - Select from normally closed Alarm items of "Excitation abnormality/Memory abnormality/Low power supply voltage/Dry water/Excessive fluid noise/Reverse flow/Excessive flow rate" can be set at the time of shipment. |
Standard 200.0Hz (can be set in 0.1Hz steps between 20 and 400Hz at the time of shipment) Note: When connecting ASI-100, select 200.0Hz for output 1. |
0.001L/P (standard) |
・NPN open collector pulse |
Select from Normally Open (Standard) / Normally Closed Level or Window Judgment Value: Can be set at factory from 0 to 100% of the guaranteed maximum flow rate in 1% steps |
Indoor specification (IP64) |
-20~+70℃ |
-20~+60℃ 35~85%RH (No condensation) |
0.025L/min |
Cable length: Approx. 500mm 4 cores AWG28 outer diameter Φ2.8 with shield |
・One LED display on the sensor body 2-color LED (green/red) |