Design sound material test kit to build sound-Hottinger Brüel & Kjær

4206 | Design sound material test kit to build sound
Hottinger Brüel & Kjær


Price (excluding tax)

Estimate Required


Model Description

4206 type impedance pipe kit (50Hz to 6.4kHz) ■ configuration ・ Pipe with an inner diameter of 100 mm (tube) ・ Inner diameter 29 mm tube (thin tube) ・ Sample holder (inner diameter 29 mm and 100 mm) ・ Extension tube (inner diameter 29 mm and 100 mm) ■ Two types of tube configurations can be assembled ・ Thick tube setup for parameter measurement of frequency range from 50 Hz to 1.6 kHz ・ Fine tube setup for parameter measurement of frequency range from 500 Hz to 6.4 kHz The thick pipe has a loud speaker on one end. In addition, a frequency load unit is attached, and the load type can be selected from the following three. ・ High pass: For high frequency frequency measurement due to thin tube ・ Linear: For measurement by thick tube ・ Low pass: High accuracy in the frequency area lower than 100 Hz In the thick tube setup, a sample holder for thick pipes is attached directly to the opening of the thick tube. There are three couplers in the tube to flash mounts inside the tube. The flash mount combines the microphone and the sound field in the jurisdiction to prevent the pressure leak that causes a measurement error. In the fine tube setup, the thin tube (with speaker) is attached to the opening of the thick tube, and a thin tube sample holder is attached to the fine tube. By attaching one or two extension pipes, and changing the position of the slide piston of the sample holder, you can change the effective length in each setting. The interior of the pipe is attached to the 4206 type, and is performed at the 4187 type 1/4 inch condominium samicrophone, which is specially designed to exclude sound pressure leaks at high frequencies. ■ Applications The 4206 and 4206A type can be used to measure the sound characteristics of a small test sample, including composite materials (eg, ceiling tiles) and implicit materials (eg, cracked acoustic tiles). The piston back plate attaches a test sample inside the sample holder, but you can pull it out and provide an air layer behind the test sample. As a result, for example, you can simulate the hanging ceiling. In addition, the 4206 type can be placed vertically to measure the arrangement sample that must be horizontally.


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

Assembly setup TL tube length

Assembly setup length

Assembly setup overall height

Frequency range

Inner diameter of extension pipe/maximum sample length (mm) (in)

Measured pipe inner diameter/maximum sample length (mm) (in)

Overall width of the assembly setup

Sample holder inner diameter/maximum sample length (mm) (in)

TL sample holder inner diameter/maximum sample length (mm) (in)

TL tube inner diameter/maximum sample length (mm) (in)

Zero sound absorption (calculated with 1/3 octava band)

See all 3 models in list
  • Part Number

    4206




*Please note that we may not be able to accommodate sample requests.

Design sound material test kit to build sound 4206's performance table

Items marked with have different values ​​depending on the model number.

Product Image Price (excluding tax) Assembly setup TL tube length Assembly setup length Assembly setup overall height Frequency range Inner diameter of extension pipe/maximum sample length (mm) (in) Measured pipe inner diameter/maximum sample length (mm) (in) Overall width of the assembly setup Sample holder inner diameter/maximum sample length (mm) (in) TL sample holder inner diameter/maximum sample length (mm) (in) TL tube inner diameter/maximum sample length (mm) (in) Zero sound absorption (calculated with 1/3 octava band)
Design sound material test kit to build sound-Part Number-4206 Available upon quote Taipei: 1170 mm (45.6 ″), thin tube: 1080 mm (42.1 ") Tense tube: 700 mm (27.7 ″), thin tube: 850 mm (33.6 ") 240 mm (9.5 ") Taipei: 50 Hz ~ 1.6 kHz, fine tube: 500 Hz ~ 6.4 kHz Large: 100 (3.9) /200 (7.9), small: 29 (1.1) /200 (7.9) Taipei: 100 (3.9) /440 (17.4), thin tube: 29 (1.1) /200 (7.9) 140 mm (5.5 ") Large: 100 (3.9) /200 (7.9), small: 29 (1.1) /200 (7.9) Large: 100 (3.9) /135 (5.3), small: 29 (1.1) /110 (4.3) Large: 100 (3.9) /260 (10.2), small: 29 (1.1) /190 (7.4) 50 Hz ~ 4 kHz: <4%, 5 kHz ~ 6.3 kHz: <10%

There are 3 models for this product.

Other products of Hottinger Brüel & Kjær


View more products of Hottinger Brüel & Kjær

About Company Handling This Product