Product
Capacitive level sensor/level meter RMC500Handling Company
RKC INSTRUMENTCategories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Ambient temperature | Analog transmission output (optional) | Calibration function | Communication function | Contents of the output | Data backup | Digital (alarm) output | Factory settings (event function/communication protocol specification) | Input accuracy | Input range | Inrush current (at maximum load) | Insulation resistance | Insulation voltage | Loader communication function Address setting | Loader communication function Communication speed | Loader communication function Data format | Loader communication function Maximum number of connection points | Loader communication function protocol | Mass | Measurement input correction function | Number of input points | Optional feature 2 | Output type | Power consumption | Power outage processing | Power supply voltage | Reference input function | Safety standards | Sampling period | Waterproof and dustproof structure |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RMC-500B3*ANN-NNN |
Available upon quote | -10~+55℃ | No analog transmission output | Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function | No communication function | Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Data backup using non-volatile memory Number of rewrites: 1 million times Data storage retention period: Approximately 10 years |
With 6 points (DO1~DO6) | None (Shipped at shipping value) | Linearity error ±0.1% of input span (B, C type) | 0~200pF | 12A or less |
Between measurement terminal and ground: DC500V 20MΩ or more Between power terminal and ground: DC500V 20MΩ or more Between power supply terminal and measurement terminal: DC500V 20MΩ or more |
Between measurement terminal and ground: AC1,500V for 1 minute Between power terminal and ground: AC1,500V for 1 minute Between power supply terminal and measurement terminal: AC2,300V for 1 minute |
Fixed at 0 | 38,400bps | RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit | 1 point (COM-K only) | RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant | Approximately 180g | Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment | 1 point | No optional feature 2 | Relay contact output, 1a contact |
At AC24V: 8VA or less At DC24V: 220mA or less |
Operation is not affected by power outages of 20msec or less | AC/DC24V | No reference input function |
UL UL61010-1 cUL CAN/CSA-22.2 NO.61010-1 CE marking: Low Voltage Directive (LVD) EN61010-1 EMC Directive: EN61326-1 RCM: EN55011 |
0.1 seconds | IP66 NEMA4X *However, only in the front direction when mounted on a panel | |
RMC-500B3*ANN-1NN |
Available upon quote | -10~+55℃ | No analog transmission output | Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function | No communication function | Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Data backup using non-volatile memory Number of rewrites: 1 million times Data storage retention period: Approximately 10 years |
With 6 points (DO1~DO6) | None (Shipped at shipping value) | Linearity error ±0.1% of input span (B, C type) | 0~200pF | 12A or less |
Between measurement terminal and ground: DC500V 20MΩ or more Between power terminal and ground: DC500V 20MΩ or more Between power supply terminal and measurement terminal: DC500V 20MΩ or more |
Between measurement terminal and ground: AC1,500V for 1 minute Between power terminal and ground: AC1,500V for 1 minute Between power supply terminal and measurement terminal: AC2,300V for 1 minute |
Fixed at 0 | 38,400bps | RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit | 1 point (COM-K only) | RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant | Approximately 180g | Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment | 1 point | No optional feature 2 | Relay contact output, 1a contact |
At AC24V: 8VA or less At DC24V: 220mA or less |
Operation is not affected by power outages of 20msec or less | AC/DC24V | With reference input function |
UL UL61010-1 cUL CAN/CSA-22.2 NO.61010-1 CE marking: Low Voltage Directive (LVD) EN61010-1 EMC Directive: EN61326-1 RCM: EN55011 |
0.1 seconds | IP66 NEMA4X *However, only in the front direction when mounted on a panel | |
RMC-500B3*AN5-NNN |
Available upon quote | -10~+55℃ | No analog transmission output | Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function | RS-485 | Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Data backup using non-volatile memory Number of rewrites: 1 million times Data storage retention period: Approximately 10 years |
With 6 points (DO1~DO6) | None (Shipped at shipping value) | Linearity error ±0.1% of input span (B, C type) | 0~200pF | 12A or less |
Between measurement terminal and ground: DC500V 20MΩ or more Between power terminal and ground: DC500V 20MΩ or more Between power supply terminal and measurement terminal: DC500V 20MΩ or more |
Between measurement terminal and ground: AC1,500V for 1 minute Between power terminal and ground: AC1,500V for 1 minute Between power supply terminal and measurement terminal: AC2,300V for 1 minute |
Fixed at 0 | 38,400bps | RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit | 1 point (COM-K only) | RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant | Approximately 180g | Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment | 1 point | No optional feature 2 | Relay contact output, 1a contact |
At AC24V: 8VA or less At DC24V: 220mA or less |
Operation is not affected by power outages of 20msec or less | AC/DC24V | No reference input function |
UL UL61010-1 cUL CAN/CSA-22.2 NO.61010-1 CE marking: Low Voltage Directive (LVD) EN61010-1 EMC Directive: EN61326-1 RCM: EN55011 |
0.1 seconds | IP66 NEMA4X *However, only in the front direction when mounted on a panel | |
RMC-500B3*AN5-1NN |
Available upon quote | -10~+55℃ | No analog transmission output | Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function | RS-485 | Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Data backup using non-volatile memory Number of rewrites: 1 million times Data storage retention period: Approximately 10 years |
With 6 points (DO1~DO6) | None (Shipped at shipping value) | Linearity error ±0.1% of input span (B, C type) | 0~200pF | 12A or less |
Between measurement terminal and ground: DC500V 20MΩ or more Between power terminal and ground: DC500V 20MΩ or more Between power supply terminal and measurement terminal: DC500V 20MΩ or more |
Between measurement terminal and ground: AC1,500V for 1 minute Between power terminal and ground: AC1,500V for 1 minute Between power supply terminal and measurement terminal: AC2,300V for 1 minute |
Fixed at 0 | 38,400bps | RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit | 1 point (COM-K only) | RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant | Approximately 180g | Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment | 1 point | No optional feature 2 | Relay contact output, 1a contact |
At AC24V: 8VA or less At DC24V: 220mA or less |
Operation is not affected by power outages of 20msec or less | AC/DC24V | With reference input function |
UL UL61010-1 cUL CAN/CSA-22.2 NO.61010-1 CE marking: Low Voltage Directive (LVD) EN61010-1 EMC Directive: EN61326-1 RCM: EN55011 |
0.1 seconds | IP66 NEMA4X *However, only in the front direction when mounted on a panel | |
RMC-500B3*A4N-NNN |
Available upon quote | -10~+55℃ | Voltage output DC0~5V | Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function | No communication function | Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Data backup using non-volatile memory Number of rewrites: 1 million times Data storage retention period: Approximately 10 years |
With 6 points (DO1~DO6) | None (Shipped at shipping value) | Linearity error ±0.1% of input span (B, C type) | 0~200pF | 12A or less |
Between measurement terminal and ground: DC500V 20MΩ or more Between power terminal and ground: DC500V 20MΩ or more Between power supply terminal and measurement terminal: DC500V 20MΩ or more |
Between measurement terminal and ground: AC1,500V for 1 minute Between power terminal and ground: AC1,500V for 1 minute Between power supply terminal and measurement terminal: AC2,300V for 1 minute |
Fixed at 0 | 38,400bps | RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit | 1 point (COM-K only) | RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant | Approximately 180g | Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment | 1 point | No optional feature 2 | Relay contact output, 1a contact |
At AC24V: 8VA or less At DC24V: 220mA or less |
Operation is not affected by power outages of 20msec or less | AC/DC24V | No reference input function |
UL UL61010-1 cUL CAN/CSA-22.2 NO.61010-1 CE marking: Low Voltage Directive (LVD) EN61010-1 EMC Directive: EN61326-1 RCM: EN55011 |
0.1 seconds | IP66 NEMA4X *However, only in the front direction when mounted on a panel | |
RMC-500B3*A4N-1NN |
Available upon quote | -10~+55℃ | Voltage output DC0~5V | Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function | No communication function | Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Data backup using non-volatile memory Number of rewrites: 1 million times Data storage retention period: Approximately 10 years |
With 6 points (DO1~DO6) | None (Shipped at shipping value) | Linearity error ±0.1% of input span (B, C type) | 0~200pF | 12A or less |
Between measurement terminal and ground: DC500V 20MΩ or more Between power terminal and ground: DC500V 20MΩ or more Between power supply terminal and measurement terminal: DC500V 20MΩ or more |
Between measurement terminal and ground: AC1,500V for 1 minute Between power terminal and ground: AC1,500V for 1 minute Between power supply terminal and measurement terminal: AC2,300V for 1 minute |
Fixed at 0 | 38,400bps | RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit | 1 point (COM-K only) | RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant | Approximately 180g | Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment | 1 point | No optional feature 2 | Relay contact output, 1a contact |
At AC24V: 8VA or less At DC24V: 220mA or less |
Operation is not affected by power outages of 20msec or less | AC/DC24V | With reference input function |
UL UL61010-1 cUL CAN/CSA-22.2 NO.61010-1 CE marking: Low Voltage Directive (LVD) EN61010-1 EMC Directive: EN61326-1 RCM: EN55011 |
0.1 seconds | IP66 NEMA4X *However, only in the front direction when mounted on a panel | |
RMC-500B3*A45-NNN |
Available upon quote | -10~+55℃ | Voltage output DC0~5V | Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function | RS-485 | Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Data backup using non-volatile memory Number of rewrites: 1 million times Data storage retention period: Approximately 10 years |
With 6 points (DO1~DO6) | None (Shipped at shipping value) | Linearity error ±0.1% of input span (B, C type) | 0~200pF | 12A or less |
Between measurement terminal and ground: DC500V 20MΩ or more Between power terminal and ground: DC500V 20MΩ or more Between power supply terminal and measurement terminal: DC500V 20MΩ or more |
Between measurement terminal and ground: AC1,500V for 1 minute Between power terminal and ground: AC1,500V for 1 minute Between power supply terminal and measurement terminal: AC2,300V for 1 minute |
Fixed at 0 | 38,400bps | RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit | 1 point (COM-K only) | RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant | Approximately 180g | Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment | 1 point | No optional feature 2 | Relay contact output, 1a contact |
At AC24V: 8VA or less At DC24V: 220mA or less |
Operation is not affected by power outages of 20msec or less | AC/DC24V | No reference input function |
UL UL61010-1 cUL CAN/CSA-22.2 NO.61010-1 CE marking: Low Voltage Directive (LVD) EN61010-1 EMC Directive: EN61326-1 RCM: EN55011 |
0.1 seconds | IP66 NEMA4X *However, only in the front direction when mounted on a panel | |
RMC-500B3*A45-1NN |
Available upon quote | -10~+55℃ | Voltage output DC0~5V | Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function | RS-485 | Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Data backup using non-volatile memory Number of rewrites: 1 million times Data storage retention period: Approximately 10 years |
With 6 points (DO1~DO6) | None (Shipped at shipping value) | Linearity error ±0.1% of input span (B, C type) | 0~200pF | 12A or less |
Between measurement terminal and ground: DC500V 20MΩ or more Between power terminal and ground: DC500V 20MΩ or more Between power supply terminal and measurement terminal: DC500V 20MΩ or more |
Between measurement terminal and ground: AC1,500V for 1 minute Between power terminal and ground: AC1,500V for 1 minute Between power supply terminal and measurement terminal: AC2,300V for 1 minute |
Fixed at 0 | 38,400bps | RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit | 1 point (COM-K only) | RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant | Approximately 180g | Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment | 1 point | No optional feature 2 | Relay contact output, 1a contact |
At AC24V: 8VA or less At DC24V: 220mA or less |
Operation is not affected by power outages of 20msec or less | AC/DC24V | With reference input function |
UL UL61010-1 cUL CAN/CSA-22.2 NO.61010-1 CE marking: Low Voltage Directive (LVD) EN61010-1 EMC Directive: EN61326-1 RCM: EN55011 |
0.1 seconds | IP66 NEMA4X *However, only in the front direction when mounted on a panel | |
RMC-500B3*A5N-NNN |
Available upon quote | -10~+55℃ | Voltage output DC0~10V | Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function | No communication function | Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Data backup using non-volatile memory Number of rewrites: 1 million times Data storage retention period: Approximately 10 years |
With 6 points (DO1~DO6) | None (Shipped at shipping value) | Linearity error ±0.1% of input span (B, C type) | 0~200pF | 12A or less |
Between measurement terminal and ground: DC500V 20MΩ or more Between power terminal and ground: DC500V 20MΩ or more Between power supply terminal and measurement terminal: DC500V 20MΩ or more |
Between measurement terminal and ground: AC1,500V for 1 minute Between power terminal and ground: AC1,500V for 1 minute Between power supply terminal and measurement terminal: AC2,300V for 1 minute |
Fixed at 0 | 38,400bps | RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit | 1 point (COM-K only) | RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant | Approximately 180g | Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment | 1 point | No optional feature 2 | Relay contact output, 1a contact |
At AC24V: 8VA or less At DC24V: 220mA or less |
Operation is not affected by power outages of 20msec or less | AC/DC24V | No reference input function |
UL UL61010-1 cUL CAN/CSA-22.2 NO.61010-1 CE marking: Low Voltage Directive (LVD) EN61010-1 EMC Directive: EN61326-1 RCM: EN55011 |
0.1 seconds | IP66 NEMA4X *However, only in the front direction when mounted on a panel | |
RMC-500B3*A5N-1NN |
Available upon quote | -10~+55℃ | Voltage output DC0~10V | Actual liquid adjustment function, PV bias function, advance adjustment function (theoretical value calibration function), linearization function | No communication function | Upper limit input value alarm, lower limit input value alarm, FAIL (possible only for DO6) *Can be selected with or without standby action |
Data backup using non-volatile memory Number of rewrites: 1 million times Data storage retention period: Approximately 10 years |
With 6 points (DO1~DO6) | None (Shipped at shipping value) | Linearity error ±0.1% of input span (B, C type) | 0~200pF | 12A or less |
Between measurement terminal and ground: DC500V 20MΩ or more Between power terminal and ground: DC500V 20MΩ or more Between power supply terminal and measurement terminal: DC500V 20MΩ or more |
Between measurement terminal and ground: AC1,500V for 1 minute Between power terminal and ground: AC1,500V for 1 minute Between power supply terminal and measurement terminal: AC2,300V for 1 minute |
Fixed at 0 | 38,400bps | RKC standard: 1 start bit, 8 data bits, no parity bit, 1 stop bit | 1 point (COM-K only) | RKC standard ANSIX3.28-1976 subcategory 2.5A4 compliant | Approximately 180g | Zero point correction (auto zero/manual setting), span point correction (auto span/manual setting), digital filter, EMPTY adjustment | 1 point | No optional feature 2 | Relay contact output, 1a contact |
At AC24V: 8VA or less At DC24V: 220mA or less |
Operation is not affected by power outages of 20msec or less | AC/DC24V | With reference input function |
UL UL61010-1 cUL CAN/CSA-22.2 NO.61010-1 CE marking: Low Voltage Directive (LVD) EN61010-1 EMC Directive: EN61326-1 RCM: EN55011 |
0.1 seconds | IP66 NEMA4X *However, only in the front direction when mounted on a panel |
Click on the part number for more information about each product