Accessories
Compatible motor
Control circuit power consumption
Current limit value (during home return operation)
External speed command coefficient
Magnetic pole sensor
Mass
Overload measurement current
PWM frequency
Power supply voltage
Protection function: Sensor abnormality
Protection function: fuse protection
Protection function: motor restraint
Protection function: overcurrent
Protection function: overload
Protection function: power supply voltage drop
Signal input
Signal output
Soft start setting
Speed setting (rotation speed setting)
Speed variable range
Storage environment
Usage environment
Part Number
TCP-S27A-22AHandling Company
TSUKASA ELECTRIC CO.,LTDCategories
Image | Price (excluding tax) | Accessories | Compatible motor | Control circuit power consumption | Current limit value (during home return operation) | External speed command coefficient | Magnetic pole sensor | Mass | Overload measurement current | PWM frequency | Power supply voltage | Protection function: Sensor abnormality | Protection function: fuse protection | Protection function: motor restraint | Protection function: overcurrent | Protection function: overload | Protection function: power supply voltage drop | Signal input | Signal output | Soft start setting | Speed setting (rotation speed setting) | Speed variable range | Storage environment | Usage environment |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Motor connection cable (50cm) x 1, power/control signal input/output cable (50cm) x 1 | TG-22A | 1W or less | 2.2A | 1,200rpm/V±5% | Hall IC (square wave output) | Approx. 30g (body only) | 285mA or more | Approximately 20.0KHz | DC24V±10% or less | Detects an error code in the sensor signal and shuts off the output (maintains the state), resets by turning the start input “open” and turning the power back on. | Detects abnormal power supply current and shuts off the circuit. F1 (5A chip fuse) | Detects motor restraint and shuts off the output (state maintained), detects a stop of 2 seconds or more when the motor current is flowing at 0.2 A or more when the speed command value is 250 rpm or more, determines the motor to be restrained, and starts input “open” And reset by turning on the power again | Detects abnormal motor current and cuts off output (automatic recovery) | If a current exceeding the rated output current flows continuously, the output is cut off (state maintained) and reset by turning the start input “open” and turning the power on again. | Detects a drop in power supply voltage and cuts off the output (automatic recovery) | Start input, rotation direction switching input, brake selection input, speed switching input, external speed command input | Rotation synchronization signal output, alarm output | Maximum 1.67 seconds/1,000rpm can be set with RV3 / Operates at startup and speed command increase (D1 flashes during operation) | Driver internal settings: 2 systems RV1 and RV2 (switchable by speed switching input), external speed command input: 1 system | 200~4,900rpm | -10~60℃, 85%RH or less (no condensation) | 0~40℃, 85%RH or less (no condensation), used in an atmosphere with thermal convection |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.