All Categories
History
Response Rate
100.0%
Response Time
84.1hours
Product
Board type digital indicatorHandling Company
Sanyu Electronics Industry Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Nonlinearity | Zero point adjustment range | Applicable converter | Number of views | Load display Display range | Load display indicator | Load display Over display | Status display | Effect of temperature Zero point | Effects of temperature Sensitivity | Decimal point display | Input range | Input noise | Bridge power supply | Key switch function ZERO | Key switch function FUNC. | Key switch function ENTER | Key switch function CHECK | Key switch function A/Z/◀ | Key switch function A/Z OFF/▲ | Open collector output signal RUN | Open collector output signal ERROR | CHECK | A/D sampling | External control function ZERO | External control function LOCK | External control function HOLD | External control function A/Z OFF | External control function A/Z | RS-232C interface baud rate |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Csd581-74 |
Available upon quote |
Within 0.01% F.S. (when F.S. is set at 0.3mV/V~3.1mV/V input) |
-0.1mV/V~2.4mV/V |
Up to 4 strain gauge transducers (350Ω) can be connected |
4 times/s (20 times/s, 50 times/s switchable) |
-1,000~11,000 (×2, ×5, ×10 possible) |
Red 7 segment LED, character height 8mm, 5 digits |
-OL" when minus over, "OL" when plus over |
RUN, A/Z, LOCK, HOLD, CHECK |
±0.4μV/℃ (input conversion, when F.S. is set at 0.3mV/V~3.1mV/V input) |
±0.003%F.S./℃ (input conversion, when F.S. is set at 0.3mV/V~3.1mV/V input) |
No display, 10^1, 10^2, 10^3, 10^4 switchable |
F.S. can be set with 0.2mV/V~3.1mV/V input (when bridge power supply DC10V) |
±0.3μVp-p or less (with digital filter and stabilization filter default settings) |
Within DC10V±0.5V120mA (DC2.5V switchable) With remote sensing |
Zero set |
Function mode switching |
Entry key |
Check value on/off |
Tare weight subtraction/set value carry |
Tare cancellation/setting value increment |
ON in instrument measurement mode |
ON when various errors occur Vce=DC30V, Ic=DC30mA MAX |
Approx. 0.3mV/V (can be set in the range of approx. 0.1mV/V to 1.5mV/V in steps of 0.1mV/V) |
100 times/s |
Same as ZERO key |
Key operation prohibited *Enabled during input at higher level input, short-circuited for 100ms or more |
Display, RS-232C interface hold |
Same as A/Z OFF key*Valid once for pulse input, pulse width 100ms or more |
Same as A/Z key |
Select from 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400bps |
|
Csd581-15 |
Available upon quote |
Within 0.01% F.S. (when F.S. is set at 0.3mV/V~3.1mV/V input) |
-0.1mV/V~2.4mV/V |
Up to 4 strain gauge transducers (350Ω) can be connected |
4 times/s (20 times/s, 50 times/s switchable) |
-1,000~11,000 (×2, ×5, ×10 possible) |
Red 7 segment LED, character height 8mm, 5 digits |
-OL" when minus over, "OL" when plus over |
RUN, A/Z, LOCK, HOLD, CHECK |
±0.4μV/℃ (input conversion, when F.S. is set at 0.3mV/V~3.1mV/V input) |
±0.003%F.S./℃ (input conversion, when F.S. is set at 0.3mV/V~3.1mV/V input) |
No display, 10^1, 10^2, 10^3, 10^4 switchable |
F.S. can be set with 0.2mV/V~3.1mV/V input (when bridge power supply DC10V) |
±0.3μVp-p or less (with digital filter and stabilization filter default settings) |
Within DC10V±0.5V120mA (DC2.5V switchable) With remote sensing |
Zero set |
Function mode switching |
Entry key |
Check value on/off |
Tare weight subtraction/set value carry |
Tare cancellation/setting value increment |
ON in instrument measurement mode |
ON when various errors occur Vce=DC30V, Ic=DC30mA MAX |
Approx. 0.3mV/V (can be set in the range of approx. 0.1mV/V to 1.5mV/V in steps of 0.1mV/V) |
100 times/s |
- | - | - | - | - | - |
Click on the part number for more information about each product