Capacitive level sensor/level meter RMC500Handling Company
RKC INSTRUMENTCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply voltage | Waterproof and dustproof structure | Communication function | Mass | Insulation voltage | Insulation resistance | Inrush current (at maximum load) | Measurement input correction function | Power consumption | Safety standards | Factory settings (event function/communication protocol specification) | Output type | Contents of the output | Input accuracy | Input range | Number of input points | Power outage processing | Ambient temperature | Loader communication function Communication speed | Loader communication function Maximum number of connection points | Loader communication function protocol | Loader communication function Data format | Loader communication function Address setting | Reference input function | Data backup | Digital (alarm) output | Sampling period | Calibration function | Optional feature 2 | Analog transmission output (optional) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
RMC-500B3*ANN-NNN |
Available upon quote |
AC/DC24V |
IP66 NEMA4X *However, only in the front direction when mounted on a panel |
No communication function |
Approximately 180g |
Between measurement terminal and ground: AC1,500V for 1 minute |
Between measurement terminal and ground: DC500V 20MΩ or more |
12A or less |
Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment |
At AC24V: 8VA or less |
UL UL61010-1 |
None (Shipped at shipping value) |
Relay contact output, 1a contact |
Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Linearity error ±0.1% of input span (B, C type) |
0~200pF |
1 point |
Operation is not affected by power outages of 20msec or less |
-10~+55℃ |
38,400bps |
1 point (COM-K only) |
RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant |
RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit |
Fixed at 0 |
No reference input function |
Data backup using non-volatile memory |
With 6 points (DO1~DO6) |
0.1 seconds |
Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function |
No optional feature 2 |
No analog transmission output |
![]() |
RMC-500B3*ANN-1NN |
Available upon quote |
AC/DC24V |
IP66 NEMA4X *However, only in the front direction when mounted on a panel |
No communication function |
Approximately 180g |
Between measurement terminal and ground: AC1,500V for 1 minute |
Between measurement terminal and ground: DC500V 20MΩ or more |
12A or less |
Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment |
At AC24V: 8VA or less |
UL UL61010-1 |
None (Shipped at shipping value) |
Relay contact output, 1a contact |
Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Linearity error ±0.1% of input span (B, C type) |
0~200pF |
1 point |
Operation is not affected by power outages of 20msec or less |
-10~+55℃ |
38,400bps |
1 point (COM-K only) |
RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant |
RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit |
Fixed at 0 |
With reference input function |
Data backup using non-volatile memory |
With 6 points (DO1~DO6) |
0.1 seconds |
Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function |
No optional feature 2 |
No analog transmission output |
![]() |
RMC-500B3*AN5-NNN |
Available upon quote |
AC/DC24V |
IP66 NEMA4X *However, only in the front direction when mounted on a panel |
RS-485 |
Approximately 180g |
Between measurement terminal and ground: AC1,500V for 1 minute |
Between measurement terminal and ground: DC500V 20MΩ or more |
12A or less |
Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment |
At AC24V: 8VA or less |
UL UL61010-1 |
None (Shipped at shipping value) |
Relay contact output, 1a contact |
Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Linearity error ±0.1% of input span (B, C type) |
0~200pF |
1 point |
Operation is not affected by power outages of 20msec or less |
-10~+55℃ |
38,400bps |
1 point (COM-K only) |
RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant |
RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit |
Fixed at 0 |
No reference input function |
Data backup using non-volatile memory |
With 6 points (DO1~DO6) |
0.1 seconds |
Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function |
No optional feature 2 |
No analog transmission output |
![]() |
RMC-500B3*AN5-1NN |
Available upon quote |
AC/DC24V |
IP66 NEMA4X *However, only in the front direction when mounted on a panel |
RS-485 |
Approximately 180g |
Between measurement terminal and ground: AC1,500V for 1 minute |
Between measurement terminal and ground: DC500V 20MΩ or more |
12A or less |
Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment |
At AC24V: 8VA or less |
UL UL61010-1 |
None (Shipped at shipping value) |
Relay contact output, 1a contact |
Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Linearity error ±0.1% of input span (B, C type) |
0~200pF |
1 point |
Operation is not affected by power outages of 20msec or less |
-10~+55℃ |
38,400bps |
1 point (COM-K only) |
RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant |
RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit |
Fixed at 0 |
With reference input function |
Data backup using non-volatile memory |
With 6 points (DO1~DO6) |
0.1 seconds |
Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function |
No optional feature 2 |
No analog transmission output |
![]() |
RMC-500B3*A4N-NNN |
Available upon quote |
AC/DC24V |
IP66 NEMA4X *However, only in the front direction when mounted on a panel |
No communication function |
Approximately 180g |
Between measurement terminal and ground: AC1,500V for 1 minute |
Between measurement terminal and ground: DC500V 20MΩ or more |
12A or less |
Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment |
At AC24V: 8VA or less |
UL UL61010-1 |
None (Shipped at shipping value) |
Relay contact output, 1a contact |
Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Linearity error ±0.1% of input span (B, C type) |
0~200pF |
1 point |
Operation is not affected by power outages of 20msec or less |
-10~+55℃ |
38,400bps |
1 point (COM-K only) |
RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant |
RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit |
Fixed at 0 |
No reference input function |
Data backup using non-volatile memory |
With 6 points (DO1~DO6) |
0.1 seconds |
Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function |
No optional feature 2 |
Voltage output DC0~5V |
![]() |
RMC-500B3*A4N-1NN |
Available upon quote |
AC/DC24V |
IP66 NEMA4X *However, only in the front direction when mounted on a panel |
No communication function |
Approximately 180g |
Between measurement terminal and ground: AC1,500V for 1 minute |
Between measurement terminal and ground: DC500V 20MΩ or more |
12A or less |
Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment |
At AC24V: 8VA or less |
UL UL61010-1 |
None (Shipped at shipping value) |
Relay contact output, 1a contact |
Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Linearity error ±0.1% of input span (B, C type) |
0~200pF |
1 point |
Operation is not affected by power outages of 20msec or less |
-10~+55℃ |
38,400bps |
1 point (COM-K only) |
RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant |
RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit |
Fixed at 0 |
With reference input function |
Data backup using non-volatile memory |
With 6 points (DO1~DO6) |
0.1 seconds |
Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function |
No optional feature 2 |
Voltage output DC0~5V |
![]() |
RMC-500B3*A45-NNN |
Available upon quote |
AC/DC24V |
IP66 NEMA4X *However, only in the front direction when mounted on a panel |
RS-485 |
Approximately 180g |
Between measurement terminal and ground: AC1,500V for 1 minute |
Between measurement terminal and ground: DC500V 20MΩ or more |
12A or less |
Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment |
At AC24V: 8VA or less |
UL UL61010-1 |
None (Shipped at shipping value) |
Relay contact output, 1a contact |
Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Linearity error ±0.1% of input span (B, C type) |
0~200pF |
1 point |
Operation is not affected by power outages of 20msec or less |
-10~+55℃ |
38,400bps |
1 point (COM-K only) |
RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant |
RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit |
Fixed at 0 |
No reference input function |
Data backup using non-volatile memory |
With 6 points (DO1~DO6) |
0.1 seconds |
Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function |
No optional feature 2 |
Voltage output DC0~5V |
![]() |
RMC-500B3*A45-1NN |
Available upon quote |
AC/DC24V |
IP66 NEMA4X *However, only in the front direction when mounted on a panel |
RS-485 |
Approximately 180g |
Between measurement terminal and ground: AC1,500V for 1 minute |
Between measurement terminal and ground: DC500V 20MΩ or more |
12A or less |
Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment |
At AC24V: 8VA or less |
UL UL61010-1 |
None (Shipped at shipping value) |
Relay contact output, 1a contact |
Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Linearity error ±0.1% of input span (B, C type) |
0~200pF |
1 point |
Operation is not affected by power outages of 20msec or less |
-10~+55℃ |
38,400bps |
1 point (COM-K only) |
RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant |
RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit |
Fixed at 0 |
With reference input function |
Data backup using non-volatile memory |
With 6 points (DO1~DO6) |
0.1 seconds |
Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function |
No optional feature 2 |
Voltage output DC0~5V |
![]() |
RMC-500B3*A5N-NNN |
Available upon quote |
AC/DC24V |
IP66 NEMA4X *However, only in the front direction when mounted on a panel |
No communication function |
Approximately 180g |
Between measurement terminal and ground: AC1,500V for 1 minute |
Between measurement terminal and ground: DC500V 20MΩ or more |
12A or less |
Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment |
At AC24V: 8VA or less |
UL UL61010-1 |
None (Shipped at shipping value) |
Relay contact output, 1a contact |
Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Linearity error ±0.1% of input span (B, C type) |
0~200pF |
1 point |
Operation is not affected by power outages of 20msec or less |
-10~+55℃ |
38,400bps |
1 point (COM-K only) |
RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant |
RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit |
Fixed at 0 |
No reference input function |
Data backup using non-volatile memory |
With 6 points (DO1~DO6) |
0.1 seconds |
Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function |
No optional feature 2 |
Voltage output DC0~10V |
![]() |
RMC-500B3*A5N-1NN |
Available upon quote |
AC/DC24V |
IP66 NEMA4X *However, only in the front direction when mounted on a panel |
No communication function |
Approximately 180g |
Between measurement terminal and ground: AC1,500V for 1 minute |
Between measurement terminal and ground: DC500V 20MΩ or more |
12A or less |
Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment |
At AC24V: 8VA or less |
UL UL61010-1 |
None (Shipped at shipping value) |
Relay contact output, 1a contact |
Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Linearity error ±0.1% of input span (B, C type) |
0~200pF |
1 point |
Operation is not affected by power outages of 20msec or less |
-10~+55℃ |
38,400bps |
1 point (COM-K only) |
RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant |
RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit |
Fixed at 0 |
With reference input function |
Data backup using non-volatile memory |
With 6 points (DO1~DO6) |
0.1 seconds |
Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function |
No optional feature 2 |
Voltage output DC0~10V |