Capacitive level sensor/level meter RMC500-RMC-500B3*ANN-NNN
Capacitive level sensor/level meter RMC500-RKC INSTRUMENT

Capacitive level sensor/level meter RMC500
RKC INSTRUMENT


About This Product

■Full digital control capacitance level meter The conventional analog control has been improved to digital control, resulting in a significant improvement in operability. ■Advantages of capacitive type ・Continuous level measurement possible: Level can be measured continuously from 0 to 100% level. - Capable of highly accurate and reproducible measurements: There are no mechanical moving parts, and measurements can be made with reproducibility in mm units. Easy adjustments and reproducible measurements made possible by digital control ■Simply set the level between 0% (zero) and 100% (span). Auto zero-span adjustment using actual liquid: If you put the actual liquid into the tank and register the desired points for zero (0%) and span (100%) in advance, the 0 to 100% level will be automatically adjusted within that range. Measurement adjustment is complete. ■We can also handle tanks with complex shapes. Actual liquid linearization adjustment: Register each level value at each liquid level position at each inflection point of the tank. It can also be used for tanks with complex shapes where capacitance changes do not appear linearly with respect to liquid level. *If the setting is made across inflection points, or if the distance between the inflection points is not linear, satisfactory accuracy may not be obtained. ■Other special adjustments Span adjustment when the actual liquid is at a low position, zero adjustment when the actual liquid is at a high position: Even if the actual liquid cannot be set to zero (0%) or span (100%), the zero/span level is automatically calculated and set. ■Data can be managed via communication Can be equipped with RS-485/loader communication: Data management by a host computer or PLC and various settings of RMC-500 are possible. *Other product numbers are available.

  • Product

    Capacitive level sensor/level meter RMC500

Share this product


150+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Capacitive level sensor/level meter RMC500

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Ambient temperature Analog transmission output (optional) Calibration function Communication function Contents of the output Data backup Digital (alarm) output Factory settings (event function/communication protocol specification) Input accuracy Input range Inrush current (at maximum load) Insulation resistance Insulation voltage Loader communication function Address setting Loader communication function Communication speed Loader communication function Data format Loader communication function Maximum number of connection points Loader communication function protocol Mass Measurement input correction function Number of input points Optional feature 2 Output type Power consumption Power outage processing Power supply voltage Reference input function Safety standards Sampling period Waterproof and dustproof structure
Capacitive level sensor/level meter RMC500-Part Number-RMC-500B3*ANN-NNN

RMC-500B3*ANN-NNN

Available upon quote -10~+55℃ No analog transmission output Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function No communication function Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action Data backup using non-volatile memory
Number of rewrites: 1 million times
Data storage retention period: Approximately 10 years
With 6 points (DO1~DO6) None (Shipped at shipping value) Linearity error ±0.1% of input span (B, C type) 0~200pF 12A or less Between measurement terminal and ground: DC500V 20MΩ or more
Between power terminal and ground: DC500V 20MΩ or more
Between power supply terminal and measurement terminal: DC500V 20MΩ or more
Between measurement terminal and ground: AC1,500V for 1 minute
Between power terminal and ground: AC1,500V for 1 minute
Between power supply terminal and measurement terminal: AC2,300V for 1 minute
Fixed at 0 38,400bps RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit 1 point (COM-K only) RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant Approximately 180g Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment 1 point No optional feature 2 Relay contact output, 1a contact At AC24V: 8VA or less
At DC24V: 220mA or less
Operation is not affected by power outages of 20msec or less AC/DC24V No reference input function UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE marking: Low Voltage Directive (LVD) EN61010-1
EMC Directive: EN61326-1
RCM: EN55011
0.1 seconds IP66 NEMA4X *However, only in the front direction when mounted on a panel
Capacitive level sensor/level meter RMC500-Part Number-RMC-500B3*ANN-1NN

RMC-500B3*ANN-1NN

Available upon quote -10~+55℃ No analog transmission output Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function No communication function Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action Data backup using non-volatile memory
Number of rewrites: 1 million times
Data storage retention period: Approximately 10 years
With 6 points (DO1~DO6) None (Shipped at shipping value) Linearity error ±0.1% of input span (B, C type) 0~200pF 12A or less Between measurement terminal and ground: DC500V 20MΩ or more
Between power terminal and ground: DC500V 20MΩ or more
Between power supply terminal and measurement terminal: DC500V 20MΩ or more
Between measurement terminal and ground: AC1,500V for 1 minute
Between power terminal and ground: AC1,500V for 1 minute
Between power supply terminal and measurement terminal: AC2,300V for 1 minute
Fixed at 0 38,400bps RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit 1 point (COM-K only) RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant Approximately 180g Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment 1 point No optional feature 2 Relay contact output, 1a contact At AC24V: 8VA or less
At DC24V: 220mA or less
Operation is not affected by power outages of 20msec or less AC/DC24V With reference input function UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE marking: Low Voltage Directive (LVD) EN61010-1
EMC Directive: EN61326-1
RCM: EN55011
0.1 seconds IP66 NEMA4X *However, only in the front direction when mounted on a panel
Capacitive level sensor/level meter RMC500-Part Number-RMC-500B3*AN5-NNN

RMC-500B3*AN5-NNN

Available upon quote -10~+55℃ No analog transmission output Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function RS-485 Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action Data backup using non-volatile memory
Number of rewrites: 1 million times
Data storage retention period: Approximately 10 years
With 6 points (DO1~DO6) None (Shipped at shipping value) Linearity error ±0.1% of input span (B, C type) 0~200pF 12A or less Between measurement terminal and ground: DC500V 20MΩ or more
Between power terminal and ground: DC500V 20MΩ or more
Between power supply terminal and measurement terminal: DC500V 20MΩ or more
Between measurement terminal and ground: AC1,500V for 1 minute
Between power terminal and ground: AC1,500V for 1 minute
Between power supply terminal and measurement terminal: AC2,300V for 1 minute
Fixed at 0 38,400bps RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit 1 point (COM-K only) RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant Approximately 180g Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment 1 point No optional feature 2 Relay contact output, 1a contact At AC24V: 8VA or less
At DC24V: 220mA or less
Operation is not affected by power outages of 20msec or less AC/DC24V No reference input function UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE marking: Low Voltage Directive (LVD) EN61010-1
EMC Directive: EN61326-1
RCM: EN55011
0.1 seconds IP66 NEMA4X *However, only in the front direction when mounted on a panel
Capacitive level sensor/level meter RMC500-Part Number-RMC-500B3*AN5-1NN

RMC-500B3*AN5-1NN

Available upon quote -10~+55℃ No analog transmission output Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function RS-485 Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action Data backup using non-volatile memory
Number of rewrites: 1 million times
Data storage retention period: Approximately 10 years
With 6 points (DO1~DO6) None (Shipped at shipping value) Linearity error ±0.1% of input span (B, C type) 0~200pF 12A or less Between measurement terminal and ground: DC500V 20MΩ or more
Between power terminal and ground: DC500V 20MΩ or more
Between power supply terminal and measurement terminal: DC500V 20MΩ or more
Between measurement terminal and ground: AC1,500V for 1 minute
Between power terminal and ground: AC1,500V for 1 minute
Between power supply terminal and measurement terminal: AC2,300V for 1 minute
Fixed at 0 38,400bps RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit 1 point (COM-K only) RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant Approximately 180g Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment 1 point No optional feature 2 Relay contact output, 1a contact At AC24V: 8VA or less
At DC24V: 220mA or less
Operation is not affected by power outages of 20msec or less AC/DC24V With reference input function UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE marking: Low Voltage Directive (LVD) EN61010-1
EMC Directive: EN61326-1
RCM: EN55011
0.1 seconds IP66 NEMA4X *However, only in the front direction when mounted on a panel
Capacitive level sensor/level meter RMC500-Part Number-RMC-500B3*A4N-NNN

RMC-500B3*A4N-NNN

Available upon quote -10~+55℃ Voltage output DC0~5V Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function No communication function Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action Data backup using non-volatile memory
Number of rewrites: 1 million times
Data storage retention period: Approximately 10 years
With 6 points (DO1~DO6) None (Shipped at shipping value) Linearity error ±0.1% of input span (B, C type) 0~200pF 12A or less Between measurement terminal and ground: DC500V 20MΩ or more
Between power terminal and ground: DC500V 20MΩ or more
Between power supply terminal and measurement terminal: DC500V 20MΩ or more
Between measurement terminal and ground: AC1,500V for 1 minute
Between power terminal and ground: AC1,500V for 1 minute
Between power supply terminal and measurement terminal: AC2,300V for 1 minute
Fixed at 0 38,400bps RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit 1 point (COM-K only) RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant Approximately 180g Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment 1 point No optional feature 2 Relay contact output, 1a contact At AC24V: 8VA or less
At DC24V: 220mA or less
Operation is not affected by power outages of 20msec or less AC/DC24V No reference input function UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE marking: Low Voltage Directive (LVD) EN61010-1
EMC Directive: EN61326-1
RCM: EN55011
0.1 seconds IP66 NEMA4X *However, only in the front direction when mounted on a panel
Capacitive level sensor/level meter RMC500-Part Number-RMC-500B3*A4N-1NN

RMC-500B3*A4N-1NN

Available upon quote -10~+55℃ Voltage output DC0~5V Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function No communication function Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action Data backup using non-volatile memory
Number of rewrites: 1 million times
Data storage retention period: Approximately 10 years
With 6 points (DO1~DO6) None (Shipped at shipping value) Linearity error ±0.1% of input span (B, C type) 0~200pF 12A or less Between measurement terminal and ground: DC500V 20MΩ or more
Between power terminal and ground: DC500V 20MΩ or more
Between power supply terminal and measurement terminal: DC500V 20MΩ or more
Between measurement terminal and ground: AC1,500V for 1 minute
Between power terminal and ground: AC1,500V for 1 minute
Between power supply terminal and measurement terminal: AC2,300V for 1 minute
Fixed at 0 38,400bps RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit 1 point (COM-K only) RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant Approximately 180g Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment 1 point No optional feature 2 Relay contact output, 1a contact At AC24V: 8VA or less
At DC24V: 220mA or less
Operation is not affected by power outages of 20msec or less AC/DC24V With reference input function UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE marking: Low Voltage Directive (LVD) EN61010-1
EMC Directive: EN61326-1
RCM: EN55011
0.1 seconds IP66 NEMA4X *However, only in the front direction when mounted on a panel
Capacitive level sensor/level meter RMC500-Part Number-RMC-500B3*A45-NNN

RMC-500B3*A45-NNN

Available upon quote -10~+55℃ Voltage output DC0~5V Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function RS-485 Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action Data backup using non-volatile memory
Number of rewrites: 1 million times
Data storage retention period: Approximately 10 years
With 6 points (DO1~DO6) None (Shipped at shipping value) Linearity error ±0.1% of input span (B, C type) 0~200pF 12A or less Between measurement terminal and ground: DC500V 20MΩ or more
Between power terminal and ground: DC500V 20MΩ or more
Between power supply terminal and measurement terminal: DC500V 20MΩ or more
Between measurement terminal and ground: AC1,500V for 1 minute
Between power terminal and ground: AC1,500V for 1 minute
Between power supply terminal and measurement terminal: AC2,300V for 1 minute
Fixed at 0 38,400bps RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit 1 point (COM-K only) RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant Approximately 180g Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment 1 point No optional feature 2 Relay contact output, 1a contact At AC24V: 8VA or less
At DC24V: 220mA or less
Operation is not affected by power outages of 20msec or less AC/DC24V No reference input function UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE marking: Low Voltage Directive (LVD) EN61010-1
EMC Directive: EN61326-1
RCM: EN55011
0.1 seconds IP66 NEMA4X *However, only in the front direction when mounted on a panel
Capacitive level sensor/level meter RMC500-Part Number-RMC-500B3*A45-1NN

RMC-500B3*A45-1NN

Available upon quote -10~+55℃ Voltage output DC0~5V Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function RS-485 Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action Data backup using non-volatile memory
Number of rewrites: 1 million times
Data storage retention period: Approximately 10 years
With 6 points (DO1~DO6) None (Shipped at shipping value) Linearity error ±0.1% of input span (B, C type) 0~200pF 12A or less Between measurement terminal and ground: DC500V 20MΩ or more
Between power terminal and ground: DC500V 20MΩ or more
Between power supply terminal and measurement terminal: DC500V 20MΩ or more
Between measurement terminal and ground: AC1,500V for 1 minute
Between power terminal and ground: AC1,500V for 1 minute
Between power supply terminal and measurement terminal: AC2,300V for 1 minute
Fixed at 0 38,400bps RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit 1 point (COM-K only) RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant Approximately 180g Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment 1 point No optional feature 2 Relay contact output, 1a contact At AC24V: 8VA or less
At DC24V: 220mA or less
Operation is not affected by power outages of 20msec or less AC/DC24V With reference input function UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE marking: Low Voltage Directive (LVD) EN61010-1
EMC Directive: EN61326-1
RCM: EN55011
0.1 seconds IP66 NEMA4X *However, only in the front direction when mounted on a panel
Capacitive level sensor/level meter RMC500-Part Number-RMC-500B3*A5N-NNN

RMC-500B3*A5N-NNN

Available upon quote -10~+55℃ Voltage output DC0~10V Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function No communication function Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action Data backup using non-volatile memory
Number of rewrites: 1 million times
Data storage retention period: Approximately 10 years
With 6 points (DO1~DO6) None (Shipped at shipping value) Linearity error ±0.1% of input span (B, C type) 0~200pF 12A or less Between measurement terminal and ground: DC500V 20MΩ or more
Between power terminal and ground: DC500V 20MΩ or more
Between power supply terminal and measurement terminal: DC500V 20MΩ or more
Between measurement terminal and ground: AC1,500V for 1 minute
Between power terminal and ground: AC1,500V for 1 minute
Between power supply terminal and measurement terminal: AC2,300V for 1 minute
Fixed at 0 38,400bps RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit 1 point (COM-K only) RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant Approximately 180g Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment 1 point No optional feature 2 Relay contact output, 1a contact At AC24V: 8VA or less
At DC24V: 220mA or less
Operation is not affected by power outages of 20msec or less AC/DC24V No reference input function UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE marking: Low Voltage Directive (LVD) EN61010-1
EMC Directive: EN61326-1
RCM: EN55011
0.1 seconds IP66 NEMA4X *However, only in the front direction when mounted on a panel
Capacitive level sensor/level meter RMC500-Part Number-RMC-500B3*A5N-1NN

RMC-500B3*A5N-1NN

Available upon quote -10~+55℃ Voltage output DC0~10V Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function No communication function Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action Data backup using non-volatile memory
Number of rewrites: 1 million times
Data storage retention period: Approximately 10 years
With 6 points (DO1~DO6) None (Shipped at shipping value) Linearity error ±0.1% of input span (B, C type) 0~200pF 12A or less Between measurement terminal and ground: DC500V 20MΩ or more
Between power terminal and ground: DC500V 20MΩ or more
Between power supply terminal and measurement terminal: DC500V 20MΩ or more
Between measurement terminal and ground: AC1,500V for 1 minute
Between power terminal and ground: AC1,500V for 1 minute
Between power supply terminal and measurement terminal: AC2,300V for 1 minute
Fixed at 0 38,400bps RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit 1 point (COM-K only) RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant Approximately 180g Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment 1 point No optional feature 2 Relay contact output, 1a contact At AC24V: 8VA or less
At DC24V: 220mA or less
Operation is not affected by power outages of 20msec or less AC/DC24V With reference input function UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE marking: Low Voltage Directive (LVD) EN61010-1
EMC Directive: EN61326-1
RCM: EN55011
0.1 seconds IP66 NEMA4X *However, only in the front direction when mounted on a panel

Click on the part number for more information about each product