All Categories
History
Price (excluding tax)
■Summary The single point load cell PW15B is made of stainless steel and can be applied to a wide range of ambient conditions. Various explosion-proof models and balanced output options are available, making it ideal for designing and manufacturing platform scales with parallel connections. ■Main functions ・Minimum verification interval for multi-range applications ・Explosion-proof specification also available ・Ideal for parallel connection due to adjusted output (optional)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Accuracy grade/minimum verification scale (Y)
Allowable load EU
Allowable temperature range Btu
Breaking load Ed
Bridge applied voltage range BU
Deflection amount at maximum capacity load (approximate) Snom
Eccentricity (off-center) error
Hysteresis error dhy
Input resistance RLC
Insulation resistance Ris at 100VDC
Limit load EL
Mass (approximate) m
Maximum applied voltage
Maximum capacity Emax
Maximum load cell division number nLC
Maximum loading surface
Minimum load output return MDLOR
Minimum verification scale vmin
Nonlinearity dlin
Output resistance R0
Ratio of minimum verification scale Y
Reference bridge applied voltage Uref
Relative allowable dynamic load Fsrel
Sensitivity Cn
Static critical lateral stress Elq
Storage temperature range Btl
Temperature compensation range BT
Temperature effect on sensitivity
Temperature effect on zero point TC0
Zero point
Part Number
PW15BProduct
Single point load cell SP4M/PW15Handling Company
Hottinger Brüel & KjærCategories
Image | Price (excluding tax) | Accuracy grade/minimum verification scale (Y) | Allowable load EU | Allowable temperature range Btu | Breaking load Ed | Bridge applied voltage range BU | Deflection amount at maximum capacity load (approximate) Snom | Eccentricity (off-center) error | Hysteresis error dhy | Input resistance RLC | Insulation resistance Ris at 100VDC | Limit load EL | Mass (approximate) m | Maximum applied voltage | Maximum capacity Emax | Maximum load cell division number nLC | Maximum loading surface | Minimum load output return MDLOR | Minimum verification scale vmin | Nonlinearity dlin | Output resistance R0 | Ratio of minimum verification scale Y | Reference bridge applied voltage Uref | Relative allowable dynamic load Fsrel | Sensitivity Cn | Static critical lateral stress Elq | Storage temperature range Btl | Temperature compensation range BT | Temperature effect on sensitivity | Temperature effect on zero point TC0 | Zero point |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | C3 Multi-Range (MR) | Up to 100mm away from center: 150 (% of Emax) | -10~+50℃ | Position 20mm away from center: 300 (% of Emax) | 1~12V | 0.17mm~0.21mm | ≦233ppm (according to OIML R76) | ±0.0166 (% of Cn) (Typical value for hysteresis error. These combined values meet the cumulative error requirements specified in OIML R60) | 300~500Ω | >1GΩ | Up to 160mm away from center: 150 (% of Emax) | 1kg | 15V | 7.5~200kg | 3,000 | 500×400mm | ±0.0166 (% of Cn) | 0.5~20g | ±0.0166 (% of Cn) (Typical value for nonlinearity. These combined values meet the cumulative error requirements specified in OIML R60) | 300~500Ω (Option 6: 359±0.2) | 10,000~15,000 | 5V | Up to 20mm away from center: 70 (% of Emax) | 2.0±0.2mV/V (Option 6: 2.0mV/V±0.1%) | 300 (% of Emax) | -25~+70℃ | -10~+40℃ | ±0.0093~0.0140 (Cn%/10K) | 0±0.1mV/V |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.