All Categories

History

New electromagnetic flowmeter Water maX WX-WX50
New electromagnetic flowmeter Water maX WX-Aichi Watch Electric Co., Ltd.

New electromagnetic flowmeter Water maX WX
Aichi Watch Electric Co., Ltd.


About This Product

This is an electromagnetic flowmeter exclusively for water. Equipped with functions required for water management needs, it is ideal for factory visualization and usage management. This is a user-friendly flowmeter that takes into consideration operability and visibility. Features

■Intuitive display

We have designed it to be easy to understand and read. The main display can be changed to suit your usage.

■Water leak detection

If the flow rate continues to flow within the set range for one hour, it is determined that there is a "leak" and an alarm display and contact are output. *This function is set to OFF at the time of shipment.

■Backflow measurement

Both display and output support backflow measurement. Ideal for back cleaning management of reverse osmosis (RO) membranes, etc. *Backflow measurement is a guideline and accuracy is not guaranteed. *This function is set to OFF at the time of shipment.

■Medicine injection pulse

It also supports pulse output in units of 5L (50-80mm) and 50L (100-200mm), which is required for drug dosing.

■Simulated output

Analog pulses (fixed value) can be output by button operation without running water. Convenient for checking the wiring with the receiver. ・Analog: 12mA ・Pulse: 5 or 10Hz

■For various water management in factories

・Management of pumping amount of well water/river water ・Backwashing management of reverse osmosis (RO) membranes ・Lower limit flow detection ・Management of supplementary water in cooling towers ・Management of wastewater treatment ・Flow rate control of treated water (pump control) ・Water supply management to boiler accuracy

■If the full scale flow rate setting is 3 m/s equivalent flow rate or higher

・±1.0%RD: 1/2 of full scale setting value to full scale setting value ・±0.5% FS: Zero cut flow rate to 1/2 of full scale setting value

■If the full scale flow rate setting is less than 3m/s equivalent flow rate (3m/s equivalent flow rate is 100% FS)

・±1.0%RD: 1/2 to 3m/s equivalent flow rate of 3m/s equivalent flow rate ・±0.5% FS: Zero cut flow rate ~ 1/2 of 3 m/s equivalent flow rate

  • Product

    New electromagnetic flowmeter Water maX WX

Share this product


70+ people viewing

Last viewed: 2 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of New electromagnetic flowmeter Water maX WX

Image Part Number Price (excluding tax) Power supply Mass Measuring fluid temperature Display integrated value Display Instantaneous value Display Others Accuracy 3m/s equivalent flow rate Power consumption Material ○: Wetted part Connection method Conductivity Caliber Output pulse Output analog Protective structure Operating environment temperature and humidity Maximum pressure used Memory backup Full scale flow rate setting range Display screen Damping (63% response) Zero cut flow rate Accessories
New electromagnetic flowmeter Water maX WX-Part Number-WX50

WX50

Available upon quote

24VDC±10%

Approximately 3kg

0℃~+60℃ (temporarily 70℃) No freezing

・999,999.999m3 (L and kL can also be set)
・Total integrated value, trip integrated value, reverse flow integrated value, forward and reverse integrated value

19,999L/min (m3/h can also be set)

Alarm (memory error, backflow, excessive noise, dry water, power supply voltage drop, water leakage, overcurrent), flow rate L/s, indicator (10-level display)

360L/min

Approx. 6W (power supply current 250mA, peak inrush current 10A or less when power is turned on)

・Converter part: ADC12, tempered glass
・Housing: SUS304
・○Lining: Fluororesin
・○Measuring tube: SUS316
・○ Electrode: SUS316L
・○Gasket: EPDM

Wafer

20μs/cm or more

50mm

・2 points NPN transistor output
・Rating 28VDC 80mA N.O (N.C can also be set)
・ON time: 50±5msec
・Output contents (factory setting) Contact 1: Accumulated pulse, Contact 2: Alarm

1 point 4~20mA (clip at upper limit 110%, maximum load 500Ω or less)

IP64

-10℃~+55℃ 5~95%RH No freezing or condensation, avoid direct sunlight.

50~150mm: 2MPa, 200mm: 1MPa

Integrated value: 2 minute intervals, set value: when changing settings

15~950L/min

128×64 full dot LCD LED white backlight

5sec (0.5sec, 1sec, 10sec, 30sec, 100sec, 200sec can also be set)

20L/min

Installation set (bolts and nuts) *The gasket is glued to the flowmeter.

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Flowmeters Products

Other products of Aichi Watch Electric Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Aichi Watch Electric Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree