Water-equivalent material micro "scintillation detector" with detector size φ1mm EXRADIN W2 scintillator-REF 72435 (1×3)
Water-equivalent material micro "scintillation detector" with detector size φ1mm EXRADIN W2 scintillator-Chiyoda Technol Co., Ltd.

Water-equivalent material micro "scintillation detector" with detector size φ1mm EXRADIN W2 scintillator
Chiyoda Technol Co., Ltd.

Chiyoda Technol Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

55.7hours


About This Product

It enables dose measurement of small radiation fields without any disturbance caused by the detector. EXRADIN W2 is made of water-equivalent plastic material, and its tiny detector is φ1mm in size. The scintillation light from W2 is detected by the attached MAX-SD and the dose value is derived. It is almost unaffected by temperature and pressure, and since the detector is made of water-equivalent material, it does not disturb the measurement field. It is also possible to output measured values ​​in analog form from MAX-SD, and it can also be applied to scanning measurements. Ultra-small detector equivalent to water

■Excellent measurement accuracy in small radiation fields

Unlike other detectors, the EXRADIN W2 scintillator is constructed from a water-equivalent material and therefore does not have any effects within the beam due to the detector itself. This enables more accurate dosimetry in small radiation fields.

■High resolution

This system features a 1mm x 1mm scintillation fiber and provides high resolution measurements, such as for small field characterization.

■Built-in correction function

6. By using MAX SD, a unit that detects scintillation light and processes signals, scanning and point doses can be measured. You can also access MAX SD from your PC via the web interface.

■Excellent features

AAPM/IAEA 483 states that scintillators are the only detectors with kQ1.000. Therefore, W2 is the perfect detector for measurements in stereotactic radiotherapy. Water-equivalent material, waterproof construction, built-in correction, scanning and point dosimetry capabilities, and two types of user-replaceable fibers (1 x 1 mm, 1 x 3 mm) available. Furthermore, it is characterized by low dose rate dependence, temperature dependence, and energy dependence. By outputting analog signals corrected for Cerenkov effects, it is possible to connect to a water phantom system for scanning measurements.

  • Product

    Water-equivalent material micro "scintillation detector" with detector size φ1mm EXRADIN W2 scintillator

Share this product


190+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

2 Models of Water-equivalent material micro "scintillation detector" with detector size φ1mm EXRADIN W2 scintillator

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Charge collection Trigger Charge collection Timed Charge collection Continuous Weight Patent Material Sensitivity decrease Material Optical fiber Minimum bending radius Material Optical fiber Material scintillating fiber Material scintillator physical density Collection volume fiber optic Collection volume scintillating fiber Collection volume scintillator housing Conditions of use Humidity Conditions of use Temperature Conditions of use Atmospheric pressure Point dose measurement mode - display range Rate Point dose measurement mode - display range Charge Scanning mode - display range Rate Size Interface output Interface input Standard
Water-equivalent material micro "scintillation detector" with detector size φ1mm EXRADIN W2 scintillator-Part Number-REF 72435 (1×3)

REF 72435 (1×3)

Available upon quote

Automatic measurements based on user-configured thresholds (Threshold: 0.01~100pA)

Measurement time setting by user (range: 0.5~9999.9 seconds, 0.1 second increments)

Continuous measurement with manual stop

3.6kg

US Patent No.8183534

~2%/kGy

3cm

PMMA+Polystyrene jacket

Polystyrene + ABS plastic protective film, polyimide stem

1.05g/㎤

Inner diameter φ1.0mm, outer diameter φ2.2mm, length 4m

W2-1×1: φ1.0mm×L1.0mm, W2-1×3: φ1.0mm×L3.0mm

Φ2.8mm×L42mm

20~80%

15~30℃

650~770mmHg

-4.8pA~1.2nA, resolution 1fA

0.000pC~999.9μC, resolution 1fC

-4.8pA~100pA, resolution 1fA

21×16×9cm

Analog current (2-Lug triaxial BNC)

Scintillation light (SMA-905)

IEC 60601-1 CE0413 standard

Water-equivalent material micro "scintillation detector" with detector size φ1mm EXRADIN W2 scintillator-Part Number-REF 72436 (1×1)

REF 72436 (1×1)

Available upon quote

Automatic measurements based on user-configured thresholds (Threshold: 0.01~100pA)

Measurement time setting by user (range: 0.5~9999.9 seconds, 0.1 second increments)

Continuous measurement with manual stop

3.6kg

US Patent No.8183534

~2%/kGy

3cm

PMMA+Polystyrene jacket

Polystyrene + ABS plastic protective film, polyimide stem

1.05g/㎤

Inner diameter φ1.0mm, outer diameter φ2.2mm, length 4m

W2-1×1: φ1.0mm×L1.0mm, W2-1×3: φ1.0mm×L3.0mm

Φ2.8mm×L42mm

20~80%

15~30℃

650~770mmHg

-4.8pA~1.2nA, resolution 1fA

0.000pC~999.9μC, resolution 1fC

-4.8pA~100pA, resolution 1fA

21×16×9cm

Analog current (2-Lug triaxial BNC)

Scintillation light (SMA-905)

IEC 60601-1 CE0413 standard

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Scintillators Products

Other products of Chiyoda Technol Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Chiyoda Technol Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

55.7hrs


Company Review

5.0
  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree