Mass flow (MFC) display SP-833AHandling Company
U-Inix Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Measurement type | Measurement method | Display | Display changeover switch | Display switching | External setting signal | Low cut | Mechanical dial (CMDSET) | Command setting potentiometer (CMDSET) | Command changeover switch (COMMAND) | VOR switch | VOR IN | TO lamp | RA lamp | OV lamp | OUT2 lamp | OUT1 lamp | MFC integrated value measurement accuracy | MFC integrated value display range | MFC integrated value display offset | MFC integrated value decimal point display | MFC integrated value scaling method | MFC integrated value over display | MFC flow rate value measurement accuracy | MFC flow rate value display range | MFC flow rate value Display sampling time | MFC flow rate value lowest digit correction | MFC flow rate value Decimal point display | MFC flow value scaling method | MFC flow signal (output signal from MFC) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SP-833A |
Available upon quote |
MFC flow rate value (instantaneous) / MFC integrated value (integrated) |
A/D conversion method |
Red LED 5-digit display |
SET: Displays the flow rate set value (for COMMAND) |
Switch the display of MFC flow rate value/MFC integrated value using the ▲ key (requires setting in “Mode No. 4”) |
DC 0-5V terminal block input resistance 330KΩ |
0 to 29% of maximum analog input (can be set arbitrarily) |
10-turn mechanical dial, minimum scale value 1/50 1 turn |
Set MFC to any flow rate value |
EXT: The external set value signal becomes the flow rate set value display. |
3 positions that can be switched by pulling the knob |
VOR operation possible from outside |
“TO” lamp (red) lights up while displaying MFC integrated value |
“RA” lamp (red) lights up while displaying MFC integrated value |
“OV” lamp (red) lights up when the displayed measured value exceeds |
Lights up while alarm output OUT2 is output |
Lights up while alarm output OUT1 is output |
±0.3% (F.S.) ±1digit (23℃) for analog input |
0~99,999 |
The MFC integrated value after reset can be set arbitrarily within the range of 0 to 99999 by setting the display offset value. |
You can select from 1 to 4 digits below the decimal point. |
By mode setting, you can arbitrarily set the MFC integrated value per hour at the maximum analog input value. |
When "99999" or more is displayed, the displayed value will be automatically shifted one digit to the right (hereinafter referred to as right shift display). |
±0.3% (F.S.) ±1digit (23℃) for analog input |
0~9,999 (When the display is over, "9,999" flashes and the OV lamp lights up) |
Averages the display in about 0.5 seconds (fixed) |
Selectable from “Normal”, “0 fixed”, “0 or 5 display” |
Set at maximum display value (mode No. 1) |
MFC flow value display at maximum analog input can be set arbitrarily (0.001 ~ 9,999) |
DC 0-5V D-sub input resistance 330KΩ |