Product Image | Part Number | Price (excluding tax) | Cooling method | Current (100VAC) | Efficiency | Frequency range | Holding time (100VAC) | Insulation resistance | Maximum current | Maximum input variation | Maximum load fluctuation | Maximum power | Maximum temperature fluctuation | Minimum current | Noise terminal voltage | Operating humidity | Operating temperature | Overcurrent protection | Overvoltage protection | Parallel operation | Rated voltage | Ripple noise | Safety standards | Series operation | Shockproof | Storage humidity | Storage temperature | Surge current (100/200VAC) | Vibration resistance | Voltage range | Voltage setting accuracy | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KWD5-1212 |
Available upon quote | Natural air cooling | 0.2A | 69% | 47~440Hz | 17ms (5W, Ta=25℃) | 100MΩ or more (between output and FG: 500VDC, 25℃, 70%RH) | 0.22A | 60mV | 600mV | 5.3W | 120mV | 0A | VCCI-A, FCC-B, VDE-B compliant | 30~90%RH (no condensation) | -10~70℃ (-10℃: 80% 0~50℃: 100% 70℃: 25%) | 105%~ | 110%~ | None | -12~+12VDC | 150mVp-p | UL60950-1, CSA C22.2 No.60950-1, EN60950 certifications | Can be | 490.3m/s2 or less Impact time 11±5ms 3 times in 6 directions | 20~95%RH (no condensation) | −30~85℃ | 15/30A (Ta=25℃) | When not operating, 10~55Hz (sweep 1 minute), amplitude 1.65mm (maximum 98.1m/s2) constant, 1 hour each in XYZ directions | AC85~265V or DC110~340V | Fixed ±5% (Max) |
Between input and output: 3kVAC (20mA) for 1 minute, between input and FG: 2kVAC (20mA) for 1 minute Between output and FG: 500VAC (100mA) for 1 minute |
|
KWD5-1515 |
Available upon quote | Natural air cooling | 0.2A | 69% | 47~440Hz | 17ms (5W, Ta=25℃) | 100MΩ or more (between output and FG: 500VDC, 25℃, 70%RH) | 0.18A | 75mV | 750mV | 5.4W | 150mV | 0A | VCCI-A, FCC-B, VDE-B compliant | 30~90%RH (no condensation) | -10~70℃ (-10℃: 80% 0~50℃: 100% 70℃: 25%) | 105%~ | 110%~ | None | -15~+15VDC | 150mVp-p | UL60950-1, CSA C22.2 No.60950-1, EN60950 certifications | Can be | 490.3m/s2 or less Impact time 11±5ms 3 times in 6 directions | 20~95%RH (no condensation) | −30~85℃ | 15/30A (Ta=25℃) | When not operating, 10~55Hz (sweep 1 minute), amplitude 1.65mm (maximum 98.1m/s2) constant, 1 hour each in XYZ directions | AC85~265V or DC110~340V | Fixed ±5% (Max) |
Between input and output: 3kVAC (20mA) for 1 minute, between input and FG: 2kVAC (20mA) for 1 minute Between output and FG: 500VAC (100mA) for 1 minute |
|
KWD10-1212 |
Available upon quote | Natural air cooling | 0.3A | 72% | 47~440Hz | 17ms (10W, Ta=25℃) | 100MΩ or more (between output and FG: 500VDC, 25℃, 70%RH) | 0.45A | 60mV | 600mV | 10.8W | 120mV | 0A | VCCI-A, FCC-B, VDE-B compliant | 30~90%RH (no condensation) | -10~70℃ (-10℃: 80% 0~50℃: 100% 70℃: 25%) | 105%~ | 110%~ | None | -12~+12VDC | 150mVp-p | UL60950-1, CSA C22.2 No.60950-1, EN60950 certifications | Can be | 490.3m/s2 or less Impact time 11±5ms 3 times in 6 directions | 20~95%RH (no condensation) | −30~85℃ | 15/30A (Ta=25℃) | When not operating, 10~55Hz (sweep 1 minute), amplitude 1.65mm (maximum 98.1m/s2) constant, 1 hour each in XYZ directions | AC85~265V or DC110~340V | Fixed ±5% (Max) |
Between input and output: 3kVAC (20mA) for 1 minute, between input and FG: 2kVAC (20mA) for 1 minute Between output and FG: 500VAC (100mA) for 1 minute |
|
KWD10-1515 |
Available upon quote | Natural air cooling | 0.3A | 72% | 47~440Hz | 17ms (10W, Ta=25℃) | 100MΩ or more (between output and FG: 500VDC, 25℃, 70%RH) | 0.36A | 75mV | 750mV | 10.8W | 150mV | 0A | VCCI-A, FCC-B, VDE-B compliant | 30~90%RH (no condensation) | -10~70℃ (-10℃: 80% 0~50℃: 100% 70℃: 25%) | 105%~ | 110%~ | None | -15~+15VDC | 150mVp-p | UL60950-1, CSA C22.2 No.60950-1, EN60950 certifications | Can be | 490.3m/s2 or less Impact time 11±5ms 3 times in 6 directions | 20~95%RH (no condensation) | −30~85℃ | 15/30A (Ta=25℃) | When not operating, 10~55Hz (sweep 1 minute), amplitude 1.65mm (maximum 98.1m/s2) constant, 1 hour each in XYZ directions | AC85~265V or DC110~340V | Fixed ±5% (Max) |
Between input and output: 3kVAC (20mA) for 1 minute, between input and FG: 2kVAC (20mA) for 1 minute Between output and FG: 500VAC (100mA) for 1 minute |
|
KWD15-1212 |
Available upon quote | Natural air cooling | 0.4A | 75% | 47~440Hz | 17ms (15W, Ta=25℃) | 100MΩ or more (between output and FG: 500VDC, 25℃, 70%RH) | 0.65A | 60mV | 600mV | 15.6W | 120mV | 0A | VCCI-A, FCC-B, VDE-B compliant | 30~90%RH (no condensation) | -10~70℃ (-10℃: 80% 0~50℃: 100% 70℃: 25%) | 105%~ | 110%~ | None | -12~+12VDC | 150mVp-p | UL60950-1, CSA C22.2 No.60950-1, EN60950 certifications | Can be | 490.3m/s2 or less Impact time 11±5ms 3 times in 6 directions | 20~95%RH (no condensation) | −30~85℃ | 20/40A (Ta=25℃) | When not operating, 10~55Hz (sweep 1 minute), amplitude 1.65mm (maximum 98.1m/s2) constant, 1 hour each in XYZ directions | AC85~265V or DC110~340V | Fixed ±5% (Max) |
Between input and output: 3kVAC (20mA) for 1 minute, between input and FG: 2kVAC (20mA) for 1 minute Between output and FG: 500VAC (100mA) for 1 minute |
|
KWD15-1515 |
Available upon quote | Natural air cooling | 0.4A | 75% | 47~440Hz | 17ms (15W, Ta=25℃) | 100MΩ or more (between output and FG: 500VDC, 25℃, 70%RH) | 0.52A | 75mV | 750mV | 15.6W | 150mV | 0A | VCCI-A, FCC-B, VDE-B compliant | 30~90%RH (no condensation) | -10~70℃ (-10℃: 80% 0~50℃: 100% 70℃: 25%) | 105%~ | 110%~ | None | -15~+15VDC | 150mVp-p | UL60950-1, CSA C22.2 No.60950-1, EN60950 certifications | Can be | 490.3m/s2 or less Impact time 11±5ms 3 times in 6 directions | 20~95%RH (no condensation) | −30~85℃ | 20/40A (Ta=25℃) | When not operating, 10~55Hz (sweep 1 minute), amplitude 1.65mm (maximum 98.1m/s2) constant, 1 hour each in XYZ directions | AC85~265V or DC110~340V | Fixed ±5% (Max) |
Between input and output: 3kVAC (20mA) for 1 minute, between input and FG: 2kVAC (20mA) for 1 minute Between output and FG: 500VAC (100mA) for 1 minute |
Click on the part number for more information about each product