Gas detection warning device indicating unit warning unit-V3-HV
Gas detection warning device indicating unit warning unit-New Cosmos Electric

Gas detection warning device indicating unit warning unit
New Cosmos Electric


About This Product

It is an alarm unit, a guide unit that can compose a flexible system in combination with various gas detection portions. In addition to the lamp and buzzer, the digital bar graph of the three -color LED display of the indicating unit will inform you of the alarm state in an easy -to -understand manner. Product features ・ Equipped with maintenance mode that can stop warning output to the outside during maintenance, one -man maintenance is also possible ・ It is also possible to replace the existing company alarm ・ The switch part of the instruction meter unit is covered to prevent erroneous operations

  • Product

    Gas detection warning device indicating unit warning unit




*Please note that we may not be able to accommodate sample requests.

10 Models of Gas detection warning device indicating unit warning unit

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Alarm setting value Detection principle Detection range External dimensions (excluding protrusions) External output (analog output) External output (contact output) Gas concentration display Gas concentration display (50 division) Mass (when a single case is incorporated) Used power supply Used temperature and humidity range power consumption
Gas detection warning device indicating unit warning unit-Part Number-V3-HV

V3-HV

Available upon quote Optional setting can be made within the detection range Heat ray type semiconductor According to the detection unit specification W36 x H144 x D70mm DC4-20ma 1C -voltage (AC100V / 1A resistance load) 1A is 1A Flashy gas (LPG, methane, etc.) Three -color LED Burgraph Meter Approximately 600g (standard) DC24V ± 10%(but 24V ± 6V depending on the detection unit to be connected) -10 ~+40 ° C, 10-90%RH (sudden temperature change, no condensation) Approximately 4.0W (excluding power consumption when connecting suction type detection unit)
Gas detection warning device indicating unit warning unit-Part Number-V3-HI

V3-HI

Available upon quote Optional setting can be made within the detection range Heat ray type semiconductor According to the detection unit specification W36 x H144 x D70mm DC4-20ma 1C -voltage (AC100V / 1A resistance load) 1A is 1A Flashy gas (LPG, methane, etc.) Three -color LED Burgraph Meter Approximately 600g (standard) DC24V ± 10%(but 24V ± 6V depending on the detection unit to be connected) -10 ~+40 ° C, 10-90%RH (sudden temperature change, no condensation) Approximately 4.0W (excluding power consumption when connecting suction type detection unit)
Gas detection warning device indicating unit warning unit-Part Number-V3-CV

V3-CV

Available upon quote Optional setting can be made within the detection range Contact burning ceremony According to the detection unit specification W36 x H144 x D70mm DC4-20ma 1C -voltage (AC100V / 1A resistance load) 1A is 1A Flashy gas (LPG, methane, etc.) Three -color LED Burgraph Meter Approximately 600g (standard) DC24V ± 10%(but 24V ± 6V depending on the detection unit to be connected) -10 ~+40 ° C, 10-90%RH (sudden temperature change, no condensation) Approximately 4.0W (excluding power consumption when connecting suction type detection unit)
Gas detection warning device indicating unit warning unit-Part Number-V3-ci

V3-ci

Available upon quote Optional setting can be made within the detection range Contact burning ceremony According to the detection unit specification W36 x H144 x D70mm DC4-20ma 1C -voltage (AC100V / 1A resistance load) 1A is 1A Flashy gas (LPG, methane, etc.) Three -color LED Burgraph Meter Approximately 600g (standard) DC24V ± 10%(but 24V ± 6V depending on the detection unit to be connected) -10 ~+40 ° C, 10-90%RH (sudden temperature change, no condensation) Approximately 4.0W (excluding power consumption when connecting suction type detection unit)
Gas detection warning device indicating unit warning unit-Part Number-V3-TV

V3-TV

Available upon quote Optional setting can be made within the detection range Body heat conduction formula According to the detection unit specification W36 x H144 x D70mm DC4-20ma 1C -voltage (AC100V / 1A resistance load) 1A is 1A H2/Helium/Argon/CO2/CH4 Three -color LED Burgraph Meter Approximately 600g (standard) DC24V ± 10%(but 24V ± 6V depending on the detection unit to be connected) -10 ~+40 ° C, 10-90%RH (sudden temperature change, no condensation) Approximately 4.0W (excluding power consumption when connecting suction type detection unit)
Gas detection warning device indicating unit warning unit-Part Number-V3-Ti

V3-Ti

Available upon quote Optional setting can be made within the detection range Body heat conduction formula According to the detection unit specification W36 x H144 x D70mm DC4-20ma 1C -voltage (AC100V / 1A resistance load) 1A is 1A H2/Helium/Argon/CO2/CH4 Three -color LED Burgraph Meter Approximately 600g (standard) DC24V ± 10%(but 24V ± 6V depending on the detection unit to be connected) -10 ~+40 ° C, 10-90%RH (sudden temperature change, no condensation) Approximately 4.0W (excluding power consumption when connecting suction type detection unit)
Gas detection warning device indicating unit warning unit-Part Number-V3-D

V3-D

Available upon quote Optional setting can be made within the detection range Fixed potential plateau According to the detection unit specification W36 x H144 x D70mm DC4-20ma 1C -voltage (AC100V / 1A resistance load) 1A is 1A Various semiconductor materials gas/Various toxic gas Three -color LED Burgraph Meter Approximately 600g (standard) DC24V ± 10%(but 24V ± 6V depending on the detection unit to be connected) -10 ~+40 ° C, 10-90%RH (sudden temperature change, no condensation) Approximately 4.0W (excluding power consumption when connecting suction type detection unit)
Gas detection warning device indicating unit warning unit-Part Number-V3-O

V3-O

Available upon quote Optional setting can be made within the detection range Galvani battery According to the detection unit specification W36 x H144 x D70mm DC4-20ma 1C -voltage (AC100V / 1A resistance load) 1A is 1A oxygen Three -color LED Burgraph Meter Approximately 600g (standard) DC24V ± 10%(but 24V ± 6V depending on the detection unit to be connected) -10 ~+40 ° C, 10-90%RH (sudden temperature change, no condensation) Approximately 4.0W (excluding power consumption when connecting suction type detection unit)
Gas detection warning device indicating unit warning unit-Part Number-V3-M

V3-M

Available upon quote Optional setting can be made within the detection range Depending on the specification of the detection unit According to the detection unit specification W36 x H144 x D70mm DC4-20ma 1C -voltage (AC100V / 1A resistance load) 1A is 1A Depending on the specification of the detection unit Three -color LED Burgraph Meter Approximately 600g (standard) DC24V ± 10%(but 24V ± 6V depending on the detection unit to be connected) -10 ~+40 ° C, 10-90%RH (sudden temperature change, no condensation) Approximately 5.0W (excluding power consumption when connecting to detection department)
Gas detection warning device indicating unit warning unit-Part Number-Vas

Vas

Available upon quote - - - W36 x H144 x D70mm - - - - Approximately 600g (standard) DC24V ± 10% -10 ~+40 ° C, 10-90 % RH Approximately 3.5W (power supply 24V, warning)

Click on the part number for more information about each product

Other products of New Cosmos Electric


View more products of New Cosmos Electric

About Company Handling This Product

New Cosmos Electric

  • Japan
  • 467 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree