Product
Aluminum electrolytic capacitors board independent aluminum electrolytic capacitors special productsHandling Company
AisetecItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Available lipple current | Charging and discharge durability | Electrostatic capacity tolerance difference | Form of form | Guarantee life (H) | High -temperature load | High -temperature no load | Intercus of losing angle (tanδ) | Leak current | Power voltage (V.DC) | Related standards | Reliable quality | Small | Static capacity range (µF) | Used temperature range (℃) | Voltage used (V.DC) | overview |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
UW |
Available upon quote | According to the standard product rating table (105 ° C, 120Hz) | - | ± 20 % (20 ° C, 120Hz) | Special product | 1,500 | When measuring at 105 ° C for 1,500 hours (ripple current platform of the prescribed) at 20 ° C, satisfaction of the following is satisfied at 20 ° C. | 500 hours to 105 ° C. without applying the voltage at 205 ° C. When measuring after the voltage treatment (JIS C 5101-4 4.1 4.1), the following is a generic capacity change rate: Loss of the initial value of ± 15 % or less: 175 % or less of the initial standard value: Leakage current. | The value of the standard product rating table (20 ° C, 120Hz) | 0.02 cv (μA) or 5ma less than a small value (20 ° C, 5 minutes) | - | JIS C 5101-4 | - | ◎ | 210-1,150 | -10 ~+105 | 450 | 105 ° C ultra -small product | |
CU |
Available upon quote | According to the standard product rating table (105 ° C, 120Hz) | - | ± 20 % (20 ° C, 120Hz) | Special product | 2,000 | 2,000 hours at 105 ° C. When the rated voltage (the prescribed ripple current platform) is applied at 20 ° C, the following is satisfied at 20 ° C. | 500 hours to 105 ° C. without applying the voltage at 205 ° C. When measuring after the voltage treatment (JIS C 5101-4 4.1 4.1), the following is a generic capacity change rate: Loss of the initial value of ± 15 % or less: 175 % or less of the initial standard value: Leakage current. | The value of the standard product rating table (20 ° C, 120Hz) | 0.02 cv (μA) or 5ma less than a small value (20 ° C, 5 minutes) | - | JIS C 5101-4 | ◯ | - | 120-1,200 | -25 ~+105 | 400-500 | 105 ° C high ripple goods Yokonban | |
ZR |
Available upon quote | According to the standard product rating table (105 ° C, 120Hz) | - | ± 20 % (20 ° C, 120Hz) | Special product | 3,000 | 3,000 hours at 105 ° C. When the rated voltage (the prescribed ripple current platform) is applied at 20 ° C., satisfaction capacity change ratio is satisfied: Loss of the initial value of ± 20 % or less: 200 % or less of the initial standard value: | 500 hours to 105 ° C. without applying the voltage at 205 ° C. When measuring after the voltage treatment (JIS C 5101-4 4.1 4.1), the following is a generic capacity change rate: Loss of the initial value of ± 15 % or less: 175 % or less of the initial standard value: Leakage current. | The value of the standard product rating table (20 ° C, 120Hz) | 0.02 cv (μA) or 3ma less than (20 ° C, 5 minutes) | - | JIS C 5101-4 | ◯ | ◯ | 150-680 | -40 ~+105 | 400, 450 | 105 ℃ high ripple product | |
Zlr |
Available upon quote | According to the standard product rating table (105 ° C, 120Hz) | - | ± 20 % (20 ° C, 120Hz) | Special product | 3,000 | 3,000 hours at 105 ° C. When the rated voltage (the prescribed ripple current platform) is applied at 20 ° C., satisfaction capacity change ratio is satisfied: Loss of the initial value of ± 20 % or less: 200 % or less of the initial standard value: | 500 hours to 105 ° C. without applying the voltage at 205 ° C. When measuring after the voltage treatment (JIS C 5101-4 4.1 4.1), the following is a generic capacity change rate: Loss of the initial value of ± 15 % or less: 175 % or less of the initial standard value: Leakage current. | The value of the standard product rating table (20 ° C, 120Hz) | 0.02 cv (μA) or 3ma less than (20 ° C, 5 minutes) | - | JIS C 5101-4 | ◯ | ◯ | 68-680 | -40 ~+105 | 400, 450 | 105 ℃ high ripple product | |
DH |
Available upon quote | According to the standard product rating table (105 ° C, 120Hz) | Places of peripheral temperature 40 ° C, charging electric potential difference (ΔV) = 150V, charging and discharged frequency 6Hz, after applying the number of charging electricity, satisfaction of the following is a static capacity change rate of ± 20 % or less in the initial value of 200 % or less: Leakage of 200 % of the initial standard value: Learn below the initial standard value. | ± 20 % (20 ° C, 120Hz) | Special product | 3,000 | 3,000 hours at 105 ° C. When the rated voltage (the prescribed ripple current platform) is applied at 20 ° C., satisfaction capacity change ratio is satisfied: Loss of the initial value of ± 20 % or less: 200 % or less of the initial standard value: | 500 hours to 105 ° C, and after leaving the rating without applying the rating, after the voltage treatment (JIS C 5101-4 4.1 4.1) at 20 ° C. | The value of the standard product rating table (20 ° C, 120Hz) | 0.02 cv (μA) or 3ma less than (20 ° C, 5 minutes) | - | JIS C 5101-4 | ◎ | - | 82-680 | -25 ~+105 | 400, 450 | Charging and discharge -compatible products | |
HW |
Available upon quote | - | After applying rated voltage at room temperature, 5,000 times of charging and discharge with 1 Ω discharge with discharge of 5,000 times, then satisfied with the following, generating capacity change rates: Interlosal of a loss angle within ± 15 % of the initial value: 150 % or less of the initial standard value: 150 % or less of the initial standard value. | -10- + 20 % (20 ° C, 120Hz) | Special product | - | - | - | The value of the standard product rating table (20 ° C, 120Hz) | C ≦ 3,000: 0.02 cv (μA) or 3ma less than small (20 ° C, 5 minutes) C> 3,000: 1 × C (μA) (20 ° C, 5 minutes) | 350-470 | EIAJ-RC2365, JIS C 5101-4 | - | ◎ | 320-3,800 | -20 ~+55 | 330-450 | Large -capacity small -caps for flashing, strobe | |
HS |
Available upon quote | - | After applying rated voltage at room temperature, 5,000 times of charging and discharge with 1 Ω discharge with discharge of 5,000 times, then satisfied with the following, generating capacity change rates: Interlosal of a loss angle within ± 15 % of the initial value: 150 % or less of the initial standard value: 150 % or less of the initial standard value. | -10- + 20 % (20 ° C, 120Hz) | Special product | - | - | - | The value of the standard product rating table (20 ° C, 120Hz) | C ≦ 3,000: 0.02 cv (μA) or 3ma (0 ° C, 5 minutes) C> 3,000: 1 × c (μA) (20 ° C, 5 minutes) | 350-470 | EIAJ-RC2365, JIS C 5101-4 | - | ◯ | 300-3,100 | -20 ~+55 | 330-450 | Large -capacity product standard product for flashing, strobe |
Click on the part number for more information about each product