Flow injection analyzer (FIA) Multi-item analyzer FIA-300M-FIA-300M
Flow injection analyzer (FIA) Multi-item analyzer FIA-300M-Nittoseiko Analytech Co., Ltd

Flow injection analyzer (FIA) Multi-item analyzer FIA-300M
Nittoseiko Analytech Co., Ltd


About This Product

■Measurement items Ammonia nitrogen, nitrite nitrogen, nitrate nitrogen, phosphate phosphorus, phenols, fluorine compounds, cyanide compounds, chromium (VI) FIA-300M is a device that uses the FIA-300 series Flow Injection Analysis (FIA) method. Measurements can be made using the FIA ​​method as stipulated by JIS K0126 General Rules for Flow Analysis. The FIA ​​method is an analysis method in which a sample or reagent is introduced into the flow of the reagent or sample in a capillary tube, reaction operations are performed, and then the analytical components are detected and quantified using a detection section installed downstream. . Measurements are performed using a closed system that is less susceptible to external factors, allowing for highly accurate measurements. Additionally, since it prevents chemical substances from scattering, it is an environment-friendly and analyzer-friendly device. This device uses FIA's method to automate the analysis methods for eight items stipulated in the Fifth Total Volume Regulation, environmental standards, wastewater standards, tap water quality standards, and sewage discharge standards. Features ■High sensitivity analysis ・Pump with excellent liquid delivery stability ・Piping of constant length and constant temperature ・Since a stable baseline is obtained, small changes can be detected, and sufficient analytical sensitivity can be obtained with a small amount of sample. ■Versatility The multi-item analyzer FIA-300M can measure many analysis items with one unit. (Reaction reagents and interference filters need to be replaced.) ■Suitable for the following customers Since the frequency of analysis is low, a certain amount of samples are analyzed all at once. It is difficult to purchase a dedicated analyzer. ■Piping configuration The simple piping configuration makes it easy to check the condition of the piping and to replace it easily. ■Small sample/small reagent Compared to manual analysis, the amount of samples and reagents used for analysis can be significantly reduced. As a result, the amount of waste fluid generated after analysis can also be reduced. ■Automation By connecting the auto sample changer ASC-F50L, you can automate the measurement of 50 to 150 samples. By selecting options, it is possible to handle samples with a large amount of suspended solids (SS) or samples with high concentrations.

  • Product

    Flow injection analyzer (FIA) Multi-item analyzer FIA-300M

Share this product


50+ people viewing

Last viewed: 13 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Flow injection analyzer (FIA) Multi-item analyzer FIA-300M

Product Image Part Number Price (excluding tax) Analysis item Ammonia nitrogen Analysis item Chromium (VI) Analysis item Fluorine compounds Analysis item Nitrate nitrogen Analysis item Nitrite nitrogen Analysis item Phenols Analysis item Phosphate phosphorus Analysis item cyanide Analysis method External dimensions Heating section Liquid sending part Mass
Flow injection analyzer (FIA) Multi-item analyzer FIA-300M-Part Number-FIA-300M

FIA-300M

Available upon quote Measurement wavelength: 660 nm
Corresponding standard: JIS K 0102 42.2 Indophenol blue spectrophotometry
Measurement wavelength: 540 nm
Corresponding standard: JIS K 0102 65.2.1 Diphenylcarbazide spectrophotometry
Measurement wavelength: 620 nm
Corresponding standard: JIS K 0102 34.1 Lanthanum-Alizarin complexone spectrophotometry
Measurement wavelength: 540nm
Corresponding standard: JIS K 0102 43.2.3 Copper/cadmium column reduction - naphthylethylenediamine spectrophotometry
Measurement wavelength: 540 nm
Corresponding standard: JIS K 0102 43.1.1 Naphthylethylenediamine spectrophotometry
Measurement wavelength: 510 nm
Corresponding standard: JIS K 0102 28.1.2 4-aminoantipyrine spectrophotometry
Measurement wavelength: 880nm
Corresponding standard: JIS K 0102 46.1.1 Molybdenum blue absorption photometry
Measurement wavelength: 636 nm
Corresponding standard: JIS K 0102 38.3 4-pyridinecarboxylic acid-pyrazolone spectrophotometry
Oxidative thermal decomposition - spectrophotometric method (total nitrogen, total phosphorus)
Absorption photometry (other)
Approx. 350 (W) × 500 (D) × 470 (H) mm AC100 V 50/60 Hz Reactor method Double plunger pump
Flow rate: 0.1~1.9 mL/min
Pressure resistance: 2.94 MPa (30 kgf/cm2)
Wetted parts: PTFE, ETFE, sapphire, ruby
Approximately 22 kg