Accuracy class
Allowable temperature range Btu
Breaking load Ed
Bridge applied voltage range BU
Deflection amount sexz
Deflection amount snom
Eccentricity (off-center) error
Error relative to zero point
Hysteresis error dhy
Input resistance RLC
Insulation resistance Ris at 100VDC
Limit load EL
Mass (approximate) m
Maximum applied voltage
Maximum capacity Emax
Maximum load cell division number nLC
Maximum loading surface
Minimum load output return MDLOR
Minimum verification scale vmin
Nonlinearity dlin
Output resistance R0
Protection class
Ratio of minimum verification scale Y
Reference bridge applied voltage Uref
Sensitivity Cn
Static critical lateral stress Elq
Storage temperature range Btl
Temperature compensation range BT
Temperature effect on sensitivity per 10K TKc
Temperature effect on zero point TK0
Part Number
PW29PProduct
Single point load cell PW29Handling Company
Hottinger Brüel & KjærCategories
Image | Price (excluding tax) | Accuracy class | Allowable temperature range Btu | Breaking load Ed | Bridge applied voltage range BU | Deflection amount sexz | Deflection amount snom | Eccentricity (off-center) error | Error relative to zero point | Hysteresis error dhy | Input resistance RLC | Insulation resistance Ris at 100VDC | Limit load EL | Mass (approximate) m | Maximum applied voltage | Maximum capacity Emax | Maximum load cell division number nLC | Maximum loading surface | Minimum load output return MDLOR | Minimum verification scale vmin | Nonlinearity dlin | Output resistance R0 | Protection class | Ratio of minimum verification scale Y | Reference bridge applied voltage Uref | Sensitivity Cn | Static critical lateral stress Elq | Storage temperature range Btl | Temperature compensation range BT | Temperature effect on sensitivity per 10K TKc | Temperature effect on zero point TK0 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | C3 Multi-Range (MR) | -10~+50℃ | 300 (% of Emax) | 1~12V | <0.1~0.3mm (at 1/3 Emax and 283mm away from the center) | <0.2~0.3mm (When the load is applied at Emax at the center of gravity of the load cell) | ≦233ppm (according to OIML R76) | ±0.1mV/V | ±0.0166 (% of Cn) (Typical value for hysteresis error. These combined values meet the cumulative error requirements specified in OIML R60) | 300~500W | >2GW | Up to 100mm away from center: 150 | 6.3kg | 15V | 100/250/500/750/1,000kg | 3,000 | 800×800mm | ±0.0166 (% of Cn) | 10/20/50/100g | ±0.0166 (% of Cn) (Typical value for nonlinearity. These combined values meet the cumulative error requirements specified in OIML R60) | 300~500W | IP68 (load test conditions: 100 hours immersion in a water tank at a depth of 1 m), IP69K (high pressure water, steam jet cleaning) (based on EN 60529 (IEC 529)) | 7,500/10,000/12,500 | 5V | 2.0±0.2mV/V | 300 (% of Emax) | -25~+70℃ | -10~+40℃ | ±0.0112/0.0140/0.0186 (%Cn/10K) |
Reviews shown here are reviews of companies.