All Categories
History
Product
Riverbed deposits TRS series (riverbed sedimentation meter)Handling Company
TakuwaImage | Part Number | Price (excluding tax) | composition | Measurement range | Measurement method | Measurement accuracy * | Output signal | Operation power supply voltage | Current consumption current | Environmental condition | Material | size | mass | Maximum cable | Cable length (designated length LM) | Sheath material | Cable outer diameter |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TRS-284-S30 |
Available upon quote |
2 units (upper row / lower) |
0-3m |
Conductive measurement method |
River floor position accuracy: ± 2cm, water surface position accuracy: ± 2cm ( * 4cm or more from the bottom) |
Sensor -dedicated signal output data: river floor position, water surface position |
DC3.1 to 3.8V (supplied from the converter) |
4.0mA or less (1 set of upper and lower steps) |
-10-60 ° C |
Sensor electrode: Stainless steel SUS304, Case: PC+ABS |
W86 x H3,156 x D30mm (but excluding protrusions) |
7.5kg or less (1 set of upper and lower steps) |
30m |
Upper L-1.6m Lower LM |
Polyurethane |
Approximately φ6mm (external diameter) |
Reviews shown here are reviews of companies.