All Categories
History
Product
NDIR non -dispersed infrared light carbon dioxide detection alarmHandling Company
New Cosmos ElectricImage | Part Number | Price (excluding tax) | Detection principle | Gas to be detected | Detection range | Repetition | Operating temperature limit | Used humidity range | Alarm setting value | Alarm accuracy | Alarm display | A warning delay | Alarm mode | power supply | power consumption | structure | size | weight | Paint color | Conjunction |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
IRC-630 |
Available upon quote |
Non -dispersed infrared light |
carbon dioxide |
0 ~ 5vol % 0-2.5vol % 0 to 1Vol % 0 ~ 5000pm0 to 2500PPM |
± 2 % of full scale |
0 to 40 ° C |
35-95 % RH (but not condensation) |
Violation can be set within the measurement range (two -stage warning type is also possible, but alarm output 1A) |
± 25%or less of the alarm setting value (under the same condition) |
Red lamp lighting and buzzer sound when the set value is exceeded |
Within 20 seconds (with 1.6 times gas of the alarm setting) |
Automatic return (self -maintenance is also possible) |
AC100V ± 10 % 50/60Hz |
Approximately 30va |
Wall -mounted drip -proof structure pump suction type |
W200 x H390 x D113mm (excluding protrusions) |
Approximately 6kg |
Mancel 5y7/1 |
RC1/4 |