All Categories
History
Response Rate
100.0%
Response Time
26.1hours
Relatively Fast Response
Product
AC electronic voltmeter 2ch GVT-427BHandling Company
TEXIO TECHNOLOGY CORPORATIONCategories
Image | Part Number | Price (excluding tax) | Power supply voltage | Weight | Measurement voltage range (12 ranges) | Power consumption | Distortion rate (at 1kHz) | Maximum dimensions | Maximum input voltage (DC+AC peak) | Indication accuracy | External dimensions | Frequency characteristics (Reference: 1kHz) | Input capacity | Input fluctuation | Input impedance | Usage environment | Meter display value | Meter instructions | Fuse | Decibel scale | Number of channels | Chassis - GND | AC output voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GVT-427B |
Available upon quote |
AC100V (90V~110V),50/60Hz |
Approximately 2.8kg |
Voltage: 300μV, 1mV, 3mV, 10mV, 30mV, |
Max 10VA (5.0W) |
≦2% at full scale |
131.9 (W) x212.9 (H) x291.4 (D) mm |
300V (300μV~1V range) |
Within ±3% of full scale (1kHz standard) |
131.9 (W) x196 (H) x250 (D) mm |
300μV range: 10Hz~500kHz±10% |
50pF or less |
Within ±0.5% of full scale for fluctuations of rated power supply voltage ±10% |
Approximately 1MΩ |
Indoor use, altitude below 2000m, installation category II, pollution degree 2 |
VrmsSIN wave,dB:0dB=1V |
2 stitch instructions (black/red) |
100V: 0.3A, 250V (time lag type) |
-20~+1dB (0dB=1V), |
2 |
0.1Ω or 100kΩ |
0.1V rms±10% each range (1kHz, no load) |
Reviews shown here are reviews of companies.