All Categories
History
Response Rate
100.0%
Response Time
40.3hours
Product
Noise blocking exchange automatic constant voltage device noise cut AVRHandling Company
Denken Seiki Research InstituteCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Rated output capacity | Rated input frequency | Input frequency tolerance | Rated input voltage | Input voltage fluctuation tolerance range | Power factor | Output frequency | Rated output voltage | Output voltage accuracy | Output voltage fine adjustment range | Output voltage strain distortion rate | Output current tolerance | efficiency | Transitional response characteristics | Insulation resistance | Exchange -powered voltage | Impulse -resistant voltage | Noise blocking characteristics | Operation peripheral temperature | Operation surroundings | Place to use | others |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Single phase 20kva |
Available upon quote |
Single phase 510va ~ 100kVA, three -phase 3kVA ~ 300kva (specified when ordering) |
50Hz dedicated or 60Hz only (specified when ordering) |
± 1Hz |
100V to 440V (specified when ordering) |
± 10% (single -phase 510va to 10KVA ± 15%) |
0.94 or more (when rated input / full load) |
Same for input |
100V to 440V (specified when ordering) |
± 1% |
Approximately ± 2.5% |
2%or less (rated input, full load) |
0 to 100% (at the load rate of 1.0), 0 to 70% (at 0.7 (delay)) |
80-93% (rated input / full resistance) |
Within 0.3 seconds (time to set a sudden change of 10%input voltage within ± 1%) |
10mΩ or more (between DC1000V circuit-housing, input-output) |
1500V50 / 60Hz 1 minute (between circuit-housing, input-output) * Rated voltage 251V or more 2000V |
1.2 / 50μs Standard shock wave 5kv1 times (JEC-0202 input and housing) |
Differential mode (normal mode) 10kHz ~ 100MHz -40db or less Common mode DC ~ 100MHz -40db or less. |
-10 ° C to 40 ℃ |
Relative humidity 10-90% (without condensation) |
Corrosive gas, remarkable conductive dustless, breathable indoor atmosphere |
Please contact us as you can also make specifications other than the above. |
|
Single phase 50kva |
Available upon quote |
Single phase 510va ~ 100kVA, three -phase 3kVA ~ 300kva (specified when ordering) |
50Hz dedicated or 60Hz only (specified when ordering) |
± 1Hz |
100V to 440V (specified when ordering) |
± 10% (single -phase 510va to 10KVA ± 15%) |
0.94 or more (when rated input / full load) |
Same for input |
100V to 440V (specified when ordering) |
± 1% |
Approximately ± 2.5% |
2%or less (rated input, full load) |
0 to 100% (at the load rate of 1.0), 0 to 70% (at 0.7 (delay)) |
80-93% (rated input / full resistance) |
Within 0.3 seconds (time to set a sudden change of 10%input voltage within ± 1%) |
10mΩ or more (between DC1000V circuit-housing, input-output) |
1500V50 / 60Hz 1 minute (between circuit-housing, input-output) * Rated voltage 251V or more 2000V |
1.2 / 50μs Standard shock wave 5kv1 times (JEC-0202 input and housing) |
Differential mode (normal mode) 10kHz ~ 100MHz -40db or less Common mode DC ~ 100MHz -40db or less. |
-10 ° C to 40 ℃ |
Relative humidity 10-90% (without condensation) |
Corrosive gas, remarkable conductive dustless, breathable indoor atmosphere |
Please contact us as you can also make specifications other than the above. |
|
Single phase 510va ~ 10kva |
Available upon quote |
Single phase 510va ~ 100kVA, three -phase 3kVA ~ 300kva (specified when ordering) |
50Hz dedicated or 60Hz only (specified when ordering) |
± 1Hz |
100V to 440V (specified when ordering) |
± 10% (single -phase 510va to 10KVA ± 15%) |
0.94 or more (when rated input / full load) |
Same for input |
100V to 440V (specified when ordering) |
± 1% |
Approximately ± 2.5% |
2%or less (rated input, full load) |
0 to 100% (at the load rate of 1.0), 0 to 70% (at 0.7 (delay)) |
80-93% (rated input / full resistance) |
Within 0.3 seconds (time to set a sudden change of 10%input voltage within ± 1%) |
10mΩ or more (between DC1000V circuit-housing, input-output) |
1500V50 / 60Hz 1 minute (between circuit-housing, input-output) * Rated voltage 251V or more 2000V |
1.2 / 50μs Standard shock wave 5kv1 times (JEC-0202 input and housing) |
Differential mode (normal mode) 10kHz ~ 100MHz -40db or less Common mode DC ~ 100MHz -40db or less. |
-10 ° C to 40 ℃ |
Relative humidity 10-90% (without condensation) |
Corrosive gas, remarkable conductive dustless, breathable indoor atmosphere |
Please contact us as you can also make specifications other than the above. |
|
Single phase 510va |
Available upon quote |
Single phase 510va ~ 100kVA, three -phase 3kVA ~ 300kva (specified when ordering) |
50Hz dedicated or 60Hz only (specified when ordering) |
± 1Hz |
100V to 440V (specified when ordering) |
± 10% (single -phase 510va to 10KVA ± 15%) |
0.94 or more (when rated input / full load) |
Same for input |
100V to 440V (specified when ordering) |
± 1% |
Approximately ± 2.5% |
2%or less (rated input, full load) |
0 to 100% (at the load rate of 1.0), 0 to 70% (at 0.7 (delay)) |
80-93% (rated input / full resistance) |
Within 0.3 seconds (time to set a sudden change of 10%input voltage within ± 1%) |
10mΩ or more (between DC1000V circuit-housing, input-output) |
1500V50 / 60Hz 1 minute (between circuit-housing, input-output) * Rated voltage 251V or more 2000V |
1.2 / 50μs Standard shock wave 5kv1 times (JEC-0202 input and housing) |
Differential mode (normal mode) 10kHz ~ 100MHz -40db or less Common mode DC ~ 100MHz -40db or less. |
-10 ° C to 40 ℃ |
Relative humidity 10-90% (without condensation) |
Corrosive gas, remarkable conductive dustless, breathable indoor atmosphere |
Please contact us as you can also make specifications other than the above. |
|
Single -phase 1KVA |
Available upon quote |
Single phase 510va ~ 100kVA, three -phase 3kVA ~ 300kva (specified when ordering) |
50Hz dedicated or 60Hz only (specified when ordering) |
± 1Hz |
100V to 440V (specified when ordering) |
± 10% (single -phase 510va to 10KVA ± 15%) |
0.94 or more (when rated input / full load) |
Same for input |
100V to 440V (specified when ordering) |
± 1% |
Approximately ± 2.5% |
2%or less (rated input, full load) |
0 to 100% (at the load rate of 1.0), 0 to 70% (at 0.7 (delay)) |
80-93% (rated input / full resistance) |
Within 0.3 seconds (time to set a sudden change of 10%input voltage within ± 1%) |
10mΩ or more (between DC1000V circuit-housing, input-output) |
1500V50 / 60Hz 1 minute (between circuit-housing, input-output) * Rated voltage 251V or more 2000V |
1.2 / 50μs Standard shock wave 5kv1 times (JEC-0202 input and housing) |
Differential mode (normal mode) 10kHz ~ 100MHz -40db or less Common mode DC ~ 100MHz -40db or less. |
-10 ° C to 40 ℃ |
Relative humidity 10-90% (without condensation) |
Corrosive gas, remarkable conductive dustless, breathable indoor atmosphere |
Please contact us as you can also make specifications other than the above. |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
40.3hrs