About This Product

■Large and clear display Large LED display with excellent visibility even from a distance. ■Maximum 4-point alarm function (optional) Upper or lower limit input value alarms can be assigned to four outputs. *It can also be set with a standby function. *Analog measurement output can be selected instead of third alarm output. ■Communication function (optional) Communication function (RS-485) allows multi-drop connection of up to 31 units. *Other product numbers are available.

  • Product

    Digital indicator AE500

Share this product


170+ people viewing

Last viewed: 6 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Digital indicator AE500

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Alarm 1 type Alarm 2 type Alarm 3 type/analog output Alarm 4 type/LED drive power supply for switch Applicable standards Body color Communication function Effect of external resistance Effect of input lead resistance Effects of power outage Input impedance Input/range Insulation resistance Measurement accuracy Memory backup Operation during input short circuit Operation when input is disconnected Other conditions PV bias Permissible ambient humidity Permissible ambient temperature Power consumption Power supply voltage Sampling period Usage atmosphere Waterproof dustproof Weight and dimensions Withstand voltage
Digital indicator AE500-Part Number-AE500K01-3*NNNN-NN/N

AE500K01-3*NNNN-NN/N

Available upon quote No alarm function No alarm function No function No function ・CE marking compliant
・Compliant with UL/cUL standards
・RCM mark compliant
White tone No communication function Approx. 0.2μV/Ω (Thermocouple input) Approximately 0.01 [%/Ω] of reading value (resistance temperature detector input)
*Maximum within 10Ω per wire
Power outages of 20msec or less will not affect operation.
*Any further power outage will result in the initial state.
Approximately 1MΩ K (JIS/IEC) 0~200℃ Between measurement terminal and ground DC 500V 20MΩ or more ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (approximately 10 years) Downscale (RTD input)
*Alarm output is ON
Upscale No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
When inputting temperature: -1,999~9,999℃ or -199.9~999.9℃ 45~85%RH 0~50℃ AC24V specifications: max. 5VA
DC24V specification: max. 160mA
AC/DC 24V 0.5 seconds No corrosive or flammable gases, and no heavy dust. No waterproof/dustproof structure
Approximately 250g, 48X96X100mm (length x width x depth) Between measurement terminal and ground: AC 1,000V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicator AE500-Part Number-AE500K01-3*NNNN-NN/A

AE500K01-3*NNNN-NN/A

Available upon quote No alarm function No alarm function No function No function ・CE marking compliant
・Compliant with UL/cUL standards
・RCM mark compliant
Black tone No communication function Approx. 0.2μV/Ω (Thermocouple input) Approximately 0.01 [%/Ω] of reading value (resistance temperature detector input)
*Maximum within 10Ω per wire
Power outages of 20msec or less will not affect operation.
*Any further power outage will result in the initial state.
Approximately 1MΩ K (JIS/IEC) 0~200℃ Between measurement terminal and ground DC 500V 20MΩ or more ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (approximately 10 years) Downscale (RTD input)
*Alarm output is ON
Upscale No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
When inputting temperature: -1,999~9,999℃ or -199.9~999.9℃ 45~85%RH 0~50℃ AC24V specifications: max. 5VA
DC24V specification: max. 160mA
AC/DC 24V 0.5 seconds No corrosive or flammable gases, and no heavy dust. No waterproof/dustproof structure
Approximately 250g, 48X96X100mm (length x width x depth) Between measurement terminal and ground: AC 1,000V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicator AE500-Part Number-AE500K01-3*NNNN-N1/N

AE500K01-3*NNNN-N1/N

Available upon quote No alarm function No alarm function No function No function ・CE marking compliant
・Compliant with UL/cUL standards
・RCM mark compliant
White tone No communication function Approx. 0.2μV/Ω (Thermocouple input) Approximately 0.01 [%/Ω] of reading value (resistance temperature detector input)
*Maximum within 10Ω per wire
Power outages of 20msec or less will not affect operation.
*Any further power outage will result in the initial state.
Approximately 1MΩ K (JIS/IEC) 0~200℃ Between measurement terminal and ground DC 500V 20MΩ or more ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (approximately 10 years) Downscale (RTD input)
*Alarm output is ON
Upscale No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
When inputting temperature: -1,999~9,999℃ or -199.9~999.9℃ 45~85%RH 0~50℃ AC24V specifications: max. 5VA
DC24V specification: max. 160mA
AC/DC 24V 0.5 seconds No corrosive or flammable gases, and no heavy dust. Waterproof and dustproof structure available
Approximately 250g, 48X96X100mm (length x width x depth) Between measurement terminal and ground: AC 1,000V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicator AE500-Part Number-AE500K01-3*NNNN-N1/A

AE500K01-3*NNNN-N1/A

Available upon quote No alarm function No alarm function No function No function ・CE marking compliant
・Compliant with UL/cUL standards
・RCM mark compliant
Black tone No communication function Approx. 0.2μV/Ω (Thermocouple input) Approximately 0.01 [%/Ω] of reading value (resistance temperature detector input)
*Maximum within 10Ω per wire
Power outages of 20msec or less will not affect operation.
*Any further power outage will result in the initial state.
Approximately 1MΩ K (JIS/IEC) 0~200℃ Between measurement terminal and ground DC 500V 20MΩ or more ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (approximately 10 years) Downscale (RTD input)
*Alarm output is ON
Upscale No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
When inputting temperature: -1,999~9,999℃ or -199.9~999.9℃ 45~85%RH 0~50℃ AC24V specifications: max. 5VA
DC24V specification: max. 160mA
AC/DC 24V 0.5 seconds No corrosive or flammable gases, and no heavy dust. Waterproof and dustproof structure available
Approximately 250g, 48X96X100mm (length x width x depth) Between measurement terminal and ground: AC 1,000V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicator AE500-Part Number-AE500K01-3*NNNN-5N/N

AE500K01-3*NNNN-5N/N

Available upon quote No alarm function No alarm function No function No function ・CE marking compliant
・Compliant with UL/cUL standards
・RCM mark compliant
White tone RS-485 Approx. 0.2μV/Ω (Thermocouple input) Approximately 0.01 [%/Ω] of reading value (resistance temperature detector input)
*Maximum within 10Ω per wire
Power outages of 20msec or less will not affect operation.
*Any further power outage will result in the initial state.
Approximately 1MΩ K (JIS/IEC) 0~200℃ Between measurement terminal and ground DC 500V 20MΩ or more ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (approximately 10 years) Downscale (RTD input)
*Alarm output is ON
Upscale No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
When inputting temperature: -1,999~9,999℃ or -199.9~999.9℃ 45~85%RH 0~50℃ AC24V specifications: max. 5VA
DC24V specification: max. 160mA
AC/DC 24V 0.5 seconds No corrosive or flammable gases, and no heavy dust. No waterproof/dustproof structure
Approximately 250g, 48X96X100mm (length x width x depth) Between measurement terminal and ground: AC 1,000V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicator AE500-Part Number-AE500K01-3*NNNN-5N/A

AE500K01-3*NNNN-5N/A

Available upon quote No alarm function No alarm function No function No function ・CE marking compliant
・Compliant with UL/cUL standards
・RCM mark compliant
Black tone RS-485 Approx. 0.2μV/Ω (Thermocouple input) Approximately 0.01 [%/Ω] of reading value (resistance temperature detector input)
*Maximum within 10Ω per wire
Power outages of 20msec or less will not affect operation.
*Any further power outage will result in the initial state.
Approximately 1MΩ K (JIS/IEC) 0~200℃ Between measurement terminal and ground DC 500V 20MΩ or more ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (approximately 10 years) Downscale (RTD input)
*Alarm output is ON
Upscale No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
When inputting temperature: -1,999~9,999℃ or -199.9~999.9℃ 45~85%RH 0~50℃ AC24V specifications: max. 5VA
DC24V specification: max. 160mA
AC/DC 24V 0.5 seconds No corrosive or flammable gases, and no heavy dust. No waterproof/dustproof structure
Approximately 250g, 48X96X100mm (length x width x depth) Between measurement terminal and ground: AC 1,000V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicator AE500-Part Number-AE500K01-3*NNNN-51/N

AE500K01-3*NNNN-51/N

Available upon quote No alarm function No alarm function No function No function ・CE marking compliant
・Compliant with UL/cUL standards
・RCM mark compliant
White tone RS-485 Approx. 0.2μV/Ω (Thermocouple input) Approximately 0.01 [%/Ω] of reading value (resistance temperature detector input)
*Maximum within 10Ω per wire
Power outages of 20msec or less will not affect operation.
*Any further power outage will result in the initial state.
Approximately 1MΩ K (JIS/IEC) 0~200℃ Between measurement terminal and ground DC 500V 20MΩ or more ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (approximately 10 years) Downscale (RTD input)
*Alarm output is ON
Upscale No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
When inputting temperature: -1,999~9,999℃ or -199.9~999.9℃ 45~85%RH 0~50℃ AC24V specifications: max. 5VA
DC24V specification: max. 160mA
AC/DC 24V 0.5 seconds No corrosive or flammable gases, and no heavy dust. Waterproof and dustproof structure available
Approximately 250g, 48X96X100mm (length x width x depth) Between measurement terminal and ground: AC 1,000V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicator AE500-Part Number-AE500K01-3*NNNN-51/A

AE500K01-3*NNNN-51/A

Available upon quote No alarm function No alarm function No function No function ・CE marking compliant
・Compliant with UL/cUL standards
・RCM mark compliant
Black tone RS-485 Approx. 0.2μV/Ω (Thermocouple input) Approximately 0.01 [%/Ω] of reading value (resistance temperature detector input)
*Maximum within 10Ω per wire
Power outages of 20msec or less will not affect operation.
*Any further power outage will result in the initial state.
Approximately 1MΩ K (JIS/IEC) 0~200℃ Between measurement terminal and ground DC 500V 20MΩ or more ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (approximately 10 years) Downscale (RTD input)
*Alarm output is ON
Upscale No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
When inputting temperature: -1,999~9,999℃ or -199.9~999.9℃ 45~85%RH 0~50℃ AC24V specifications: max. 5VA
DC24V specification: max. 160mA
AC/DC 24V 0.5 seconds No corrosive or flammable gases, and no heavy dust. Waterproof and dustproof structure available
Approximately 250g, 48X96X100mm (length x width x depth) Between measurement terminal and ground: AC 1,000V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicator AE500-Part Number-AE500K01-3*HNNN-NN/N

AE500K01-3*HNNN-NN/N

Available upon quote Upper limit input value alarm No alarm function No function No function ・CE marking compliant
・Compliant with UL/cUL standards
・RCM mark compliant
White tone No communication function Approx. 0.2μV/Ω (Thermocouple input) Approximately 0.01 [%/Ω] of reading value (resistance temperature detector input)
*Maximum within 10Ω per wire
Power outages of 20msec or less will not affect operation.
*Any further power outage will result in the initial state.
Approximately 1MΩ K (JIS/IEC) 0~200℃ Between measurement terminal and ground DC 500V 20MΩ or more ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (approximately 10 years) Downscale (RTD input)
*Alarm output is ON
Upscale No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
When inputting temperature: -1,999~9,999℃ or -199.9~999.9℃ 45~85%RH 0~50℃ AC24V specifications: max. 5VA
DC24V specification: max. 160mA
AC/DC 24V 0.5 seconds No corrosive or flammable gases, and no heavy dust. No waterproof/dustproof structure
Approximately 250g, 48X96X100mm (length x width x depth) Between measurement terminal and ground: AC 1,000V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicator AE500-Part Number-AE500K01-3*HNNN-NN/A

AE500K01-3*HNNN-NN/A

Available upon quote Upper limit input value alarm No alarm function No function No function ・CE marking compliant
・Compliant with UL/cUL standards
・RCM mark compliant
Black tone No communication function Approx. 0.2μV/Ω (Thermocouple input) Approximately 0.01 [%/Ω] of reading value (resistance temperature detector input)
*Maximum within 10Ω per wire
Power outages of 20msec or less will not affect operation.
*Any further power outage will result in the initial state.
Approximately 1MΩ K (JIS/IEC) 0~200℃ Between measurement terminal and ground DC 500V 20MΩ or more ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (approximately 10 years) Downscale (RTD input)
*Alarm output is ON
Upscale No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
When inputting temperature: -1,999~9,999℃ or -199.9~999.9℃ 45~85%RH 0~50℃ AC24V specifications: max. 5VA
DC24V specification: max. 160mA
AC/DC 24V 0.5 seconds No corrosive or flammable gases, and no heavy dust. No waterproof/dustproof structure
Approximately 250g, 48X96X100mm (length x width x depth) Between measurement terminal and ground: AC 1,000V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of RKC INSTRUMENT


View more products of RKC INSTRUMENT

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree