Hydrangea measuring device MOICO Moiko -A19Handling Company
HIRANUMACategories
Image | Part Number | Price (excluding tax) | Measurement method | Simultaneous measurement function | Title -specific control method | End point detection method | Measurement range | Display resolution ability | Background correction | Measurement accuracy | Measurement office required | Deadly cell | Electrolytes | Display method | Indicated unit | Computational function | File function | Data memory number | GLP compatible function | Manual supply and exhaust unit | Printer | External input / output | power supply | Size / weight | option |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
MOICO Moiko -A19 |
Available upon quote |
Curl Fisher Power Title Setting method |
Moisture (electricity method / capacity method) and titration, up to four types of simultaneous measurements (by optional addition unit) |
Regular current current electrolytes and intermittent electrolytes only near the end point |
Against parliamentary potential difference check method |
5μGH20-300mGH2O |
0.1μg |
Automatic correction (setting for correction is possible) |
Within 0.3 % CV (when 1mGH2O / ml water -about 1g of methanol is measured 10 times) |
Fast: 1.8MGH2O / min (30 μGH2O / Sec) Medium: 1.2MGH2O / min (20 μGH2O / Sec) Slow: 0.6MGH2O / Min (10μGH2O / Sec) |
2 -room electrolyte cell: 150ml (minimum generated liquid amount: about 100 ml) Each room electrolytic cell: 150ml (minimum generated liquid amount: about 100 ml) A small capacity per room electrolytic cell: 75 ml (minimum generated liquid amount: about 25 ml) or more. |
Ion replacement membrane (two -room electrolytic cell only) |
8.4 inch color touch panel LCD display |
μGH2O, PPM, % |
Calculation, recalculation, statistical calculation |
Measurement condition file (measurement conditional file according to the sample): 51 file sample file (reservation setting file for sampling volume): 99 File EV measurement sequence file: 51 files |
Memory of the main unit: 100 data / channel ( *) 1 Depending on the capacity of the data (such as when data for each elapsed time increases), it may not be the number of data. USB memory (256MB or more): Up to about 9,900 data |
(1) Electrode management 1. Total solution of generated solution, replacement date and replacement alarm 2. 3. Release of the opposite solution, replacement date and replacement alarm 3. 3. The exchange date of the ion exchange membrane 3. Incidental electrode exchange date (2) Measurement accuracy test (3) User management function |
Included in the configuration without drain cock |
Built-in thermal printer (roll-sensitive heat paper width 58mm) [Option] Dot impact printer PR-302B (roll normal paper width 58mm) can be connected |
[MC-3000] RS-232C: 1 port LAN for balance or HOST: 1 port USB: 1 port (for USB memory only) [TQ-3000] RS-232C: Heated vaporizational device communication 1 port 1 port |
AC100V ± 10%50 / 60Hz110va |
MC-3000: 235W x 400D x 250H (mm) Approximately 5.0kgtq-3000: 110W x 250D x 160H (mm) Approximately 2.5kgk-3000A: 100W x 165D x 175H (mm) Approximately 1.5kg Manual depletion unit: 180W x 260H (M M) Approximately 1.2kg |
・ Dot impact printer PR-302B ・ Water moisture measuring unit TQ-3000s / F / E (with Starla) ・ Capacity Hydraulic Measurement Unit TQV-3000S / E (K-3000A Starla) ・ Title Station TS-3000 ・ Starla K-3000T (for hypingization) ・ Moisture. Equipment EV-2000, lubricant water vaporization device EV-2000L, automatic additive-added hydrogen vaporization device EV-2010 ・ Automatic hydration vaporization device SE-320 ・ Automatic lubricating water moisture device LE-320 |