From clean rooms to air pollution High concentration/multi-channel (30 particle sizes) particle counter Model9000/9000-loT seriesHandling Company
Particles Plus, Inc.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply/standard | Counting efficiency | Particle size number (particle size channel-CH) | Particle size | Measurement time/mode | Flow monitor | Flow rate | Particle size during calibration | Minimum measurable particle size selection | Maximum measurable concentration approx. | Exterior/dimensions/weight | Measurable particle size range um | Operating/storage environment temperature and humidity | Processing section | Light source/receiver | False counting | Included software | Number of memory | Pump presence/absence selection | Communication standard type | Communication Common/Direct connection to PC | Communication IoT type | Optional environmental sensor | Optional mounting bracket/stand | Optional USB-RS485 (PCA) adapter | Error indicator | Alarm settings | Exhaust filter | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
9300 |
Available upon quote |
9-24VDC (<2.5W) / ISO21501-4, JIS B9921 (excluding optional environmental sensor) |
50%@0.3μm・100%@>0.45μm at PSL |
Select up to 6 particle sizes (6CH) during calibration and up to 30 particle sizes (30CH) during use. |
Particle size set by user (300nm-10,000nm) IMS-9K software included |
Minimum 1 second ~ maximum 9,999 hours/1 time, repeat mode (sample amount (time) + pause) xN |
Constantly monitor flow rate with internal flow sensor (error display at ±5%) |
1.2L/min |
0.3μm, 0.5μm, 1.0μm, 2.5μm, 5.0μm, 10.0μm |
Type with minimum measurable particle size of 0.3μm |
1,770/CC |
SUS316 / 91mmW x 46mmD x 143mmH / 0.78kg |
0.3μm~10.0μm |
5℃-40℃, 20%-95%RH / 0℃-50℃, 98%RH, non-condensing |
Computer Windows 10 or higher (sold separately) |
Long-life semiconductor laser (2 years warranty) / Photodiode |
1 count or less/60 minutes |
IMS-9K counter control/data download (Excel CSV file) |
65,000, delete from the beginning on overflow |
None *Use critical orifice or external metering pump |
Modbus RTU, Isolated RS485 (standard) |
USB-Mini-USB cable 1.8m (common) |
TCP/IP-RJ45 connector (Ethernet) (optional) |
Environmental sensor probe (temperature/humidity sensor/barometric pressure sensor/CO2 sensor) (factory option) |
Stay fishing mount placket/simple stand |
RS485-PC external connection cable/connector |
When an error (flow, exceeding a set alarm, sensor, etc.) occurs, an orange LED at the base of the inlet will alert you. |
Set by particle number and mass (interval raw value, cumulative raw value, same m3 conversion, same CF conversion) for each particle size. |
- |
110V-240VAC-12VDC converter, barge filter, ISO probe |
|
9300P |
Available upon quote |
9-24VDC (<2.5W) / ISO21501-4, JIS B9921 (excluding optional environmental sensor) |
50%@0.3μm・100%@>0.45μm at PSL |
Select up to 6 particle sizes (6CH) during calibration and up to 30 particle sizes (30CH) during use. |
Particle size set by user (300nm-10,000nm) IMS-9K software included |
Minimum 1 second ~ maximum 9,999 hours/1 time, repeat mode (sample amount (time) + pause) xN |
Constantly monitor flow rate with internal flow sensor (error display at ±5%) |
1.2L/min |
0.3μm, 0.5μm, 1.0μm, 2.5μm, 5.0μm, 10.0μm |
Type with minimum measurable particle size of 0.3μm |
1,770/CC |
SUS316 / 91mmW x 46mmD x 143mmH / 0.78kg |
0.3μm~10.0μm |
5℃-40℃, 20%-95%RH / 0℃-50℃, 98%RH, non-condensing |
Computer Windows 10 or higher (sold separately) |
Long-life semiconductor laser (2 years warranty) / Photodiode |
1 count or less/60 minutes |
IMS-9K counter control/data download (Excel CSV file) |
65,000, delete from the beginning on overflow |
Built-in * Equipped with an in-house developed rotary vane pump, estimated lifespan of 1 year when used continuously for 24 hours |
Modbus RTU, Isolated RS485 (standard) |
USB-Mini-USB cable 1.8m (common) |
TCP/IP-RJ45 connector (Ethernet) (optional) |
Environmental sensor probe (temperature/humidity sensor/barometric pressure sensor/CO2 sensor) (factory option) |
Stay fishing mount placket/simple stand |
RS485-PC external connection cable/connector |
When an error (flow, exceeding a set alarm, sensor, etc.) occurs, an orange LED at the base of the inlet will alert you. |
Set by particle number and mass (interval raw value, cumulative raw value, same m3 conversion, same CF conversion) for each particle size. |
HEPA *Built-in pump type exhausts via HEPA. HEPA can be removed if there is no need to consider environmental pollution effects (pump load reduction) Factory option |
110V-240VAC-12VDC converter, barge filter, ISO probe |
|
9301 |
Available upon quote |
9-24VDC (<2.5W) / ISO21501-4, JIS B9921 (excluding optional environmental sensor) |
50%@0.3μm・100%@>0.45μm at PSL |
Select up to 6 particle sizes (6CH) during calibration and up to 30 particle sizes (30CH) during use. |
Particle size set by user (300nm-10,000nm) IMS-9K software included |
Minimum 1 second ~ maximum 9,999 hours/1 time, repeat mode (sample amount (time) + pause) xN |
Constantly monitor flow rate with internal flow sensor (error display at ±5%) |
2.83L/min |
0.3μm, 0.5μm, 1.0μm, 2.5μm, 5.0μm, 10.0μm |
Type with minimum measurable particle size of 0.3μm |
710/CC |
SUS316 / 91mmW x 46mmD x 143mmH / 0.78kg |
0.3μm~10.0μm |
5℃-40℃, 20%-95%RH / 0℃-50℃, 98%RH, non-condensing |
Computer Windows 10 or higher (sold separately) |
Long-life semiconductor laser (2 years warranty) / Photodiode |
1 count or less/60 minutes |
IMS-9K counter control/data download (Excel CSV file) |
65,000, delete from the beginning on overflow |
None *Use critical orifice or external metering pump |
Modbus RTU, Isolated RS485 (standard) |
USB-Mini-USB cable 1.8m (common) |
TCP/IP-RJ45 connector (Ethernet) (optional) |
Environmental sensor probe (temperature/humidity sensor/barometric pressure sensor/CO2 sensor) (factory option) |
Stay fishing mount placket/simple stand |
RS485-PC external connection cable/connector |
When an error (flow, exceeding a set alarm, sensor, etc.) occurs, an orange LED at the base of the inlet will alert you. |
Set by particle number and mass (interval raw value, cumulative raw value, same m3 conversion, same CF conversion) for each particle size. |
- |
110V-240VAC-12VDC converter, barge filter, ISO probe |
|
9301P |
Available upon quote |
9-24VDC (<2.5W) / ISO21501-4, JIS B9921 (excluding optional environmental sensor) |
50%@0.3μm・100%@>0.45μm at PSL |
Select up to 6 particle sizes (6CH) during calibration and up to 30 particle sizes (30CH) during use. |
Particle size set by user (300nm-10,000nm) IMS-9K software included |
Minimum 1 second ~ maximum 9,999 hours/1 time, repeat mode (sample amount (time) + pause) xN |
Constantly monitor flow rate with internal flow sensor (error display at ±5%) |
2.83L/min |
0.3μm, 0.5μm, 1.0μm, 2.5μm, 5.0μm, 10.0μm |
Type with minimum measurable particle size of 0.3μm |
710/CC |
SUS316 / 91mmW x 46mmD x 143mmH / 0.78kg |
0.3μm~10.0μm |
5℃-40℃, 20%-95%RH / 0℃-50℃, 98%RH, non-condensing |
Computer Windows 10 or higher (sold separately) |
Long-life semiconductor laser (2 years warranty) / Photodiode |
1 count or less/60 minutes |
IMS-9K counter control/data download (Excel CSV file) |
65,000, delete from the beginning on overflow |
Built-in * Equipped with an in-house developed rotary vane pump, estimated lifespan of 1 year when used continuously for 24 hours |
Modbus RTU, Isolated RS485 (standard) |
USB-Mini-USB cable 1.8m (common) |
TCP/IP-RJ45 connector (Ethernet) (optional) |
Environmental sensor probe (temperature/humidity sensor/barometric pressure sensor/CO2 sensor) (factory option) |
Stay fishing mount placket/simple stand |
RS485-PC external connection cable/connector |
When an error (flow, exceeding a set alarm, sensor, etc.) occurs, an orange LED at the base of the inlet will alert you. |
Set by particle number and mass (interval raw value, cumulative raw value, same m3 conversion, same CF conversion) for each particle size. |
HEPA *Built-in pump type exhausts via HEPA. HEPA can be removed if there is no need to consider environmental pollution effects (pump load reduction) Factory option |
110V-240VAC-12VDC converter, barge filter, ISO probe |
|
9500 |
Available upon quote |
9-24VDC (<2.5W) / ISO21501-4, JIS B9921 (excluding optional environmental sensor) |
50%@0.5μm・100%@>0.75μm at PSL |
Select up to 6 particle sizes (6CH) during calibration and up to 30 particle sizes (30CH) during use. |
Particle size set by user (300nm-10,000nm) IMS-9K software included |
Minimum 1 second ~ maximum 9,999 hours/1 time, repeat mode (sample amount (time) + pause) xN |
Constantly monitor flow rate with internal flow sensor (error display at ±5%) |
1.2L/min |
0.5μm, 0.7μm, 1.0μm, 2.5μm, 5.0μm, 10.0μm |
Type with minimum measurable particle size of 0.5μm |
1,770/CC |
SUS316 / 91mmW x 46mmD x 143mmH / 0.78kg |
0.5μm~10.0μm |
5℃-40℃, 20%-95%RH / 0℃-50℃, 98%RH, non-condensing |
Computer Windows 10 or higher (sold separately) |
Long-life semiconductor laser (2 years warranty) / Photodiode |
1 count or less/60 minutes |
IMS-9K counter control/data download (Excel CSV file) |
65,000, delete from the beginning on overflow |
None *Use critical orifice or external metering pump |
Modbus RTU, Isolated RS485 (standard) |
USB-Mini-USB cable 1.8m (common) |
TCP/IP-RJ45 connector (Ethernet) (optional) |
Environmental sensor probe (temperature/humidity sensor/barometric pressure sensor/CO2 sensor) (factory option) |
Stay fishing mount placket/simple stand |
RS485-PC external connection cable/connector |
When an error (flow, exceeding a set alarm, sensor, etc.) occurs, an orange LED at the base of the inlet will alert you. |
Set by particle number and mass (interval raw value, cumulative raw value, same m3 conversion, same CF conversion) for each particle size. |
- |
110V-240VAC-12VDC converter, barge filter, ISO probe |
|
9500P |
Available upon quote |
9-24VDC (<2.5W) / ISO21501-4, JIS B9921 (excluding optional environmental sensor) |
50%@0.5μm・100%@>0.75μm at PSL |
Select up to 6 particle sizes (6CH) during calibration and up to 30 particle sizes (30CH) during use. |
Particle size set by user (300nm-10,000nm) IMS-9K software included |
Minimum 1 second ~ maximum 9,999 hours/1 time, repeat mode (sample amount (time) + pause) xN |
Constantly monitor flow rate with internal flow sensor (error display at ±5%) |
1.2L/min |
0.5μm, 0.7μm, 1.0μm, 2.5μm, 5.0μm, 10.0μm |
Type with minimum measurable particle size of 0.5μm |
1,770/CC |
SUS316 / 91mmW x 46mmD x 143mmH / 0.78kg |
0.5μm~10.0μm |
5℃-40℃, 20%-95%RH / 0℃-50℃, 98%RH, non-condensing |
Computer Windows 10 or higher (sold separately) |
Long-life semiconductor laser (2 years warranty) / Photodiode |
1 count or less/60 minutes |
IMS-9K counter control/data download (Excel CSV file) |
65,000, delete from the beginning on overflow |
Built-in * Equipped with an in-house developed rotary vane pump, estimated lifespan of 1 year when used continuously for 24 hours |
Modbus RTU, Isolated RS485 (standard) |
USB-Mini-USB cable 1.8m (common) |
TCP/IP-RJ45 connector (Ethernet) (optional) |
Environmental sensor probe (temperature/humidity sensor/barometric pressure sensor/CO2 sensor) (factory option) |
Stay fishing mount placket/simple stand |
RS485-PC external connection cable/connector |
When an error (flow, exceeding a set alarm, sensor, etc.) occurs, an orange LED at the base of the inlet will alert you. |
Set by particle number and mass (interval raw value, cumulative raw value, same m3 conversion, same CF conversion) for each particle size. |
HEPA *Built-in pump type exhausts via HEPA. HEPA can be removed if there is no need to consider environmental pollution effects (pump load reduction) Factory option |
110V-240VAC-12VDC converter, barge filter, ISO probe |
|
9501 |
Available upon quote |
9-24VDC (<2.5W) / ISO21501-4, JIS B9921 (excluding optional environmental sensor) |
50%@0.5μm・100%@>0.75μm at PSL |
Select up to 6 particle sizes (6CH) during calibration and up to 30 particle sizes (30CH) during use. |
Particle size set by user (300nm-10,000nm) IMS-9K software included |
Minimum 1 second ~ maximum 9,999 hours/1 time, repeat mode (sample amount (time) + pause) xN |
Constantly monitor flow rate with internal flow sensor (error display at ±5%) |
2.83L/min |
0.5μm, 0.7μm, 1.0μm, 2.5μm, 5.0μm, 10.0μm |
Type with minimum measurable particle size of 0.5μm |
710/CC |
SUS316 / 91mmW x 46mmD x 143mmH / 0.78kg |
0.5μm~10.0μm |
5℃-40℃, 20%-95%RH / 0℃-50℃, 98%RH, non-condensing |
Computer Windows 10 or higher (sold separately) |
Long-life semiconductor laser (2 years warranty) / Photodiode |
1 count or less/60 minutes |
IMS-9K counter control/data download (Excel CSV file) |
65,000, delete from the beginning on overflow |
None *Use critical orifice or external metering pump |
Modbus RTU, Isolated RS485 (standard) |
USB-Mini-USB cable 1.8m (common) |
TCP/IP-RJ45 connector (Ethernet) (optional) |
Environmental sensor probe (temperature/humidity sensor/barometric pressure sensor/CO2 sensor) (factory option) |
Stay fishing mount placket/simple stand |
RS485-PC external connection cable/connector |
When an error (flow, exceeding a set alarm, sensor, etc.) occurs, an orange LED at the base of the inlet will alert you. |
Set by particle number and mass (interval raw value, cumulative raw value, same m3 conversion, same CF conversion) for each particle size. |
- |
110V-240VAC-12VDC converter, barge filter, ISO probe |
|
9501P |
Available upon quote |
9-24VDC (<2.5W) / ISO21501-4, JIS B9921 (excluding optional environmental sensor) |
50%@0.5μm・100%@>0.75μm at PSL |
Select up to 6 particle sizes (6CH) during calibration and up to 30 particle sizes (30CH) during use. |
Particle size set by user (300nm-10,000nm) IMS-9K software included |
Minimum 1 second ~ maximum 9,999 hours/1 time, repeat mode (sample amount (time) + pause) xN |
Constantly monitor flow rate with internal flow sensor (error display at ±5%) |
2.83L/min |
0.5μm, 0.7μm, 1.0μm, 2.5μm, 5.0μm, 10.0μm |
Type with minimum measurable particle size of 0.5μm |
710/CC |
SUS316 / 91mmW x 46mmD x 143mmH / 0.78kg |
0.5μm~10.0μm |
5℃-40℃, 20%-95%RH / 0℃-50℃, 98%RH, non-condensing |
Computer Windows 10 or higher (sold separately) |
Long-life semiconductor laser (2 years warranty) / Photodiode |
1 count or less/60 minutes |
IMS-9K counter control/data download (Excel CSV file) |
65,000, delete from the beginning on overflow |
Built-in * Equipped with an in-house developed rotary vane pump, estimated lifespan of 1 year when used continuously for 24 hours |
Modbus RTU, Isolated RS485 (standard) |
USB-Mini-USB cable 1.8m (common) |
TCP/IP-RJ45 connector (Ethernet) (optional) |
Environmental sensor probe (temperature/humidity sensor/barometric pressure sensor/CO2 sensor) (factory option) |
Stay fishing mount placket/simple stand |
RS485-PC external connection cable/connector |
When an error (flow, exceeding a set alarm, sensor, etc.) occurs, an orange LED at the base of the inlet will alert you. |
Set by particle number and mass (interval raw value, cumulative raw value, same m3 conversion, same CF conversion) for each particle size. |
HEPA *Built-in pump type exhausts via HEPA. HEPA can be removed if there is no need to consider environmental pollution effects (pump load reduction) Factory option |
110V-240VAC-12VDC converter, barge filter, ISO probe |
|
9510 |
Available upon quote |
9-24VDC (<2.5W) / ISO21501-4, JIS B9921 (excluding optional environmental sensor) |
50%@0.5μm・100%@>0.75μm at PSL |
Select up to 6 particle sizes (6CH) during calibration and up to 30 particle sizes (30CH) during use. |
Particle size set by user (300nm-10,000nm) IMS-9K software included |
Minimum 1 second ~ maximum 9,999 hours/1 time, repeat mode (sample amount (time) + pause) xN |
Constantly monitor flow rate with internal flow sensor (error display at ±5%) |
2.83L/min |
0.5μm, 0.7μm, 1.0μm, 2.5μm, 5.0μm, 10.0μm |
Type with minimum measurable particle size of 0.5μm |
71/CC |
SUS316 / 91mmW x 46mmD x 143mmH / 0.78kg |
0.5μm~10.0μm |
5℃-40℃, 20%-95%RH / 0℃-50℃, 98%RH, non-condensing |
Computer Windows 10 or higher (sold separately) |
Long-life semiconductor laser (2 years warranty) / Photodiode |
1 count or less/60 minutes |
IMS-9K counter control/data download (Excel CSV file) |
65,000, delete from the beginning on overflow |
None *Use critical orifice or external metering pump |
Modbus RTU, Isolated RS485 (standard) |
USB-Mini-USB cable 1.8m (common) |
TCP/IP-RJ45 connector (Ethernet) (optional) |
Environmental sensor probe (temperature/humidity sensor/barometric pressure sensor/CO2 sensor) (factory option) |
Stay fishing mount placket/simple stand |
RS485-PC external connection cable/connector |
When an error (flow, exceeding a set alarm, sensor, etc.) occurs, an orange LED at the base of the inlet will alert you. |
Set by particle number and mass (interval raw value, cumulative raw value, same m3 conversion, same CF conversion) for each particle size. |
- |
110V-240VAC-12VDC converter, barge filter, ISO probe |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.