■Electronic load operation function

Our FCT series is equipped as standard with a current sweep operation function that is essential for I-V characteristic evaluation. You can also choose from various resistance measurement functions (current interruption method, fixed AC impedance method, AC 4-terminal method (AC superimposed resistance meter) to measure membrane resistance.

■Long-term stability of the device

It is very important to know the durability performance of the battery when evaluating fuel cells. Our FCT series has excellent condition stability. The above data shows the stability of each test condition when operating under the same conditions for a long time (18 hours). It boasts excellent stability with dew point temperature ripple of 0.4℃, gas temperature ripple of 0.2℃, and back pressure ripple of 0.2kPa.

■Constant back pressure control

Differences in piping volumes and flow rate settings for the anode and cathode devices may cause differential pressure within the battery, which may damage the MEA. Our FCT series has a constant differential pressure control function that automatically maintains and controls the differential pressure at a constant level even when testing with different gas flow rates. (Optional) Additionally, the FCT series can be equipped with a fixed gradient function for backpressure control to prevent damage to the MEA due to sudden changes in backpressure. (Standard feature)

■Excellent dew point transient characteristics

Although our FCT series is a simple bubbler type, it achieves high stability and highly responsive dew point control. Above data: When equipped with humidifying water external circulation cooling system (optional)

■Features

・Ideal for basic research full-size single cell evaluation ・All-in-one, compact design ・Excellent stability and followability (back pressure, flow rate, temperature, humidity) ・Fully automatic unmanned operation possible ・Internal resistance measurement equipment can be selected (IR, AC impedance resistance meter, etc.) ・Easy to create test programs ・All operations, monitoring, and data settings can be performed from a PC. ・Automatic leak check function standard equipment

■Options

・Heat exchange bubbler cooling function ・Constant back pressure control function ・Gas blend function ・High precision pressure sensor ・FC outlet dew point meter

  • Product

    Fuel cell evaluation device FCT20

Share this product


120+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Fuel cell evaluation device FCT20

Image Part Number Price (excluding tax) Dew point control temperature Electronic load device Back pressure control Maximum load, current, voltage Resistance measurement method Size Safety features Refrigerant temperature Refrigerant flow rate Refrigerant Power range Cell voltage monitor standard number of channels Cell stack temperature control Gas temperature Gas flow rate cathode N2 Gas flow rate Cathode Air Gas flow rate Anode N2 Gas flow rate Anode H2 Gas flow rate Gas humidification method FC bypass Dry line Others
Fuel cell evaluation device FCT20-Part Number-FCT20

FCT20

Available upon quote

Room temperature +10℃~90℃ (Option: 120℃)

Manufactured by Kikusui Electronics Option: 1,000A, compatible with negative potential

Open to atmosphere, 5-300Kpa.G

Equipment specifications: 1,980W, 396A, 0.1-20V (can be changed upon request)

AC impedance method (optional measurement of each cell is also available)

Standard: 950x1,900 (including hood: 2,100) x2,100

Abnormal stop with various interlocks, hydrogen detector, flashback preventer, double temperature overheating, emergency nitrogen purge, manual emergency stop, water leak sensor, etc.

Room temperature +10℃~110℃

0.1~3L/min

Standard/Option: Pure water/LLC

0-2kW

10 (Optional channels can be added)

Circulating water type

Room temperature +10℃~120℃ (Option: 150℃)

0.2-10NL/min

0.8-40NL/min (MAX80NL/min)

0.1-5NL/min

0.3-15NL/min (MAX30NL/min)

Option: Multi-stage control allows expansion of flow rate control range

Circulating bubbler

Yes

Yes

Exhaust gas condenser, constant differential pressure control, FC inlet dew point meter, data collection, etc.

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Fuel Cells Products

Other products of Enoa Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Enoa Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

24.8hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree