Image | Part Number | Price (excluding tax) | Power supply voltage (rated) | Voltage accuracy | Adaptive sensor | Mass | Permissible ambient humidity | Permissible ambient temperature | Setting accuracy | Withstand voltage | Insulation resistance | Power consumption | Applied voltage | Number of output points | Output converter | Input range | Operation when input is disconnected | Input impedance | Usage atmosphere | Zero point adjustment range | Zero point temperature drift | Sensor power supply temperature drift | Gain setting range | Gain temperature drift | Optional features | Other conditions |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PCT-300N-2N |
Available upon quote |
AC100~240V |
+0.1~-0.4% |
Strain gauge type sensor |
Approximately 290g |
45~85%RH (no condensation) |
0~50℃ |
±0.2% of span/℃ |
Between input/output and power supply: AC2,300V for 1 minute |
Between input/output and power supply 500V DC 100MΩ or more |
7.5VA or less (at AC100V) 12.5VA or less (at AC240V) |
DC10V |
For 2 outputs (DC0~10V, DC0~10mV) |
Standard specifications |
0~19.99mV |
Upscale (same when sensor power supply is disconnected) |
1MΩ or more |
No corrosive or flammable gases, and no heavy dust. |
±7mV (input conversion) |
±0.02%/℃ of span |
30ppm/℃ or less |
An input of 10.00~19.99mV can be rated (10V, etc.). |
100ppm/℃ or less |
No options |
No external noise and no direct vibration or impact. |
|
PCT-300N-2G |
Available upon quote |
AC100~240V |
+0.1~-0.4% |
Strain gauge type sensor |
Approximately 290g |
45~85%RH (no condensation) |
0~50℃ |
±0.2% of span/℃ |
Between input/output and power supply: AC2,300V for 1 minute |
Between input/output and power supply 500V DC 100MΩ or more |
7.5VA or less (at AC100V) 12.5VA or less (at AC240V) |
DC10V |
For 2 outputs (DC0~10V, DC0~10mV) |
Standard specifications |
0~19.99mV |
Upscale (same when sensor power supply is disconnected) |
1MΩ or more |
No corrosive or flammable gases, and no heavy dust. |
±7mV (input conversion) |
±0.02%/℃ of span |
30ppm/℃ or less |
An input of 10.00~19.99mV can be rated (10V, etc.). |
100ppm/℃ or less |
With gain selector switch |
No external noise and no direct vibration or impact. |
|
PCT-300N-2L |
Available upon quote |
AC100~240V |
+0.1~-0.4% |
Strain gauge type sensor |
Approximately 290g |
45~85%RH (no condensation) |
0~50℃ |
±0.2% of span/℃ |
Between input/output and power supply: AC2,300V for 1 minute |
Between input/output and power supply 500V DC 100MΩ or more |
7.5VA or less (at AC100V) 12.5VA or less (at AC240V) |
DC10V |
For 2 outputs (DC0~10V, DC0~10mV) |
Standard specifications |
0~19.99mV |
Upscale (same when sensor power supply is disconnected) |
1MΩ or more |
No corrosive or flammable gases, and no heavy dust. |
±7mV (input conversion) |
±0.02%/℃ of span |
30ppm/℃ or less |
An input of 10.00~19.99mV can be rated (10V, etc.). |
100ppm/℃ or less |
With linearization function (combined with CZ-200P, total accuracy is 0.5%FS) |
No external noise and no direct vibration or impact. |
|
PCT-300N-3N |
Available upon quote |
AC100~240V |
+0.1~-0.4% |
Strain gauge type sensor |
Approximately 290g |
45~85%RH (no condensation) |
0~50℃ |
±0.2% of span/℃ |
Between input/output and power supply: AC2,300V for 1 minute |
Between input/output and power supply 500V DC 100MΩ or more |
7.5VA or less (at AC100V) 12.5VA or less (at AC240V) |
DC10V |
For 3 outputs (DC0~10V, DC0~10mV, DC1~5V) |
Standard specifications |
0~19.99mV |
Upscale (same when sensor power supply is disconnected) |
1MΩ or more |
No corrosive or flammable gases, and no heavy dust. |
±7mV (input conversion) |
±0.02%/℃ of span |
30ppm/℃ or less |
An input of 10.00~19.99mV can be rated (10V, etc.). |
100ppm/℃ or less |
No options |
No external noise and no direct vibration or impact. |
|
PCT-300N-3G |
Available upon quote |
AC100~240V |
+0.1~-0.4% |
Strain gauge type sensor |
Approximately 290g |
45~85%RH (no condensation) |
0~50℃ |
±0.2% of span/℃ |
Between input/output and power supply: AC2,300V for 1 minute |
Between input/output and power supply 500V DC 100MΩ or more |
7.5VA or less (at AC100V) 12.5VA or less (at AC240V) |
DC10V |
For 3 outputs (DC0~10V, DC0~10mV, DC1~5V) |
Standard specifications |
0~19.99mV |
Upscale (same when sensor power supply is disconnected) |
1MΩ or more |
No corrosive or flammable gases, and no heavy dust. |
±7mV (input conversion) |
±0.02%/℃ of span |
30ppm/℃ or less |
An input of 10.00~19.99mV can be rated (10V, etc.). |
100ppm/℃ or less |
With gain selector switch |
No external noise and no direct vibration or impact. |
|
PCT-300N-3L |
Available upon quote |
AC100~240V |
+0.1~-0.4% |
Strain gauge type sensor |
Approximately 290g |
45~85%RH (no condensation) |
0~50℃ |
±0.2% of span/℃ |
Between input/output and power supply: AC2,300V for 1 minute |
Between input/output and power supply 500V DC 100MΩ or more |
7.5VA or less (at AC100V) 12.5VA or less (at AC240V) |
DC10V |
For 3 outputs (DC0~10V, DC0~10mV, DC1~5V) |
Standard specifications |
0~19.99mV |
Upscale (same when sensor power supply is disconnected) |
1MΩ or more |
No corrosive or flammable gases, and no heavy dust. |
±7mV (input conversion) |
±0.02%/℃ of span |
30ppm/℃ or less |
An input of 10.00~19.99mV can be rated (10V, etc.). |
100ppm/℃ or less |
With linearization function (combined with CZ-200P, total accuracy is 0.5%FS) |
No external noise and no direct vibration or impact. |
|
PCT-300N-4N |
Available upon quote |
AC100~240V |
+0.1~-0.4% |
Strain gauge type sensor |
Approximately 290g |
45~85%RH (no condensation) |
0~50℃ |
±0.2% of span/℃ |
Between input/output and power supply: AC2,300V for 1 minute |
Between input/output and power supply 500V DC 100MΩ or more |
7.5VA or less (at AC100V) 12.5VA or less (at AC240V) |
DC10V |
For 4 outputs (DC0~10V, DC0~10mV, DC1~5V, DC4~20mA) |
Standard specifications |
0~19.99mV |
Upscale (same when sensor power supply is disconnected) |
1MΩ or more |
No corrosive or flammable gases, and no heavy dust. |
±7mV (input conversion) |
±0.02%/℃ of span |
30ppm/℃ or less |
An input of 10.00~19.99mV can be rated (10V, etc.). |
100ppm/℃ or less |
No options |
No external noise and no direct vibration or impact. |
|
PCT-300N-4G |
Available upon quote |
AC100~240V |
+0.1~-0.4% |
Strain gauge type sensor |
Approximately 290g |
45~85%RH (no condensation) |
0~50℃ |
±0.2% of span/℃ |
Between input/output and power supply: AC2,300V for 1 minute |
Between input/output and power supply 500V DC 100MΩ or more |
7.5VA or less (at AC100V) 12.5VA or less (at AC240V) |
DC10V |
For 4 outputs (DC0~10V, DC0~10mV, DC1~5V, DC4~20mA) |
Standard specifications |
0~19.99mV |
Upscale (same when sensor power supply is disconnected) |
1MΩ or more |
No corrosive or flammable gases, and no heavy dust. |
±7mV (input conversion) |
±0.02%/℃ of span |
30ppm/℃ or less |
An input of 10.00~19.99mV can be rated (10V, etc.). |
100ppm/℃ or less |
With gain selector switch |
No external noise and no direct vibration or impact. |
|
PCT-300N-4L |
Available upon quote |
AC100~240V |
+0.1~-0.4% |
Strain gauge type sensor |
Approximately 290g |
45~85%RH (no condensation) |
0~50℃ |
±0.2% of span/℃ |
Between input/output and power supply: AC2,300V for 1 minute |
Between input/output and power supply 500V DC 100MΩ or more |
7.5VA or less (at AC100V) 12.5VA or less (at AC240V) |
DC10V |
For 4 outputs (DC0~10V, DC0~10mV, DC1~5V, DC4~20mA) |
Standard specifications |
0~19.99mV |
Upscale (same when sensor power supply is disconnected) |
1MΩ or more |
No corrosive or flammable gases, and no heavy dust. |
±7mV (input conversion) |
±0.02%/℃ of span |
30ppm/℃ or less |
An input of 10.00~19.99mV can be rated (10V, etc.). |
100ppm/℃ or less |
With linearization function (combined with CZ-200P, total accuracy is 0.5%FS) |
No external noise and no direct vibration or impact. |
|
PCT-300E-2N |
Available upon quote |
AC100~240V |
+0.1~-0.4% |
Strain gauge type sensor |
Approximately 290g |
45~85%RH (no condensation) |
0~50℃ |
±0.2% of span/℃ |
Between input/output and power supply: AC2,300V for 1 minute |
Between input/output and power supply 500V DC 100MΩ or more |
7.5VA or less (at AC100V) 12.5VA or less (at AC240V) |
DC8.2V |
For 2 outputs (DC0~10V, DC0~10mV) |
Intrinsically safe explosion-proof specification |
0~11.6mV *Excluding zero point adjustment bias |
Upscale (same when sensor power supply is disconnected) |
1MΩ or more |
No corrosive or flammable gases, and no heavy dust. |
±6mV (input conversion) |
±0.02%/℃ of span |
30ppm/℃ or less |
5.80~11.60mV input can be rated (10V etc.). |
100ppm/℃ or less |
No options |
No external noise and no direct vibration or impact. |