Multi-scanning scan laser scanning road surface freezing inspection inspector OPR-1500 series (laser scanning road surface information sensor)Handling Company
Takuwa| Image | Part Number | Price (excluding tax) | Measured distance | Measurement method | Measurement range Road Area Snow Depth | Measurement range road surface temperature | Measurement accuracy Road Area Snow depth | Measurement accuracy road surface temperature | Measurement interval surface surface snow depth, road surface status | Measurement interval surface temperature, temperature | Snowfish surface snow depth depth | Resolution Noh road surface temperature | Laser scanning angle | Laser safety standard | Installation angle | Output signal | Laser marker | option | Operation voltage power supply | power consumption | Operating temperature | Protection grade | Materials / processing | Dimensions / mass | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
                                                                                                 
                                                                                     | 
                        
                            OPRW-1500S | 
                        Available upon quote | 
                                                                                                             
 Up to 0.6m to 15m  | 
                                                    
                                                                                                             
 Road surface snow depth, road surface condition, road surface temperature  | 
                                                    
                                                                                                             
 0-50cm (specified the measurement position as a scanning angle)  | 
                                                    
                                                                                                             
 -30.0-99.9 ℃  | 
                                                    
                                                                                                             
 ± 1cm (accuracy when a standard reflector is set to ± 0.1 ° C)  | 
                                                    
                                                                                                             
 ± 1 ° C (0.6%of the temperature difference between the road surface temperature and the sensor temperature is added)  | 
                                                    
                                                                                                             
 About 30 seconds  | 
                                                    
                                                                                                             
 About 5 seconds  | 
                                                    
                                                                                                             
 1cm  | 
                                                    
                                                                                                             
 0.1 ℃  | 
                                                    
                                                                                                             
 -10 ~+10 °  | 
                                                    
                                                                                                             
 Class 1 (JISC6802: 2005)  | 
                                                    
                                                                                                             
 Recommended angle: 20 ° from vertical (15-25 °)  | 
                                                    
                                                                                                             
 RS-485 signal (connected to a dedicated converter)  | 
                                                    
                                                                                                             
 Red laser wavelength for sensor positioning: 635nm, laser safety standard: class 2 (JISC6802: 2014)  | 
                                                    
                                                                                                             
 Can be connected to Pt100Ω (100ΩAT0 ℃)  | 
                                                    
                                                                                                             
 DC24V ± 10%  | 
                                                    
                                                                                                             
 450mA at normal (620mA when internal heater operation)  | 
                                                    
                                                                                                             
 -10 ~+50 ℃ (accuracy guarantee range)  | 
                                                    
                                                                                                             
 IP53 (dustproof / rainproof)  | 
                                                    
                                                                                                             
 Body case: Aluminum, painted color Mansel 5Y7/1 and a half  | 
                                                    
                                                                                                             
 429W x 367H x 318Dmm  | 
                                            