Price (excluding tax)
Estimate Required
Model Description
Unlike conventional contact points, it is an analog remote sensor that can output a continuous signal.
The output signal can be connected to a computer or recorder by 4 to 20 ma/DC.
There are two types: "FXL type" with general -purpose drip -proof specifications and "FXD type" with pressure -resistant explosion -proof structure.
There are other magnetic distortion sensors that respond to the linear, so please contact us.
Model Filter
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Column diameter
50A (ø60.5) | MC-50
25A (ø34) | MC-25
Material
SUS304, 316, 316L, PVC, P.P, etc. | MC-50
SUS304, 316, 316L, P.P | MC-25
pressure
-0.1 ~ 5.0MPa | MC-50
-0.1 ~ 3.0MPa | MC-25
specific gravity
0.6 or higher | MC-50
0.8 or higher | MC-25
temperature
-50-320 ° C | MC-50
-50-320 ° C | MC-25
viscosity
10p or less | MC-50
4p or less | MC-25
Contact format
Self -holding type
Dry contact | SC-K3 (drip-proof type)
Self -holding type
Dry contact | SC-MS (pressure-resistant explosion-proof EXDIICT6)
Interconductible voltage
AC1800V/1S (1MA) | SC-K3 (drip-proof type)
AC1800V/1S (1MA) | SC-MS (pressure-resistant explosion-proof EXDIICT6)
Maximum opening and closing capacity
AC 50VA
DC 50W | SC-K3 (drip-proof type)
AC 50VA
DC 50W | SC-MS (pressure-resistant explosion-proof EXDIICT6)
Maximum opening and closing current
AC/DC 0.5A | SC-K3 (drip-proof type)
AC/DC 0.5A | SC-MS (pressure-resistant explosion-proof EXDIICT6)
Maximum opening and closing voltage
AC/DC 220V | SC-K3 (drip-proof type)
AC/DC 220V | SC-MS (pressure-resistant explosion-proof EXDIICT6)
structure
Drip -proof | SC-K3 (drip-proof type)
Poltolic -resistant explosionproof
(EXD IIC T6) | SC-MS (pressure-resistant explosion-proof EXDIICT6)
Drip -proof type (IP55)
Poltolic pressure explosion (EXD IIB T4) | FXD type (pressure -proof EXD II BT4)
Measurement range
0 to 5500 mm
0 to 4000 mm | FXD type (pressure -proof EXD II BT4)
Operating power
AC/DC 20-250V
AC/DC 20-250V | FXD type (pressure -proof EXD II BT4)
Output signal
4-20mA/DC
4-20mA/DC | FXD type (pressure -proof EXD II BT4)
input signal
4 lines (including power supply)
4 lines | FXD type (pressure -proof EXD II BT4)
See all 12 models in list
Part Number
FXL type (drip -proof IP55)