Back pressure type level switch LT1-LT1-ANNA
Back pressure type level switch LT1-RKC INSTRUMENT

Back pressure type level switch LT1
RKC INSTRUMENT


About This Product

■Detect upper and lower limit levels of liquid with one tube ・Outputs the level when the tube tip touches the liquid surface as an alarm. ・If PFA tube is used, it can also be used with corrosive chemicals. ■High reliability A semiconductor pressure sensor (back pressure sensor) is used in the sensor section. High reliability and reproducibility are achieved due to the structure without mechanical drive parts. ■No adjustment required ・Set the tube length to your desired length and you're ready to go. - Built-in orifice in the main body. If you supply air gas of 20±1kPa, it will automatically reach the specified purge flow rate for the main unit. *Other product numbers are available.

  • Product

    Back pressure type level switch LT1

Share this product


190+ people viewing

Last viewed: 12 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Back pressure type level switch LT1

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Detection tube inner diameter Detection tube length Hysteresis Input media consumption Input medium Input medium pressure Input pressure range Installation method Insulation resistance Mass Mounting position Number of input points Number of output points Output display Output type Permissible ambient humidity Permissible ambient temperature Power consumption Power display Power supply voltage Response time Sensitivity Type Withstand voltage
Back pressure type level switch LT1-Part Number-LT1-ANNA

LT1-ANNA

Available upon quote Φ4mm Max 5m Within 3 seconds 40~100ml/min Non-corrosive gas 20~49kPa 0~49kPa 4 locations on the bottom (M3 screws) Between power supply terminal and output terminal 500V DC 20MΩ or more Approximately 250g Position higher than the measured liquid level 1 point Excitation Green LED on Relay contact output 1c contact
AC250V 3A (resistive load), DC30V 3A
35~85%RH (no condensation) 0~50℃ Maximum 45mA or less (DC24V) *At maximum load Green LED on DC21.6~26.4V (including power supply voltage fluctuation) (rated DC24V) 0.2 seconds Standard Main unit alone Between power supply terminal and output terminal 2,300V AC for 1 minute
Back pressure type level switch LT1-Part Number-LT1-BNNA

LT1-BNNA

Available upon quote Φ4mm Max 5m Within 3 seconds 40~100ml/min Non-corrosive gas 20~49kPa 0~49kPa 4 locations on the bottom (M3 screws) Between power supply terminal and output terminal 500V DC 20MΩ or more Approximately 250g Position higher than the measured liquid level 1 point De-energized Green LED on Relay contact output 1c contact
AC250V 3A (resistive load), DC30V 3A
35~85%RH (no condensation) 0~50℃ Maximum 45mA or less (DC24V) *At maximum load Green LED on DC21.6~26.4V (including power supply voltage fluctuation) (rated DC24V) 0.2 seconds Standard Main unit alone Between power supply terminal and output terminal 2,300V AC for 1 minute
Back pressure type level switch LT1-Part Number-LT1-1M-A

LT1-1M-A

Available upon quote Φ4mm Max 5m Within 3 seconds 40~100ml/min Non-corrosive gas 20~49kPa 0~49kPa 4 locations on the bottom (M3 screws) Between power supply terminal and output terminal 500V DC 20MΩ or more Approximately 250g Position higher than the measured liquid level 1 point Relay output excitation type Green LED on Relay contact output 1c contact
AC250V 3A (resistive load), DC30V 3A
35~85%RH (no condensation) 0~50℃ Maximum 45mA or less (DC24V) *At maximum load Green LED on DC21.6~26.4V (including power supply voltage fluctuation) (rated DC24V) 0.2 seconds Standard Connected type (bracket + main body) 1 unit connected
*Connection fittings are included.
Between power supply terminal and output terminal 2,300V AC for 1 minute
Back pressure type level switch LT1-Part Number-LT1-1M-B

LT1-1M-B

Available upon quote Φ4mm Max 5m Within 3 seconds 40~100ml/min Non-corrosive gas 20~49kPa 0~49kPa 4 locations on the bottom (M3 screws) Between power supply terminal and output terminal 500V DC 20MΩ or more Approximately 250g Position higher than the measured liquid level 1 point Relay output de-energized type Green LED on Relay contact output 1c contact
AC250V 3A (resistive load), DC30V 3A
35~85%RH (no condensation) 0~50℃ Maximum 45mA or less (DC24V) *At maximum load Green LED on DC21.6~26.4V (including power supply voltage fluctuation) (rated DC24V) 0.2 seconds Standard Connected type (bracket + main body) 1 unit connected
*Connection fittings are included.
Between power supply terminal and output terminal 2,300V AC for 1 minute
Back pressure type level switch LT1-Part Number-LT1-1M-AA

LT1-1M-AA

Available upon quote Φ4mm Max 5m Within 3 seconds 40~100ml/min Non-corrosive gas 20~49kPa 0~49kPa 4 locations on the bottom (M3 screws) Between power supply terminal and output terminal 500V DC 20MΩ or more Approximately 250g Position higher than the measured liquid level 1 point Relay output excitation type Green LED on Relay contact output 1c contact
AC250V 3A (resistive load), DC30V 3A
35~85%RH (no condensation) 0~50℃ Maximum 45mA or less (DC24V) *At maximum load Green LED on DC21.6~26.4V (including power supply voltage fluctuation) (rated DC24V) 0.2 seconds Standard Connected type (bracket + main body) 2 units connected
*Connection fittings are included.
Between power supply terminal and output terminal 2,300V AC for 1 minute
Back pressure type level switch LT1-Part Number-LT1-1M-BB

LT1-1M-BB

Available upon quote Φ4mm Max 5m Within 3 seconds 40~100ml/min Non-corrosive gas 20~49kPa 0~49kPa 4 locations on the bottom (M3 screws) Between power supply terminal and output terminal 500V DC 20MΩ or more Approximately 250g Position higher than the measured liquid level 1 point Relay output de-energized type Green LED on Relay contact output 1c contact
AC250V 3A (resistive load), DC30V 3A
35~85%RH (no condensation) 0~50℃ Maximum 45mA or less (DC24V) *At maximum load Green LED on DC21.6~26.4V (including power supply voltage fluctuation) (rated DC24V) 0.2 seconds Standard Connected type (bracket + main body) 2 units connected
*Connection fittings are included.
Between power supply terminal and output terminal 2,300V AC for 1 minute
Back pressure type level switch LT1-Part Number-LT1-1M-AAA

LT1-1M-AAA

Available upon quote Φ4mm Max 5m Within 3 seconds 40~100ml/min Non-corrosive gas 20~49kPa 0~49kPa 4 locations on the bottom (M3 screws) Between power supply terminal and output terminal 500V DC 20MΩ or more Approximately 250g Position higher than the measured liquid level 1 point Relay output excitation type Green LED on Relay contact output 1c contact
AC250V 3A (resistive load), DC30V 3A
35~85%RH (no condensation) 0~50℃ Maximum 45mA or less (DC24V) *At maximum load Green LED on DC21.6~26.4V (including power supply voltage fluctuation) (rated DC24V) 0.2 seconds Standard Connected type (bracket + main body) 3 units connected
*Connection fittings are included.
Between power supply terminal and output terminal 2,300V AC for 1 minute
Back pressure type level switch LT1-Part Number-LT1-1M-BBB

LT1-1M-BBB

Available upon quote Φ4mm Max 5m Within 3 seconds 40~100ml/min Non-corrosive gas 20~49kPa 0~49kPa 4 locations on the bottom (M3 screws) Between power supply terminal and output terminal 500V DC 20MΩ or more Approximately 250g Position higher than the measured liquid level 1 point Relay output de-energized type Green LED on Relay contact output 1c contact
AC250V 3A (resistive load), DC30V 3A
35~85%RH (no condensation) 0~50℃ Maximum 45mA or less (DC24V) *At maximum load Green LED on DC21.6~26.4V (including power supply voltage fluctuation) (rated DC24V) 0.2 seconds Standard Connected type (bracket + main body) 3 units connected
*Connection fittings are included.
Between power supply terminal and output terminal 2,300V AC for 1 minute
Back pressure type level switch LT1-Part Number-LT1-1M-AAAA

LT1-1M-AAAA

Available upon quote Φ4mm Max 5m Within 3 seconds 40~100ml/min Non-corrosive gas 20~49kPa 0~49kPa 4 locations on the bottom (M3 screws) Between power supply terminal and output terminal 500V DC 20MΩ or more Approximately 250g Position higher than the measured liquid level 1 point Relay output excitation type Green LED on Relay contact output 1c contact
AC250V 3A (resistive load), DC30V 3A
35~85%RH (no condensation) 0~50℃ Maximum 45mA or less (DC24V) *At maximum load Green LED on DC21.6~26.4V (including power supply voltage fluctuation) (rated DC24V) 0.2 seconds Standard Connected type (bracket + main body) 4 units connected
*Connection fittings are included.
Between power supply terminal and output terminal 2,300V AC for 1 minute
Back pressure type level switch LT1-Part Number-LT1-1M-BBBB

LT1-1M-BBBB

Available upon quote Φ4mm Max 5m Within 3 seconds 40~100ml/min Non-corrosive gas 20~49kPa 0~49kPa 4 locations on the bottom (M3 screws) Between power supply terminal and output terminal 500V DC 20MΩ or more Approximately 250g Position higher than the measured liquid level 1 point Relay output de-energized type Green LED on Relay contact output 1c contact
AC250V 3A (resistive load), DC30V 3A
35~85%RH (no condensation) 0~50℃ Maximum 45mA or less (DC24V) *At maximum load Green LED on DC21.6~26.4V (including power supply voltage fluctuation) (rated DC24V) 0.2 seconds Standard Connected type (bracket + main body) 4 units connected
*Connection fittings are included.
Between power supply terminal and output terminal 2,300V AC for 1 minute

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of RKC INSTRUMENT


View more products of RKC INSTRUMENT

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree