Product
Board type digital indicatorHandling Company
Sanyu Electronics Industry Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | A/D sampling | Applicable converter | Bridge power supply | CHECK | Decimal point display | Effect of temperature Zero point | Effects of temperature Sensitivity | External control function A/Z | External control function A/Z OFF | External control function HOLD | External control function LOCK | External control function ZERO | Input noise | Input range | Key switch function A/Z OFF/▲ | Key switch function A/Z/◀ | Key switch function CHECK | Key switch function ENTER | Key switch function FUNC. | Key switch function ZERO | Load display Display range | Load display Over display | Load display indicator | Nonlinearity | Number of views | Open collector output signal ERROR | Open collector output signal RUN | RS-232C interface baud rate | Status display | Zero point adjustment range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Csd581-74 |
Available upon quote | 100 times/s | Up to 4 strain gauge transducers (350Ω) can be connected | Within DC10V±0.5V120mA (DC2.5V switchable) With remote sensing | Approx. 0.3mV/V (can be set in the range of approx. 0.1mV/V to 1.5mV/V in steps of 0.1mV/V) | No display, 10^1, 10^2, 10^3, 10^4 switchable | ±0.4μV/℃ (input conversion, when F.S. is set at 0.3mV/V~3.1mV/V input) | ±0.003%F.S./℃ (input conversion, when F.S. is set at 0.3mV/V~3.1mV/V input) | Same as A/Z key | Same as A/Z OFF key*Valid once for pulse input, pulse width 100ms or more | Display, RS-232C interface hold | Key operation prohibited *Enabled during input at higher level input, short-circuited for 100ms or more | Same as ZERO key | ±0.3μVp-p or less (with digital filter and stabilization filter default settings) | F.S. can be set with 0.2mV/V~3.1mV/V input (when bridge power supply DC10V) | Tare cancellation/setting value increment | Tare weight subtraction/set value carry | Check value on/off | Entry key | Function mode switching | Zero set | -1,000~11,000 (×2, ×5, ×10 possible) | -OL" when minus over, "OL" when plus over | Red 7 segment LED, character height 8mm, 5 digits | Within 0.01% F.S. (when F.S. is set at 0.3mV/V~3.1mV/V input) | 4 times/s (20 times/s, 50 times/s switchable) | ON when various errors occur Vce=DC30V, Ic=DC30mA MAX | ON in instrument measurement mode | Select from 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400bps | RUN, A/Z, LOCK, HOLD, CHECK | -0.1mV/V~2.4mV/V |
![]() |
Csd581-15 |
Available upon quote | 100 times/s | Up to 4 strain gauge transducers (350Ω) can be connected | Within DC10V±0.5V120mA (DC2.5V switchable) With remote sensing | Approx. 0.3mV/V (can be set in the range of approx. 0.1mV/V to 1.5mV/V in steps of 0.1mV/V) | No display, 10^1, 10^2, 10^3, 10^4 switchable | ±0.4μV/℃ (input conversion, when F.S. is set at 0.3mV/V~3.1mV/V input) | ±0.003%F.S./℃ (input conversion, when F.S. is set at 0.3mV/V~3.1mV/V input) | - | - | - | - | - | ±0.3μVp-p or less (with digital filter and stabilization filter default settings) | F.S. can be set with 0.2mV/V~3.1mV/V input (when bridge power supply DC10V) | Tare cancellation/setting value increment | Tare weight subtraction/set value carry | Check value on/off | Entry key | Function mode switching | Zero set | -1,000~11,000 (×2, ×5, ×10 possible) | -OL" when minus over, "OL" when plus over | Red 7 segment LED, character height 8mm, 5 digits | Within 0.01% F.S. (when F.S. is set at 0.3mV/V~3.1mV/V input) | 4 times/s (20 times/s, 50 times/s switchable) | ON when various errors occur Vce=DC30V, Ic=DC30mA MAX | ON in instrument measurement mode | - | RUN, A/Z, LOCK, HOLD, CHECK | -0.1mV/V~2.4mV/V |
Click on the part number for more information about each product