Product
FJX-FTHandling Company
Wakuren KogyoProduct Image | Part Number | Price (excluding tax) | Lever part strength (1 minute for static loading) Vertical direction | Lever portion strength (1 minute for static loading) front, rear, left and right directions | Lever portion strength (1 minute with a static load) twist (torque) | Lever repeated durability | Operability | Operating temperature limit | Operation angle from the neutral position | Potenchaometer Static electricity resistance | Potenchaometer applied voltage | Potenchaometer current consumption | Potenchaometer effective electric angle | Potenchaometer electromagnetic resistance | Potenchaometer output voltage range | Returning to neutral | Vibration resistance | Water resistance (upper surface, outside panel) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FJX-FT |
Available upon quote | 29N | 98N (lever tip) | 98n cm | 5 million times | 2.0 ± 0.5N (0 °) to 3.0 ± 0.5N (± 30 °) | -40 ° C to+70 ° C (excluding freezing and harness) | ± 30 ° | Apply 3 times each of the static electric voltage to the terminal within 1 second of a period of ± 4KV and do not destroy it. | DC5V ± 0.5V | 22 ma or less | ± 28 ° (proportional output range) | 100V/m, 1-1000MHz output fluctuation ± 1%VIN | 0.5V to 4.5V | Automatic (spring system) | JISD16013 Type A Type 45 | JISC0920IP65 or higher (top of the panel) |