All Categories
History
Response Rate
100.0%
Response Time
37.1hours
Product
Screw terminal -shaped aluminum electrolytic capacitors standard productsHandling Company
AisetecCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | type | overview | Guarantee life (H) | Used temperature range (℃) | Standard goods | Voltage used (V.DC) | Static capacity range (µF) | Electrostatic capacity tolerance difference | Leak current | Intercus of losing angle (tanδ) | Available lipple current | High -temperature load | High -temperature no load | Related standards |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Vf |
Available upon quote |
Standard goods |
Standard goods |
2,000 |
-40 (-25) to+85 |
◯ |
6.3-650 |
560-680,000 |
± 20 % (20 ° C, 120Hz) |
0.01CV (μA) or 5ma less than a small value (20 ° C, 5 minutes) |
The value of the standard product rating table (20 ° C, 120Hz) |
According to the standard product rating table (85 ° C, 120Hz) |
2,000 hours at 85 ° C. When the rated voltage (the prescribed ripple current topic) is applied at 20 ° C, the following is satisfied at 20 ° C. |
500 hours at 85 ° C, left voltage without applying the voltage, and when measured after voltage treatment (JIS C 5101-4 4.1) at 20 ° C. |
JIS C 5101-4 |
![]() |
VG |
Available upon quote |
Standard goods |
105 ℃ Standard |
2,000 |
-40 ~+105 |
◯ |
25-500 |
560-330,000 |
± 20 % (20 ° C, 120Hz) |
0.01CV (μA) or 5mA or less (20 ° C, 5 minutes) |
The value of the standard product rating table (20 ° C, 120Hz) |
According to the standard product rating table (105 ° C, 120Hz) |
2,000 hours at 105 ° C. When the rated voltage (the prescribed ripple current topic) is applied at 20 ° C, the following is satisfied at 20 ° C. |
500 hours to 105 ° C. without applying the voltage at 205 ° C. When measuring after the voltage treatment (JIS C 5101-4 4.1 4.1), the following is a generic capacity change rate: Loss of the initial value of ± 15 % or less: 175 % or less of the initial standard value: Leakage current. |
JIS C 5101-4 |
![]() |
VFL |
Available upon quote |
Standard goods |
5kH standard product long life |
5,000 |
-40 ~+85 |
◯ |
350-600 |
470-27,000 |
± 20 % (20 ° C, 120Hz) |
0.01CV (μA) or 5mA or less (20 ° C, 5 minutes) |
The value of the standard product rating table (20 ° C, 120Hz) |
According to the standard product rating table (85 ° C, 120Hz) |
5,000 hours at 85 ° C. When the rated voltage (the prescribed ripple current topic) is applied at 20 ° C, the following is satisfied at 20 ° C. |
500 hours at 85 ° C, left voltage without applying the voltage, and when measured after voltage treatment (JIS C 5101-4 4.1) at 20 ° C. |
JIS C 5101-4 |
![]() |
VGL |
Available upon quote |
Standard goods |
105 ° C 5kH standard product long life |
5,000 |
-40 ~+105 |
◯ |
350-500 |
560-27,000 |
± 20 % (20 ° C, 120Hz) |
0.01CV (μA) or 5mA or less (20 ° C, 5 minutes) |
The value of the standard product rating table (20 ° C, 120Hz) |
According to the standard product rating table (105 ° C, 120Hz) |
5,000 hours at 105 ° C. When the rated voltage (the prescribed ripple current platform) is applied at 20 ° C., satisfaction capacity change rates of ± 15 % of the initial value are satisfied: Leakage of the initial standard value 175 % or less. |
500 hours to 105 ° C. without applying the voltage at 205 ° C. When measuring after the voltage treatment (JIS C 5101-4 4.1 4.1), the following is a generic capacity change rate: Loss of the initial value of ± 15 % or less: 175 % or less of the initial standard value: Leakage current. |
JIS C 5101-4 |
![]() |
Vfh |
Available upon quote |
Standard goods |
Long life |
20,000 |
-40 ~+85 |
◯ |
350-500 |
560-27,000 |
± 20 % (20 ° C, 120Hz) |
0.01CV (μA) or 5ma less than a small value (20 ° C, 5 minutes) |
(The value of the standard product rating table)) |
According to the standard product rating table (85 ° C, 120Hz) |
After applying the rated voltage (the prescribed ripple current platform) at 85 ° C for 20,000 hours (the prescribed ripple current platform), satisfying the following at 20 ° C. |
500 hours at 85 ° C, left voltage without applying the voltage, and when measured after voltage treatment (JIS C 5101-4 4.1) at 20 ° C. |
JIS C 5101-4 |
Click on the part number for more information about each product