Stopped flow rapid scan spectrometerHandling Company
Unisoku Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Light source section Light intensity adjustment | Light source part lamp house | Light source lamp | Multi-channel photometry section Reverse line dispersion | Multi-channel photometry section scanning speed | Multi-channel photometry section Scanning count | Multi-channel photometry section brightness | Multi-channel photometry section Compatible measurement methods | Multi-channel photometry section Simultaneous photometry wavelength range | Multi-channel photometry section Spectroscopic element | Multi-channel photometry section spectrometer | Multi-channel photometry section entrance slit | Multi-channel photometry section Photodetection element | Multi-channel photometry section Secondary light cut | Photomal time-varying photometry section Reverse linear dispersion | Photomaru time-varying photometry section brightness | Photomal time-varying photometry section Spectroscopic element | Photomal time-varying photometry section spectrometer | Photomaru time-varying photometry section entrance slit | Photomal time-varying photometry section photodetection element | Photomal time-varying photometry section sampling time | Photomaru time-varying photometry section secondary light cut | Stopped flow mixing device Observation cell | Stopped Flow Mixer Temperature Range | Stopped flow mixing device Mixing ratio | Stopped flow mixing device Mixing dead time | Stopped flow mixing device method | Stopped flow mixing device mixer | Stopped flow mixing device Sample amount | Stopped flow mixing device cock |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
RSP-2000 |
Available upon quote |
With shutter, aperture function, and filter insertion space |
Natural air cooling type |
High stability 150W Xe arc lamp |
22nm/mm |
1ms~10s/scan |
Optional if less than 8,000 times |
F/2.9 |
Absorption time course spectrum measurement |
560nm or more *Please specify the center wavelength when ordering |
Concave blazed holographic grating |
Our polychromator PK120 |
0.05mm, 0.1mm, 0.2mm |
Photodiode array 512ch |
By internal dedicated filter |
8.5nm/mm |
F/3.5 |
Planar diffraction grating (using Czerny-Turner optical arrangement) |
Our monochromator MF-200 type |
0.1mm, 0.2mm, 0.5mm |
Hamamatsu Photonics photomultiplier tube (Photomul) R2949 |
10μs~600msec |
None |
For absorption measurement 10mm |
10℃~50℃ |
1:1 (optional up to 1:9) |
3ms or less (for 10mm absorption cell) |
Piston drive front stop system |
Double 2JET |
75μl~250μl/shot |
Ceramic/Teflon automatic three-way cock |