Product
Vibration alarm VA -300Handling Company
SortecItems marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Alarm mode | Alarm reset | Calibration signal | Connection load resistance | Detection method | Digital display | Digital display cycle | External dimensions | Frequency range | Indicating method | Measurement display mode | Measurement range (High) | Measurement range (LOW) | Mounting hole dimensions | Power -on -delay | Signal output | Smoothing constant | Supply voltage | Temperature and humidity range | Terminal stand screw | Warning delay time | Warning relay contact | Warning setting range | weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VA-300A |
Available upon quote | Alarm and trip two -stage alarm | The alarm display LED lamp is canceled by the reset button, the relay output is automatic reset. | Press the [FS] button to display the maximum value 20Hz | 300Ω or less | Effective value | 31/2 digits, red LED, character height 14mm | 1 time/second | 96 x 96 x 117 (D) mm | 10-8000Hz | One strikeout | Acceleration type | 1-199.9m/S2 | 0.1-19.99m/S2 | 92 × 92 (0 ~+0.8) mm | Operation 30 seconds after the power is turned on | Red LED lamp lighting when alarm occurs, yellow LED lamp lighting, trip occurs | About 5 seconds | Acout2vrms (maximum instruction) DCOUT2V (maximum instruction) | 0-45 ° C, 95 % RH or less (main unit only) (only for the main body) -10 to 60 ° C, 95 % RH or less (main body only) | 3.5mm | Alarm [Can be set in 2-30 seconds, 2 seconds step] Trip [Output about 2 seconds later after alarm alarm] | Trans -focusing point each route, contact capacity is a resistance load, DC24V5AAC100V5A | From 1/20 of the maximum value of each measurement range to the maximum measurement limit | 400g | |
VA-300V |
Available upon quote | Alarm and trip two -stage alarm | The alarm display LED lamp is canceled by the reset button, the relay output is automatic reset. | Press the [FS] button to display the maximum value 20Hz | 300Ω or less | Effective value | 31/2 digits, red LED, character height 14mm | 1 time/second | 96 x 96 x 117 (D) mm | 10-1000Hz | Effective value | Speed type | 1-199.9mm/s | 0.1-19.99mm/s | 92 × 92 (0 ~+0.8) mm | Operation 30 seconds after the power is turned on | Red LED lamp lighting when alarm occurs, yellow LED lamp lighting, trip occurs | About 5 seconds | Acout2vrms (maximum instruction) DCOUT2V (maximum instruction) | 0-45 ° C, 95 % RH or less (main unit only) (only for the main body) -10 to 60 ° C, 95 % RH or less (main body only) | 3.5mm | Alarm [Can be set in 2-30 seconds, 2 seconds step] Trip [Output about 2 seconds later after alarm alarm] | Trans -focusing point each route, contact capacity is a resistance load, DC24V5AAC100V5A | From 1/20 of the maximum value of each measurement range to the maximum measurement limit | 400g | |
VA-300D |
Available upon quote | Alarm and trip two -stage alarm | The alarm display LED lamp is canceled by the reset button, the relay output is automatic reset. | Press the [FS] button to display the maximum value 20Hz | 300Ω or less | Effective value | 31/2 digits, red LED, character height 14mm | 1 time/second | 96 x 96 x 117 (D) mm | 10-1000Hz | Amenity | Displaced type | 10-1999 μm | 1.0-199.9μm | 92 × 92 (0 ~+0.8) mm | Operation 30 seconds after the power is turned on | Red LED lamp lighting when alarm occurs, yellow LED lamp lighting, trip occurs | About 5 seconds | Acout2vrms (maximum instruction) DCOUT2V (maximum instruction) | 0-45 ° C, 95 % RH or less (main unit only) (only for the main body) -10 to 60 ° C, 95 % RH or less (main body only) | 3.5mm | Alarm [Can be set in 2-30 seconds, 2 seconds step] Trip [Output about 2 seconds later after alarm alarm] | Trans -focusing point each route, contact capacity is a resistance load, DC24V5AAC100V5A | From 1/20 of the maximum value of each measurement range to the maximum measurement limit | 400g |