All Categories
History
Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Accuracy class
Allowable dynamic load
Allowable temperature range Btu
Breaking load
Bridge applied voltage range BU
Deflection amount at maximum capacity load (approximate) snom
Eccentricity (off-center) error
Hysteresis error dhy
Input resistance RLC
Insulation resistance Ris at 100VDC
Limit load (20mm away from center) EL
Maximum applied voltage
Maximum capacity Emax
Maximum load cell division number nLC
Maximum loading surface
Minimum load output return MDLOR
Minimum verification scale vmin
Natural frequency (approximate)
Nonlinearity dlin
Output resistance R0
Permissible overload (up to 120mm away from center)
Ratio of minimum verification scale Y
Reference bridge applied voltage Uref
Sensitivity Cn
Static critical lateral stress Elq
Storage temperature range Btl
Temperature compensation range BT
Temperature effect on sensitivity TKc
Temperature effect on zero point TK0
Zero point
Part Number
PW25PProduct
Single point load cell PW25Handling Company
Hottinger Brüel & KjærCategories
Image | Price (excluding tax) | Accuracy class | Allowable dynamic load | Allowable temperature range Btu | Breaking load | Bridge applied voltage range BU | Deflection amount at maximum capacity load (approximate) snom | Eccentricity (off-center) error | Hysteresis error dhy | Input resistance RLC | Insulation resistance Ris at 100VDC | Limit load (20mm away from center) EL | Maximum applied voltage | Maximum capacity Emax | Maximum load cell division number nLC | Maximum loading surface | Minimum load output return MDLOR | Minimum verification scale vmin | Natural frequency (approximate) | Nonlinearity dlin | Output resistance R0 | Permissible overload (up to 120mm away from center) | Ratio of minimum verification scale Y | Reference bridge applied voltage Uref | Sensitivity Cn | Static critical lateral stress Elq | Storage temperature range Btl | Temperature compensation range BT | Temperature effect on sensitivity TKc | Temperature effect on zero point TK0 | Zero point |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | C3MR | Maximum 50mm away from center Frb: 70 | -10~+50℃ | Ed: >1,500 (% of Emax) | 1~12V | 0.19/0.18mm (When the load is applied at Emax at the center of gravity of the load cell) | ≦233ppm | ±0.0166 (% of Cn) (Typical value for hysteresis error. These combined values meet the cumulative error requirements specified in OIML R60) | 300~500Ω | >1GΩ | 1,000 | 15V | 10/20kg | 3,000 | 400×400mm | ±0.0166 (% of Cn) | 1/2g | 210/315Hz | ±0.0166 (% of Cn) (Typical value for nonlinearity. These combined values meet the cumulative error requirements specified in OIML R60) | 300~500Ω | 150 (% of Emax) | 10,000 | 5V | 2.0±0.2mV/V | 200 (% of Emax) | -25~+85℃ | -10~+40℃ | ±0.0140 (% of Cn/10K) | 0±0.1mV/V |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.