All Categories
History
Price (excluding tax)
Response Rate
100.0%
Response Time
29.4hours
Relatively Fast Response
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Amount of cooling water used
Automatic control
Cooling method
External dimensions/weight control section
External dimensions/weight heating part
General purpose input/output
High frequency output
Manual control Constant output control
Manual control Constant temperature control
Operating ambient temperature
Oscillation frequency
Power supply voltage
Remote control
Resonance method
Safety equipment
Storage ambient temperature
Switching method
Temperature input
Usage environment
Part Number
MU-αⅣHandling Company
SK Medical Electronics Co., Ltd.Categories
Image | Price (excluding tax) | Amount of cooling water used | Automatic control | Cooling method | External dimensions/weight control section | External dimensions/weight heating part | General purpose input/output | High frequency output | Manual control Constant output control | Manual control Constant temperature control | Operating ambient temperature | Oscillation frequency | Power supply voltage | Remote control | Resonance method | Safety equipment | Storage ambient temperature | Switching method | Temperature input | Usage environment |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Approx. 3.5L/min (at water pressure 0.25MPa) | Program output/temperature control (number of programs: 10, number of steps: 15/1 program) | Water cooling type (heating coil, resonance capacitor, high frequency transformer, switching element) ・Cooling fan | 300×300×280mm (12kg) | 400×500×320mm (31kg) | Input: 8 points (1 point is only for emergency stop) Output: 8 points (DC24V, 20mA) | Maximum (regular use) 6kW (6kW) | Output adjustment by volume (0~100%, 0.1% increments) | Temperature adjustment by volume (room temperature to maximum value, 1℃ increments) | 5~40℃ (20~85%RH) No condensation | 350~450kHz (depending on heating coil specifications) | Single phase AC200V±10%, 50/60Hz±5% | Control by external signal (4~20mA) | LC series resonance | Earth leakage breaker, fast-acting fuse, cooling water flow rate, temperature, water leakage detection, resonance monitoring, sensor abnormality (disconnection detection), upper/lower temperature limits, overcurrent, emergency stop, etc. | -10~60℃ (85%RH or less) No condensation or freezing | Power MOS-FET full bridge inverter | Thermocouple (K,J,E,W,N,R,S,B,T) Radiation thermometer (220-2,000, 300-2,000, 600-2,000, 600-3,000℃) | Indoor use, altitude below 2,000m, pollution level 2 |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
29.4hrs