Crystal type water level meter (RS485 type) QSM series-QSM-S10-R1
Crystal type water level meter (RS485 type) QSM series-Takuwa

Crystal type water level meter (RS485 type) QSM series
Takuwa


About This Product

This device is a pressure -type water level meter that detects water levels from water pressure. The water level can be measured at a high precision to use the crystal vibration for pressure detection. The frequency of the crystal vibrator is converted to a water level and outputs at the serial signal of the RS-485. ・ The setting value is memorized in the sensor and the sensor setting after installation is not required. ・ RS485 is used to transmit up to 1.2km long distance. ・ RS485 achieves noise strong transmission performance.

  • Product

    Crystal type water level meter (RS485 type) QSM series




*Please note that we may not be able to accommodate sample requests.

10 Models of Crystal type water level meter (RS485 type) QSM series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Case material Current consumption current Environmental condition Maximum sensor cable Measurement accuracy Measurement method Measurement range Operating function Operation power supply voltage Output signal Overloading load Sensor cable outer diameter Sensor cable sheath material Sensor cable standard Temperature sensitivity coefficient Temperature zero -point coefficient mass size
Crystal type water level meter (RS485 type) QSM series-Part Number-QSM-S10-R1

QSM-S10-R1

Available upon quote SUS316L 20 mA or less when communication (always 10 mA or less) -10 ℃ ~ + 60 ° C (but not freezing) Up to 200m * Relay box -between conversion: Up to 1km using a connection cable (twist pair) High accuracy: ± 0.01 % FS Crystal oscillator 0 to 10m Water level operation function (constant C, D, T0 is internal internal record)/Average calculation/density correction, gravity acceleration correction, air pressure correction DC10.5V to 16.5V (rated DC12V) RS-485 signal 120 % FS Approximately φ12.5mm (finished outer diameter) Polyurethane sheath thickness 1mm Cable dedicated to ventilation pipes 0.0049 % FS/℃ ± 0.0007 % FS/℃ 3.0kg or less (sensor body) φ60 × 280L M M
Crystal type water level meter (RS485 type) QSM series-Part Number-QSM-S20-R1

QSM-S20-R1

Available upon quote SUS316L 20 mA or less when communication (always 10 mA or less) -10 ℃ ~ + 60 ° C (but not freezing) Up to 200m * Relay box -between conversion: Up to 1km using a connection cable (twist pair) High accuracy: ± 0.01 % FS Crystal oscillator 0 to 20m Water level operation function (constant C, D, T0 is internal internal record)/Average calculation/density correction, gravity acceleration correction, air pressure correction DC10.5V to 16.5V (rated DC12V) RS-485 signal 120 % FS Approximately φ12.5mm (finished outer diameter) Polyurethane sheath thickness 1mm Cable dedicated to ventilation pipes 0.0049 % FS/℃ ± 0.0007 % FS/℃ 3.0kg or less (sensor body) φ60 × 280L M M
Crystal type water level meter (RS485 type) QSM series-Part Number-QSM-S30-R1

QSM-S30-R1

Available upon quote SUS316L 20 mA or less when communication (always 10 mA or less) -10 ℃ ~ + 60 ° C (but not freezing) Up to 200m * Relay box -between conversion: Up to 1km using a connection cable (twist pair) High accuracy: ± 0.01 % FS Crystal oscillator 0 to 30m Water level operation function (constant C, D, T0 is internal internal record)/Average calculation/density correction, gravity acceleration correction, air pressure correction DC10.5V to 16.5V (rated DC12V) RS-485 signal 120 % FS Approximately φ12.5mm (finished outer diameter) Polyurethane sheath thickness 1mm Cable dedicated to ventilation pipes 0.0049 % FS/℃ ± 0.0007 % FS/℃ 3.0kg or less (sensor body) φ60 × 280L M M
Crystal type water level meter (RS485 type) QSM series-Part Number-QSM-S50-R1

QSM-S50-R1

Available upon quote SUS316L 20 mA or less when communication (always 10 mA or less) -10 ℃ ~ + 60 ° C (but not freezing) Up to 200m * Relay box -between conversion: Up to 1km using a connection cable (twist pair) High accuracy: ± 0.01 % FS Crystal oscillator 0 to 50m Water level operation function (constant C, D, T0 is internal internal record)/Average calculation/density correction, gravity acceleration correction, air pressure correction DC10.5V to 16.5V (rated DC12V) RS-485 signal 120 % FS Approximately φ12.5mm (finished outer diameter) Polyurethane sheath thickness 1mm Cable dedicated to ventilation pipes 0.0049 % FS/℃ ± 0.0007 % FS/℃ 3.0kg or less (sensor body) φ60 × 280L M M
Crystal type water level meter (RS485 type) QSM series-Part Number-QSM-S70-R1

QSM-S70-R1

Available upon quote SUS316L 20 mA or less when communication (always 10 mA or less) -10 ℃ ~ + 60 ° C (but not freezing) Up to 200m * Relay box -between conversion: Up to 1km using a connection cable (twist pair) High accuracy: ± 0.01 % FS Crystal oscillator 0 to 70m Water level operation function (constant C, D, T0 is internal internal record)/Average calculation/density correction, gravity acceleration correction, air pressure correction DC10.5V to 16.5V (rated DC12V) RS-485 signal 120 % FS Approximately φ12.5mm (finished outer diameter) Polyurethane sheath thickness 1mm Cable dedicated to ventilation pipes 0.0049 % FS/℃ ± 0.0007 % FS/℃ 3.0kg or less (sensor body) φ60 × 280L M M
Crystal type water level meter (RS485 type) QSM series-Part Number-QSM-H10-R1

QSM-H10-R1

Available upon quote SUS316L 20 mA or less when communication (always 10 mA or less) -10 ℃ ~ + 60 ° C (but not freezing) Up to 200m * Relay box -between conversion: Up to 1km using a connection cable (twist pair) High accuracy: ± 0.02 % FS Crystal oscillator 0 to 10m Water level operation function (constant C, D, T0 is internal internal record)/Average calculation/density correction, gravity acceleration correction, air pressure correction DC10.5V to 16.5V (rated DC12V) RS-485 signal 120 % FS Approximately φ12.5mm (finished outer diameter) Polyurethane sheath thickness 1mm Cable dedicated to ventilation pipes 0.0049 % FS/℃ ± 0.0007 % FS/℃ 3.0kg or less (sensor body) φ60 × 280L M M
Crystal type water level meter (RS485 type) QSM series-Part Number-QSM-H20-R1

QSM-H20-R1

Available upon quote SUS316L 20 mA or less when communication (always 10 mA or less) -10 ℃ ~ + 60 ° C (but not freezing) Up to 200m * Relay box -between conversion: Up to 1km using a connection cable (twist pair) High accuracy: ± 0.02 % FS Crystal oscillator 0 to 20m Water level operation function (constant C, D, T0 is internal internal record)/Average calculation/density correction, gravity acceleration correction, air pressure correction DC10.5V to 16.5V (rated DC12V) RS-485 signal 120 % FS Approximately φ12.5mm (finished outer diameter) Polyurethane sheath thickness 1mm Cable dedicated to ventilation pipes 0.0049 % FS/℃ ± 0.0007 % FS/℃ 3.0kg or less (sensor body) φ60 × 280L M M
Crystal type water level meter (RS485 type) QSM series-Part Number-QSM-H30-R1

QSM-H30-R1

Available upon quote SUS316L 20 mA or less when communication (always 10 mA or less) -10 ℃ ~ + 60 ° C (but not freezing) Up to 200m * Relay box -between conversion: Up to 1km using a connection cable (twist pair) High accuracy: ± 0.02 % FS Crystal oscillator 0 to 30m Water level operation function (constant C, D, T0 is internal internal record)/Average calculation/density correction, gravity acceleration correction, air pressure correction DC10.5V to 16.5V (rated DC12V) RS-485 signal 120 % FS Approximately φ12.5mm (finished outer diameter) Polyurethane sheath thickness 1mm Cable dedicated to ventilation pipes 0.0049 % FS/℃ ± 0.0007 % FS/℃ 3.0kg or less (sensor body) φ60 × 280L M M
Crystal type water level meter (RS485 type) QSM series-Part Number-QSM-H50-R1

QSM-H50-R1

Available upon quote SUS316L 20 mA or less when communication (always 10 mA or less) -10 ℃ ~ + 60 ° C (but not freezing) Up to 200m * Relay box -between conversion: Up to 1km using a connection cable (twist pair) High accuracy: ± 0.02 % FS Crystal oscillator 0 to 50m Water level operation function (constant C, D, T0 is internal internal record)/Average calculation/density correction, gravity acceleration correction, air pressure correction DC10.5V to 16.5V (rated DC12V) RS-485 signal 120 % FS Approximately φ12.5mm (finished outer diameter) Polyurethane sheath thickness 1mm Cable dedicated to ventilation pipes 0.0049 % FS/℃ ± 0.0007 % FS/℃ 3.0kg or less (sensor body) φ60 × 280L M M
Crystal type water level meter (RS485 type) QSM series-Part Number-QSM-H70-R1

QSM-H70-R1

Available upon quote SUS316L 20 mA or less when communication (always 10 mA or less) -10 ℃ ~ + 60 ° C (but not freezing) Up to 200m * Relay box -between conversion: Up to 1km using a connection cable (twist pair) High accuracy: ± 0.02 % FS Crystal oscillator 0 to 70m Water level operation function (constant C, D, T0 is internal internal record)/Average calculation/density correction, gravity acceleration correction, air pressure correction DC10.5V to 16.5V (rated DC12V) RS-485 signal 120 % FS Approximately φ12.5mm (finished outer diameter) Polyurethane sheath thickness 1mm Cable dedicated to ventilation pipes 0.0049 % FS/℃ ± 0.0007 % FS/℃ 3.0kg or less (sensor body) φ60 × 280L M M

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Takuwa


View more products of Takuwa

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree